Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC INDIRA HATIA BIRBHUM | BIRBHUM | WEST BENGAL | ₹10.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹10.3 L+₹27,540 (2.75%)Rejected-Finance SAINTHIA BIRBHUM | SAINTHIA | BIRBHUM | WEST BENGAL | ₹10.3 L+₹27,540 (2.75%) | L2 | Rejected-Finance L2 |
| 3 | L3₹10.4 L+₹37,514 (3.75%)Rejected-Finance | ₹10.4 L+₹37,514 (3.75%) | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹20,121
Closing Date
9 Dec 2024, 1:00 pmClosed
Assistant Engineer PWD RESD
O/O the Assistant Engineer Rampurhat Electrical Sub Division
SITC of Air Conditioning System and allied EI work at GS ward Rampurhat Govt Medical College Hospital Birbhum
2024_WBPWD_772206_1
WBPWD/AE/RESD/eNIT-20/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Rampurhat Govt Medical College Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,121
Rampurhat
20 Jun 2025
22 Nov 2024
11 Dec 2024
22 Nov 2024
9 Dec 2024
25 Nov 2024
25 Nov 2024
Amount
Supply of 7.5 TR capacity Concealed type Split AC machines having Cooling Capacity of minimum 9000 BTU/hr with 3 nos. rotary compressor, 03 nos. IDU of rated power supply 230V-1Ph-50 Hz, 01 No. ODU of rated power supply 415V-3Ph-50 Hz. icluding charging of R- 410A refrigerant Air-flow/per IDU:- 1000CFM ( Make - Hitachi/ Mitsubishi Heavy/ O-General/Daikin) [NS]
Installation, testing, & commisioning of indoor & outdoor unit of above concealed type Split Air Conditioner AC machines after making hole in wall as per direction of EIC. Including S&F of suitable adjustable powder coated painted heavy duty iron brackect with mending the good damaged and laying and making connection of refrigerant pipe after testing the leak by gas pressure (minimum 400PSI) and vacuuming the unit properly (minimum -30 PSI) hold the vacuum up to 48 hrs after release the gas testing the split type room Air conditioner as per direction of EIC. [NS]
Supplying, fabrication & fixing M.S angel iron -channel of 6 mm thick of size (50 mm x 50 mm x6 mm) for making platform for installation of indoor unit of 2.5 TR concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 50 mm x 50 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform.The entire structure should be baricaded with adequate service access as per direction of EIC. [NS]
Supply, fabrication &ereation of fabricated 22SWG Air duct of galvanised steel sheet(make as per direction of EIC) as per IS: 277, CLASS Viii with 120 GSM Zinc coating both side and fabrication stranded shall as per Iis:655 with necessary fittings & all accessories as required as per the rerquirement and designed approved by the EIC. [NS]
Supply and fixing of Al powder coated continuous Grill (Make Premier/Ravister/ Dynacraft) [NS]
Supply & laying Refrigerant Copper pipe minimum Thicknes1.15 mm. Liquid pipe 9.52 mm (3/8") & Gas pipe 15.88mm (5/8") (Make - Royku/Totaline/Mandeep) and insulation of refrigerant copper pipeping by nitril rubber insulation tube of minimum thickness 9mm.(Make - Aroflex/Acoflex) also raping the insulation & copper wire with GKB Gold raping tape as direction of EIC. [NS]
Supply and drawing 4 core 2.5 sq.mm PVC insulated sheeted wire for connecting the outdoor to indoor communicaion supply. (Make - Havels/Finolex)[NS]
Supply & laying drain water piping work out of UPVC /HDPE hard pipes of 25mm dia 4mm thick (Make- HB/Supreme) incl. fitting accessories bends,elbows,tees, flanges,tapings etc. [NS]
S&F Timer Control Unit for single phase AC Machine assembled with - 12-way SPN DB Box (L&T / Cabtree/Legrand/Siemens/ABB) - 1 no. 32 A FP MCB Isolator (Make: Siemense / Legrand / L&T) - 01 no. Digital 24 hour time switch (GIC/L&T) - 1 no. 32A three pole contactor (L&T) - 01 no. Centre off 2 way toggle switch - 1 no. 32Amp. Barirrer type terminal- 1 no. LED indicating lamp (L&T: SIL R 240V) - 01 No. 2X4sqmm+2.5sqmm copper wire 0.5 Mtr. with complete interconnection with auto-mannual bypass arrangement with locking arrangement incl. making/cutting door of SPN DB box for fixing arrangement of toggle switch, Locking arrangement, LED indicator etc. as required as per direction of EIC. [NS]
Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB, incl. 32 A FP MCB Isolator, concealed/surface in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [PWD/GS Page: D-9 Item: 11, D-9 Item: 13 ]
Supplying & Laying of one PVC insulated sheathed Al / XLPE armoured power cable of 1.1 KV grade 4 Core x 25 sq.mm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [Make : Nicco / Gloster/Polycab / RR] [ From DB to AC Outdoor ] [Supply of cable - Non-Schedule Item, Laying of Cable - PWD/GS Page: F-1 Item: 2
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 4 Core x 25 sq.mm . [PWD/GS Page: F-4 Item: 7/c ]
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 4 Core x 25 sq.mm [PWD/GS Page: F-5 Item: 8/b ]
Supply and fixing 415V. 4 way, Double Door MCCB incomer VTPN DB with IP 42/43 protection, having 100 A adjustable Four pole MCCB as incomer 4 nos 63 A TP MCB (10 KA)as outgoings, concealed in wall after cutting the wall and mending good the damages to original finish including interconnection and terminations with suitable size of copper wire, duly socketed by solderless Copper Socket and neutral link and provision for earthing attachment, as per direction of E.I.C.(Make -Legrand/ABB/L&T /Seimens) [PWD/GS Page: D-11 Item: 15, Page: D-8 Item: 10, Page: D-6 Item: 7]
Supplying & Laying of one PVC insulated sheathed Al / XLPE armoured power cable of 1.1 KV grade 4 Core x 35 sq.mm on existing Cable Tray and binding with suitable size GI wire. [Make : Nicco / Gloster/Polycab / RR] [ From Lift fron panel to VTPN ] [Supply of cable - Non-Schedule Item, Laying of Cable - PWD/GS Page: F-3 Item: 6
Supplying & Laying of one PVC insulated sheathed Al / XLPE armoured power cable of 1.1 KV grade 4 Core x 35 sq.mm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [Make : Nicco / Gloster/Polycab / RR] [ From Lift fron panel to VTPN ] [Supply of cable - Non-Schedule Item, Laying of Cable - PWD/GS Page: F-1 Item: 2
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 4 Core x 35 sq.mm . [PWD/GS Page: F-4 Item: 7/c ]
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 4 Core x 35 sq.mm [PWD/GS Page: F-5 Item: 8/b ]
Supply & Fixing 240 V, 1 nos. 6 A, 3 pin Modular type plug socket & 1 nos. 6/16 A, 5 pin Modular type plug socket (Brand approved by EIC) with separate 1 nos. 6A Modular type switch & 1 nos. 6/16 A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [PWD/GS Page: E-17 Item: 1, 3, 4]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25mm or suitable size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [PWD/GS Page: E-14 Item: E/1/a] 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2 x 1.5 sq mm + 1X 2.5 sq.mm [PWD/GS Page: F-5 Item: 9 ]
2 x 2.5 sq mm + 1X 1.5 sqmm [PWD/GS Page: E-9 Item: 1 ] [HTPN DB To Power Plug ]
Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct.
M/s Joy Durga Electric Repairing Shop (BID ID -5784818)
JASODA REFRIGERATOR SERVICING CENTRE (BID ID -5792302)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .