Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.9 L+₹4,392 (0.20%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.4 L+₹2.6 L (11.7%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹24.9 L+₹3.1 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹28.0 L+₹6.1 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Jul 2021, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR/ REPLACEMENT AND MAINTENANCE OF INTERNAL ELECTRIFICATION OF LIFT MACHINE ROOM, LIFT SHAFT AND MISC OTHER ITEMS AT VARIOUS LOCATION UNDER GE(U) PM DELHI CANTT-10
2021_MES_450165_1
GE(U)/PM/D-09/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DELHI CANTT
MES contractor enlisted under class D category b(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹90,000
Yes
16 Jul 2021
10 Jun 2021
10 Jul 2021
10 Jun 2021
8 Jul 2021
24 Jun 2021
Amount
Taking down carefully existing surface/ concealed unserviceable aluminum/ copper point wiring (light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, bracket holder, boards light fittings, etc. and making good to disturbed surfaces of walls, floors, ceilings, etc. where required and finished the existing surfaces after complete of new point wiring as specified here-in-after complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable DB of any type/ size (including MCB any type/ capacity) carefully disconnecting and making good disturbed surface complete all as specified and directed by Engr-in-Charge.
M & L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through in existing concealed / surface PVC/Steel conduit and accessories and existging MS pressed steel terminal box and replace laminated sheet 3mm thick for mounting of switches, socket regulator etc including 1.5 Sqmm PVC insulated FRLS unsheathed cable multistranded copper conductor and connecting to earth dolly for for one light / Fan / exhaust fan / Bell point controlled by one, one way switch complete all as specified & directed by Engr-in-Charge. (Make of cable:- FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB .) {Notes:- (i) Switches and sockets to be measured and paid for separately under relevent items.}
-ditto- all as per item No. 4 above but for one 3 pin 5/6 Ampere socket outlet point controlled by one, one way switch on the independent board complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No. 4 above but for one 3 pin 5/6 Ampere socket outlet point controlled by one, one way switch on the same board complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No. 4.00 above but with 4 Sqmm cable for 15 Amp switch socket out let point on independent board including 4 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all as directed and specified by Engr-in-charge. Notes:- (i) Switches and sockets to be measured and paid for separately under relevent items.
Supply and fixing of switch piano, flush button type, ivory finish 5/6 Ampere single pole, one way complete, all as specified and directed by Engr-in-Charge. (Make : Anchor / Legrand/ Schneider/ C & S/ Cona / Havells)
Supply and fixing of socket out let combination, 5 pin 5/6 Ampere 230V AC flush type complete all as specified and directed by Engr-in-Charge. (Make : Anchor / Legrand/ Schneider/ C & S/ Cona / Havells)
Supply and fixing of socket out let 2 in 1, 3 Pin suitable for 5/6 Ampere and 3 Pin suitable 15/16 Ampere flush type complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Legrand/ Schneider/ C & S/ Cona / Havells)
Supply and fixing of ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminal complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Ess Ess Kay / Havells / Cona)
Supply and fixing of lamp holder pendant/angle type, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed by Engr-in-Charge. (Make : Anchor / Ess Ess Kay / Plaza / Havells)
Supply & fixing of LED tube light fitting 18/20 watts with tube rod and necessary braket, clamps, including bolts, nuts & washers for fixing arrangement etc including taking down old unserviceable one complete all as specifed and directed by Engineer-in-charge. (Make-Havells Cat No LUMILINEPLUSBS18WLED865SPCSS or equivalent cat/ model of make PHILIPS/ BAJAJ/ CROMPTON GREAVES/ C & S ELECTRIC/ OSRAM)
Supply & fixing of LED light fitting 10 watts with LED tube rod, ready to use pack with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc including taking down old unserviceable one complete all as specifed and directed by Engineer-in-charge. (Make-Havells Cat No LUMILINEPLUSBS10WLED865SPCSS or equivalent cat/ model of make PHILIPS/ BAJAJ/ CROMPTON GREAVES/ C & S ELECTRIC/ OSRAM)
Supply & fixing of surface mounting Bulkhead LED fitting13.5 watts luminarie complete fitting with all fixing arrangement including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make-Havells Cat No LHEXCGP7IN5W013 or equivalent cat/ model of make PHILIPS/ BAJAJ/ CROMPTON GREAVES/ C & S ELECTRIC/ OSRAM)
Material and labour for sub main wiring with two runs of single core 1.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 20mm dia or more dia with all fittings and accessories surface type including one run 1.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed by Engr-in-Charge.
Material and labour for sub main wiring with two runs of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 20mm dia or more dia with all fittings and accessories surface type including one run 2.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed by Engr-in-Charge.
Material and labour for sub main wiring with two runs of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC Conduit (heavy grade) of 20mm dia or more dia with all fittings and accessories surface type including one run 4.0 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed by Engr-in-Charge. Notes for item Nos 16.00 to 18.00 (Make of cable : FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB/ L & T/ ANCHOR.) (Make of PVC conduit:- FINOLEX / PLAZA/ KALINGA/ SUPREME/ BAJAJ/ PRINCE.) Note : (a) Two runs cable and one run earth wire measured as one unit. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Suitable colour code of wire shall be maintained for phase / neutral / earth). (d) Earth wire shall run inside the conduit.
Supply & fixing of MCCB DB VTPN 4 ways,with metal double door, IP -54 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to cat part no-5077 50 of legrand complete including MCCB 250A, cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site complete all as specified and directed by Engr-in charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing of MCB SPN 4 way, double door, 230 Volts SPN Metalic Distributition board, concealed flush to wall for mounting MCBs factory made , conforming to IS : 13032 fabricated out of CRCA sheet fitted with DIN channel, neutral link and approriate rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature , between powder paint process to ensure smooth finish and protection against corrsion atmosphere. the DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, the DBs shall be of IP 43 IK-09 protection class complete all as specified and directed by Engr-in-Charge. (Make : L & T/ ABB/ Legrand/ Schneider/ Seimens / Merlin Gerin)
Supply and fixing of MCB SPN 8 way, double door, 230 Volts SPN Metalic Distributition board, concealed flush to wall for mounting MCBs factory made , conforming to IS : 13032 fabricated out of CRCA sheet fitted with DIN channel, neutral link and approriate rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature , between powder paint process to ensure smooth finish and protection against corrsion atmosphere. the DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, the DBs shall be of IP 43 IK-09 protection class complete all as specified and directed by Engr-in-Charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing of MCB SPN 12 way, double door, 230 Volts SPN Metalic Distributition board, concealed flush to wall for mounting MCBs factory made , conforming to IS : 13032 fabricated out of CRCA sheet fitted with DIN channel, neutral link and approriate rated bus bar DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature , between powder paint process to ensure smooth finish and protection against corrsion atmosphere. the DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways as specified, the DBs shall be of IP 43 IK-09 protection class complete all as specified and directed by Engr-in-Charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing miniature circuit breaker (MCB) single pole with thermal overload for inductive load as well as magnetic short circuit tripping device with quick break trip free mechanism robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts 06 to 32 Ampere current rating 'B' curve 10 kA breaking capacity complete all as specified and directed by Engr-in-Charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing miniature circuit breaker (MCB) double pole with thermal overload for inductive load as well as magnetic short circuit tripping device with quick break trip free mechanism robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts 06 to 32 Ampere current rating 'B' curve 10 kA breaking capacity complete all as specified and directed by Engr-in-Charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing miniature circuit breaker (MCB) Triple pole with thermal overload for inductive load as well as magnetic short circuit tripping device with quick break trip free mechanism robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 volts 06 to 32 Ampere current rating 'B' curve 10 kA breaking capacity complete all as specified and directed by Engr-in-Charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Re-Fixing only MCB SP /SPN/TP/MCCB as obtained from item No-03 above including connected with suitable size of copper lugs complete all as directed .
Supply and fixing in repairs of sheet metal enclosure single pole and neutral with two pin earth plug and socket complete with one single pole MCB 20 Amp 240 volts half grouting on wall all as specified and directed by Engr-in-Charge. (Make:- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Taking down of ceiling fan / exhaust fan of any size/sweep for overhauling/ servicing comprising dismantaling , cleaning internally and externally including applying one coat of paint and cleaning/lubricating of bearing/buses using fresh lubricant (Oil grease) re-assembling, hanging on same position, connecting and testing for proper functioning complete all as specified and as directed by Engr-in-Charge. Notes: (i) Replacement of defective spares for making the ceiling fan units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only'. (ii) Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (iii) Required defective split pin, roller rubber and suitable connecting wire of same size and core shall deemed to be included in unit quoted rate.
Taking down the existing unserviceable exhaust fan and Supply and fixing of exhaust fan of 300mm sweep, 1400 RPM heavy duty metalic body with louver shutter, 230 volts AC supply including necessary nuts, bolts connecting with PVC insulated sheathed cable of sutable size and length from ceiling rose complete including taking down old unserviceable one complete all as specified and as directed by Engr-in-Charge. (Make :- Havells/ Khaitan/ Orient/ Bajaj / GEC/ Crompton Greaves.)
Taking down the existing unserviceable exhaust fan and Supply and fixing of exhaust fan of 380mm sweep, 1400 RPM heavy duty metalic body with louver shutter, 230 volts AC supply including necessary nuts, bolts connecting with PVC insulated sheathed cable of sutable size and length from ceiling rose complete including taking down old unserviceable one complete all as specified and as directed by Engr-in-Charge. (Make :- Havells/ Khaitan/ Orient/ Bajaj / GEC/ Crompton Greaves.)
Supply and fixing of Automatic Phase sequence corrector 15 HP motor protection with due proof,vermin proof duly powder coated enclosure. Protection IP-54 with no breakdown of lifts, 3 phase system due to change in phase sequence. Complete with phase sequence relay,Contactor,timer,MCB,indication light, connector terminal etc including necessary wiring and connected accessories including taking down old unserviceable one complete all as directed by Engr-In-charge. (Make: - Marco Transformer /Universell switch gear/KSS electricals)
Supply and fixing of Automatic Phase sequence corrector 30 HP motor protection with due proof,vermin proof duly powder coated enclosure. Protection IP-54 with no breakdown of lifts, 3 phase system due to change in phase sequence. Complete with phase sequence relay,Contactor,timer,MCB,indication light, connector terminal etc including necessary wiring and connected accessories including taking down old unserviceable one complete all as directed by Engr-In-charge. (Make:- L&T/ Siemens/Legrand/ ABB/ Schneider/ C & S Electric/ Sinetrac.)
Taking down defective change over switch and Supply & fixing of enclosed changeover switch of capacity 100amps 415 volts 3 phase including all fixinging arrangement., complete all as specified and directed by Engr-in- charge. (Make : L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip of 32 x 6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. (Make of GI Pipe:-JINDAL/ TATA/ BST/ PRAKASH TUBES/ OSWAL) (Note:- Each protection pipe and earthing lead upto and including 7.5 meter lenght is deemed to be included in the qouted rate of this item.)
M & L of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc using 32x6mm galvanised iron strip including taking down old unserviceable one complete all as specified & directed by Engr-in-Charge.
M/s Adhikari construction co.
P S TRADERS
Surjit and Sons
Garg Engineers
Ridhi engineers and builders
Iconic Engineers
BUSINESS TEK INDIA
M/s Dhapola Elevator and Engineering
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .