Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.9 LAccepted-AOC | ₹74.9 L Quoted ₹77.7 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹84.3 L+₹6.6 L (8.47%)Rejected-Finance | ₹84.3 L+₹6.6 L (8.47%) | L2 | Rejected-Finance Quoted rate higher than L1 Bidder |
| 3 | L3₹85.4 L+₹7.7 L (9.96%)Rejected-Finance | ₹85.4 L+₹7.7 L (9.96%) | L3 | Rejected-Finance Quoted rate higher than L1 Bidder |
| 4 | L4₹86.1 L+₹8.4 L (10.8%)Rejected-Finance | ₹86.1 L+₹8.4 L (10.8%) | L4 | Rejected-Finance Quoted rate higher than L1 Bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical NIT Criteria not fulfilled |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
4 Aug 2020, 3:00 pmClosed
CWE
HQ 137 WE PIN 914137 C O 99 APO
PROVN OF PVC WATER TANK IN JCOs OR MD ACCN AT LEIMAKHONG MIL STN
2020_MES_358682_1
8458/E8
Open Tender
Civil Works
Item Rate
270 days
LEIMAKHONG
Class B Category a i
2 documents required · 2 mandatory
₹1,000
GE 869 EWS
₹1.8 L
Yes
26 Nov 2020
6 Jul 2020
6 Aug 2020
6 Jul 2020
4 Aug 2020
20 Jul 2020
Amount
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition and removing debries from site of work complete all as directed.
Material and labour for 25mm thick, PCC (1:2:4) type B0, (using 12.50 mm graded stone aggregate) as in roof padding etc and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for removal of existing roof treatment and repair the surfaces with 10 mm thick screed bed on concrete surface in cement mortar (1:3) and finished the surfaces fair and even complete all as specified and as directed.
Material and labour for water proofing treatment to RCC roof slab incl parapet comprising with the following course of treatment/specifications from bottom to top :- (a) Applying bituminous primer @ 100 gm/sqm over plastered surfaces of roof incl parapet surfaces. (b) One layer of APP based polymeric membrane of approved manufacturer,3mm thick, weight not less than 3.50 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gm/sqm). Polymeric membrane shall taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note: (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions. (c) Applying one coats of bituminous aluminum paint on top of APP membrane @ 0.11Kg/Sqm.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing and deposited to stores complete all as specified and directed.
Taking up or down steel tubing 20mm bore and connections including cleaning for refixing and deposited to stores complete all as specified and directed.
Supply and fixing 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd.
Fixing only 15mm bore galvanised steel water tubing including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. (Note: Serviceable materials as obtained from serial item No. 5.00 on shall be reused under this item)
Supply and fixing 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd.
Fixing only 20mm bore galvanised steel water tubing including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd. (Note: Serviceable materials as obtained from serial item No. 6.00 on shall be reused under this item)
Supply, hoisting and fixing in proper position ISI marked double layer rotational moulded PVC water storage tank (cylindrical vertical with closed top), of capacity 1000 litres including providing necessary connections complete all as specified and as directed.
Supply, hoisting and fixing in proper position ISI marked double layer rotational moulded PVC water storage tank (cylindrical vertical with closed top), of capacity 500 litres including providing necessary connections complete all as specified and as directed.
Supply and fixing as in repair 20mm bore brass float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and fixing as in repair 20mm bore Gun metal gate valve with iron wheel head and gun metal spindle screwed both ends complete all as specified and as directed.
.Supply and fixing as in repair 20mm bore Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and as directed. (Minimum weight 20mm-92gms)
M/S N JADUMANI SINGH
M/S Satish Chand Agarwal
M/S HEIYAM KAN SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .