| 1 | L1₹5.0 LAdmitted-Finance 1 6 FAKIR CHAKRABORTY LANE | ₹5.0 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 L+₹1,780.07 (0.36%)Admitted-Finance 4 ASWINI DUTTA LANE CINEMA HOUSE LANE KRISHNAGAR NADIA PIN 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹5.0 L+₹1,780.07 (0.36%) | L2 | Admitted-Finance |
| 3 | L3₹5.0 L+₹2,968.77 (0.60%)Admitted-Finance ADAM KANAN JHARGRAM 721507 | JHARGRAM | WEST BENGAL | 721507 | ₹5.0 L+₹2,968.77 (0.60%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DEBJYOTI BASU L3 | HARA PROSAD DAS L2 | H.K.DAS & CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing damaged main switch , Changeover , cable etc. & allied from existing position all complete & kept at site. | 1 | item | 1,007 ₹1,007 | 1,001 ₹1,001 | 995 ₹995 Lowest |
| 2.00 | Supply & delivery at site of 25 Sq. mm. 1.1 KV grade 3½ core Al. conductor armoured P.V.C. /XLPE insulated cable. NB: Cable to be supplied as per sire requirement.
( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab/any other approved make) | 40 | mtrs. | 510 ₹20,400 | 507 ₹20,280 | 505 ₹20,200 Lowest |
| 3.00Supply, Delivery and Storage at Site of 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor wall Mounted 415 Volt MCC Panel( 12.5 HP) having following specification:-Incommer : i) FP MCCB with O/L , S/C Protection(63Amps,25KA)- 01 no. ii) Digital Ammeter -------------- 01 no. iii) Ammeter Selector Switch---------------- 01 no iv) C.T for Ammeter (60 : 5)-------------- 03 nos. v) Digital Voltmeter---------------- 01 no. | ||||||
| 3.10vi) Voltmeter Selector Switch,--------01 no. vii) SP MCB for voltmeter (6 Amp) ------- 03 nos. viii)Phase Indicating Lamp ------- 03 nos. ix Voltage monitoring relay.....01No. x) Voltage trip Indicator.........01No xi) Surge protection Device----01No. xii)TPN MCB (25A ,10Ka)....01No. xiii) Auto Phase Reversal Correction Device---- 01 no. Xiv) Logic Contactor(4A) ----01 no. | ||||||
| 3.11Outgoing: i) MPCB (16 -20 Amps)------------- 02 no. ii) Motor Protection Relay(0.5-80)A..........02 no. iii) Contractor (32 Amp)-------------------- 04 no. iv) Contractor (25 Amp)-------------------- 02 no. v)Capacitor (4 KVAR)--------------------- 02 no. vi)Contactor for capacitor(12 Amps)----------- 02 no. vii)TP MCB for capacitor (16 Amps) --------------- 02no. | ||||||
| 3.12viii)Star-Delta Timer (3-120 Sec) ----------- 02 no. ix)On-Delay timer ....02Nos x) DP MCB (6 Amp) --------- 02 no. xi)ON/OFF/Trip Indicator -------- 06 nos xii) Start/Stop Push Button--------- 04nos. | ||||||
| 3.13 | For Chlorinator: i) TP MCB (16 Amp) -----01no. ii) Over Load Relay (1.0 - 1.4 Amp) ----01 no. iii) Contactor(9Amp) ------01 no. iv) Water Level Controller ------- 01 no. v) ON/OFF/Trip Indicator ------ 03 nos. vi)Start/Stop Push Buttom------- 02 nos. | 1 | Set | 2,67,994 ₹2,67,994 | 2,67,855 ₹2,67,855 | 2,67,651 ₹2,67,651 Lowest |
| 4.00 | Installation of the above Panel on as in item no. 3 wall with complete cable connection as per direction supplying all required materials and commissioning the same as per satisfaction of E.I.C | 1 | Item | 4,545 ₹4,545 | 4,515 ₹4,515 | 4,497 ₹4,497 Lowest |
| 5.00 | Supply & delivery at site of 100 Amp TPN Rewire able type switch fuse.
( Make Havells/ GEC/ Standard/any other approved make) | 2 | Nos. | 12,587 ₹25,174 | 12,545 ₹25,090 | 12,485 ₹24,970 Lowest |
| 6.00 | Supply & delivery at site of 100Amps wall mounted 4-way Bus-Bar chamber having 4nos. Copper bus-bar.
( Make Havells/ L&T/ Standard/any other approved make) | 1 | No. | 13,660 ₹13,660 | 13,465 ₹13,465 | 13,406 ₹13,406 Lowest |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
17 Aug 2026, 5:00 pmClosed
Executive Engineer Eastern Mechanical Division P.
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG KOL 73
Renovation of power distribution arrangement with allied works at P.H.No- High Lift of KOLA Ground water-based W/S Scheme under EMD, PHE Dte.in 24Pgs(N).
2026_PHED_1033283_20
WBPHED/EE/EMD/NIET-04/2026-27
Open Tender
Miscellaneous Works
Item Wise
30 days
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,000
8 Sept 2026
30 Jul 2026
20 Aug 2026
30 Jul 2026
17 Aug 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the existing damaged main switch , Changeover , cable etc. & allied from existing position all complete & kept at site. | 1 | item | - | - |
| 2 | Supply & delivery at site of 25 Sq. mm. 1.1 KV grade 3½ core Al. conductor armoured P.V.C. /XLPE insulated cable. NB: Cable to be supplied as per sire requirement.
( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab/any other approved make) | 40 | mtrs. | - | - |
| 3Supply, Delivery and Storage at Site of 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor wall Mounted 415 Volt MCC Panel( 12.5 HP) having following specification:-Incommer : i) FP MCCB with O/L , S/C Protection(63Amps,25KA)- 01 no. ii) Digital Ammeter -------------- 01 no. iii) Ammeter Selector Switch---------------- 01 no iv) C.T for Ammeter (60 : 5)-------------- 03 nos. v) Digital Voltmeter---------------- 01 no. | |||||
| 3.1 | vi) Voltmeter Selector Switch,--------01 no. vii) SP MCB for voltmeter (6 Amp) ------- 03 nos. viii)Phase Indicating Lamp ------- 03 nos.
ix Voltage monitoring relay.....01No.
x) Voltage trip Indicator.........01No
xi) Surge protection Device----01No.
xii)TPN MCB (25A ,10Ka)....01No. xiii) Auto Phase Reversal Correction Device---- 01 no.
Xiv) Logic Contactor(4A) ----01 no. | - | - | - | - |
| 3.11 | Outgoing: i) MPCB (16 -20 Amps)------------- 02 no. ii) Motor Protection Relay(0.5-80)A..........02 no. iii) Contractor (32 Amp)-------------------- 04 no.
iv) Contractor (25 Amp)-------------------- 02 no. v)Capacitor (4 KVAR)--------------------- 02 no. vi)Contactor for capacitor(12 Amps)----------- 02 no. vii)TP MCB for capacitor (16 Amps) --------------- 02no. | - | - | - | - |
| 3.12 | viii)Star-Delta Timer (3-120 Sec) ----------- 02 no.
ix)On-Delay timer ....02Nos x) DP MCB (6 Amp) --------- 02 no. xi)ON/OFF/Trip Indicator -------- 06 nos xii) Start/Stop Push Button--------- 04nos. | - | - | - | - |
| 3.13 | For Chlorinator: i) TP MCB (16 Amp) -----01no. ii) Over Load Relay (1.0 - 1.4 Amp) ----01 no. iii) Contactor(9Amp) ------01 no. iv) Water Level Controller ------- 01 no. v) ON/OFF/Trip Indicator ------ 03 nos. vi)Start/Stop Push Buttom------- 02 nos. | 1 | Set | - | - |
| 4 | Installation of the above Panel on as in item no. 3 wall with complete cable connection as per direction supplying all required materials and commissioning the same as per satisfaction of E.I.C | 1 | Item | - | - |
| 5 | Supply & delivery at site of 100 Amp TPN Rewire able type switch fuse.
( Make Havells/ GEC/ Standard/any other approved make) | 2 | Nos. | - | - |
| 6 | Supply & delivery at site of 100Amps wall mounted 4-way Bus-Bar chamber having 4nos. Copper bus-bar.
( Make Havells/ L&T/ Standard/any other approved make) | 1 | No. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
Tendernotice_2.pdf
PDF • 0.58 MB
BOQ_2542676.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .