| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹21.5 L+₹1.3 L (6.24%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹24.1 L+₹3.9 L (19.1%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹24.3 L+₹4.1 L (20.1%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest | |
| 5 | L5₹25.2 L+₹5.0 L (24.7%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L5 | Rejected-Finance Being not a lowest |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
10 Mar 2020, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
SPECIAL REPAIR TO LT PANELS, CHANGE OVER SWITCHES AND STREET LIGHTS INCLUDING CERTAIN LBW, REVENUE WORKS AND MINOR WORKS UNDER AGE EM OF GE (WEST) PATHANKOT
2020_MES_324295_1
GE/PKT-71/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹75,000
Yes
25 Mar 2020
12 Feb 2020
12 Mar 2020
12 Feb 2020
10 Mar 2020
26 Feb 2020
14 Feb 2020 - 20 Feb 2020
Amount
Taking down existing street light fitting complete and hand over to the MES store yard complete all as specied and directed.
S&F LED light fitting 90 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated copper conductor (multistranded) cable of 1.5 Sq mm size in PVC conduit with clamps complete all as specified and directed by Engr-in-Charge (Note:- New bracket and PVC conduit & wire will be paid and measured separetly under respective item of schedule)
S&F LED light fitting 60 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated copper conductor (multistranded)FR cable of 1.5 Sq mm size in PVC conduit with clamps complete all as specified and directed by Engr-in-Charge (Note:- New bracket and PVC conduit & wire will be paid and measured separetly under respective item of schedule)
S&F LED light fitting 45 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated copper conductor (multistranded)FR cable of 1.5 Sq mm size in PVC conduit with clamps complete all as specified and directed by Engr-in-Charge (Note:- New bracket and PVC conduit & wire will be paid and measured separetly under respective item of schedule)
S&F LED flood light fitting 120 W, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features on existing high mast poles/wall/any position or place on existing/New place and making connections with provision of PVC insulated copper conductor (multistranded) cable of 1.5 Sq mm size, complete all as specified and directed by Engr-in-Charge.
M&L for of bracket in replacement for fixing of street light fittings bend to shape, made out of 32 mm dia GI pipe medium grade 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over and including a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M&L for factory made sheet metal enclosure of suitable size out door type fabricated out of 2.4 mm thick CRCA sheet powder coated dust and vermin proof having entry from lower side with cable gland for cable of size 25/16/10 Sq mm 2/4 core (as per site requirement) with aluminium bus bar single phase and nautral current carrying capacity of aluminium bus bar should be upto 63 Amps mounted on poreclain insulator complete with operating voltage 220 volts, 50 Hz including one number MCB of capacity 6 amp for street light mounted in sheet enclosure prewired with minimum 1.5 Sq mm copper conductor cable with lugs including locking arrangement complete and enclosure fitting on pole with clamps nuts, bolts and washers including making connection from Junction box to S/L fitting with 1.5 sqmm PVC insulated FRLS cable for phase, neutral and earth complete or all as specified and directed by Engr-in-Charge.
S&F three core copper conductor PVC insulated cable of size 1.5 sqmm FRLS multistranded 1100 volts grade complete all as specified and directed by Engr-in-charge.
S&F three core PVC insulated and FRLS PVC round sheathed, aluminium conductor 1100 volts grade cable of size 6 sqmm (multistranded) complete all as specified and directed by Engr-in-charge.
S&F PVC pipe heavy duty 15 mm dia fixed to pole complete all as directed by Engr-in-charge.
M&L for Prestressed concrete pole, 9.0 metres long 102mm x 152mm at top and 102 mm x 289 mm at bottom, class 10, and applying two coats of synethic enamel paint upto 1.5 mtr from top of coping in black and white strip alternately each 30 cm wide including writing MES No. on Pole with synthetic enamel paint complete all as directed by Engr-in-charge. (Note:- Earth work including excavation, Returning filing, PCC work, removing excavated material will be measured and paid separetly under respective items of schedule) Make:- Cement fabric chandigarh/Concrete Ltd chandigarh/Haryana concrete udyog Ltd/ PCIC/ECI/ ICB industries/Hindustan prefab/ KB industries.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
All as per srl item No. 12.00 here-in-before but depth exceeding 1.5 mtr and not exceeding 3 mtr complete all as specified and directed.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable punned down upto 18cm complete all as specified and directed. (Note: Punned thickness 18cm shall be considered for payment purpose.)
M&L for Brick covering, bricks laid flat perpendicular to the length of cable as mechanical protection to cable with well burnt sub class 'B' bricks complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply, laying and testing in replacement of XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Supply, laying and testing in replacement of XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, laying and testing in replacement of XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing in replacement of XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
M&L for Automatic street light timer switch Single phase 3kW (25 amps) with RMC Enclosure confirming to IP 54 complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 ( Using 40mm graded stone aggregate) as in foundation of poles filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 ( using20mm graded stone aggregate) as in foundation of poles/coping,stay etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 4.0 mm dia GI wire by means of bolts, nuts, check buts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1;2:4) type B-1 using 20 mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25mmx25mmx6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 75mmx50mmx6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling and removal of surplus soil to a distance not exceeding 50 mtr all per plate No 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Earthing complet with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and earth lead protected by provision of GI light grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1;2:4) reinfored with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning filling in distance not exceeding 50 mtr and removal of surplus soil complete all as per plate No 3 of SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on completion.
Supply ,Installation ,testing & commisioning of totally enclosed feeder piller outdoor type (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type(independent cabin including locking arrangement complete suitable for operating on 415 Volt 50 Hz AC, supply internally wired with copper conductor , TPN bus bar of copper strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault level at 415 Volts,sliding bolts should be fitted for pad locking arrangements and godrej nav tal pad lock with 3 keys to be provided as specified and directed by engineer incharge,having legs 105cms made out of 65x65x6 mm angle iron grouted in PCC block of size 20cm x 20cm x 45cm pannel should be 60 cms above the Ground Level comprising the following :-
(i) The panel shall be front operated with independent side cable cabin for entry and out going from the bottom with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms. (Note:- Cost of grounting of panel with PCC 1:3:6 (40 mm thick stone aggerate) deemed to be included in the item rate . No extra payment will be made. (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 50 KA. Earth bus shall be part of the main feeder pillar.
Supply and install HT 11KV Out door gang operated device air break switch suitable for horizontal or vertical mounting switch with dropout fuse having 12 insulators of rating capacity 200 amps complete by dismantlimg old burnt, complete all as specified and directed.
S&F single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed.
S&F test point terminal block made of gun metal of phophorys bronze size 75x75x25mm drilled and screwed including 3 nos, 8 mm dia, 25 mm long hexagonal head screw complete all as specified and directed.
S&F aluminium strip 25mm x 3mm with saddles and fixing screws for fitting the strip complete all as specified and directed.
S&F GI strip 32mm x 6mm buried in ground complete all as specified and directed.
Supply and fixing GI tubing light grade of 40 mm dia with all fittings and fixed to wall and ceilings or fixed to top of roof for fixing af air termination complete all as specified and directed.
Supply and fixing cross arm bracing supports clamps and back plate fabricated from structural steel section including nuts, bolts, washer, welding, bending hot or cold drilling holes for bolts in any shape or size including two coats of aluminioum paint over and including a coat of red oxide primer complete all as specified and directed.
S&F Refrigerator, electric driven (Single phase), having storage capacity of 310 Ltrs BEE 5 star rating complete all as specified and directed.
S&F Deep freezer metal top (single phase), 240 volts 50 HZ capacity 200 Ltr, 5 star rated complete all as specified and directed.
S&F water cooler fully stainless steel, electric driven (Single phase), 5 star rated, having storage capacity of 150 Ltrs and nominal cooling capacity of 150 Ltrs per hour complete all as specified and directed.
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 90V to 280V with output voltage stabilized at 230V with accuracy of + 2.5% but of capacity 1 KVA complete all as specified and directed.
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 90V to 280V with output voltage stabilized at 230V with accuracy of + 2.5% but of capacity 3 KVA complete all as specified and directed.
M&L for point wiring with 2.5sqmm PVC insulated unsheathed FRLS multistranded copper conductor and including PVC concealed conduit heavu duty having thickness not less than 1.8mm with all fitting including anodised pressed steel sunken box having thickness not less than 2mm with 3mm thick bakalite laminated sheet of suitable size for 5 pin15 amps socket outlet , including 2.5 sqmm PVC insulated unsheathed FRLS multistandrad copper conductor as earth continitity conductor connected to common earth dolly and including cutting chiseling for concealed piping and making good disturbed surface area and finishing the surface to match with existing colour complete all as specified and directed.
S&F PVC connection for hot & cold water 15mm dia and 450mm long with PTMT nuts complete all as specified and directed.
Supply, laying & testing galvanized iron pipe 15mm (1/2") dia Medium Grade including fittings fixed to wall, laid in floor or ceiling complete all as specified and directed.
S&F stop valves, cast copper alloy, screwed down, high pressure with crutcher butterfly handle, screwed both ends for 15mm bore dia of pipe complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 20Amp single pole MCB 'C' curve 10 KA complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 pin 5/15 amp flush type, 240 volts complete all as specified and directed.
S&F Storage type Electric water heater (Geyser) PVC Body capacity 25 litres BEE 5 Star rating with PVC connection 15mm dia 450mm long with brass nuts complete all as specified and directed.
S&F Storage type Electric water heater (Geyser) PVC Body capacity 50 litres BEE 5 Star rating with PVC connection 15mm dia 450mm long with brass nuts complete all as specified and directed.
S& F Bib taps cost copper alloy, with crutch of butter fly handle, screwed down, high pressure, screwed for 15mm dia pipe complete all as specified and directed.
M & L for point wiring with 1.50 sqmm, FRLS PVC insulated and unsheathed flexible copper conductor cable (multistrand) in rigid PVC concealed conduit having thickness not less than 1.8 mm with all fittings and terminated in PVC sunken box with suitable plastic laminated sheet cover 3mm thick of adequate size and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan point all as specified and directed by Engr-in-Charge. Note:- (a) Rate for cutting chases for conduits and sinking for boxes and making good to disturbed wall floor is deemed to be included in quoted rate. (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary points with proper fixing clips and no extra cost shall be paid for the job.
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S & F ceiling rose surface bakelite, isolated body, three terminals fixed on PVC round block complete all as specified and directed.
M & L for providing/ cutting the round/ square hole of required size in wall making good the distrubed surfaces and finishing as per existing complete all as spd and supply and fixing exhaust fan 380 mm sweep, 230 volts complete and supply and grouting the ragged bolts in wall, fixing the frame and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
M & L for providing/ cutting the round/ square hole of required size in wall making good the distrubed surfaces and finishing as per existing complete all as spd and supply and fixing exhaust fan 230 mm sweep, 230 volts complete and supply and grouting the ragged bolts in wall, fixing the frame and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
S & F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB Four pole 100 amps AC 415 VOLTS 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series (Note :- (i)The DB shall be VTPN series. (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi) MCB's should have a same make as of DB.
S & F in replacement MCB SPN 240 volts, 'C' curve of rating 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 18,692.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder within 28 days from the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
M/S SHAKTI ELECTRIC WORKS
satpal and brothers
JAI DURGA CONSTRUCTION CO
SATISH AND CO
KULBHUSHAN AGGARWAL
RD Engineers
M/s USHA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .