Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC VPO PANJAUR TEHSIL GARHSHANKAR DISTT HOSHIARPUR PUNJAB | PANJAUR | HOSHIARPUR | PUNJAB | ₹1.8 Cr | L1 | Accepted-AOC ACCEPTED LOWEST BIDDER |
| 2 | L2₹1.8 Cr+₹8.4 L (4.80%)Rejected-Finance HOSHIARPUR | ₹1.8 Cr+₹8.4 L (4.80%) | L2 | Rejected-Finance REJECT |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
31 Aug 2023, 10:00 amClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER KANDI AREA DAM MTC DIVN NO.2 HSP
Estimate for Restoration of damaged/chocked pipeline along with allied work of distribution system of Dholbaha Dam in district Hoshiarpur.
2023_WR_107537_1
38
Open Tender
Civil Works
Item Rate
170 days
VILLAGE DHOLWAHA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
₹3.4 L
Yes
13 Oct 2023
16 Aug 2023
31 Aug 2023
16 Aug 2023
31 Aug 2023
16 Aug 2023
Amount
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect as per design, drawing and instructions of Engineer-in-charge.
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work as per design, drawing and instructions of Engineer-in-charge.
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (90mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (110 mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985@ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125 mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140 mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (200 mm)
Providing, Laying, fixing & jointing of uP.V.C. socketed type Pipe of superior make as per IS 4985 @ 2.5 kgf/sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (200 mm)
Supplying and Fixing upvc Riser for Release of Water at different outlet. Complete in all respect as per Design and P.W.D Specifications and Instruction of Engineer-in-charge. size 110 mm
Supplying and Fixing upvc Riser for Release of Water at different outlet. Complete in all respect as per Design and P.W.D Specifications and Instruction of Engineer-in-charge.(size 125 mm)
Supplying and Fixing upvc Riser for Release of Water at different outlet. Complete in all respect as per Design and P.W.D Specifications and Instruction of Engineer-in-charge. (size 140 mm)
Supplying and Fixing upvc Riser for Release of Water at different outlet. Complete in all respect as per Design and P.W.D Specifications and Instruction of Engineer-in-charge. (size 160 mm)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (90 mm)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (110 mm)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125 mm)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140 mm)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge) B. Class PN-1.6 as per IS complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(90 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(110 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160 mm )
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(200 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(400 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(450 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (500 mm)
Providing & fixing Single Air Valves ISI Mark das per IS-14845 including jointing, cost of nut bolts & rubber insertion all carriages complete. (d)C.I Single air valve screwed (size 50mm) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(550 mm)
Providing & fixing ISI Marked Alfa Valves complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(90 mm )
Providing & fixing ISI Marked Alfa Valves complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(110 mm)
Providing & fixing ISI Marked Alfa Valves complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125 mm)
Providing & fixing ISI Marked Alfa Valves complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140 mm)
Providing & fixing ISI Marked Alfa Valves complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160 mm)
Cement concrete 1:4:8 with stone ballast 40mm gauge, mixing by manual means mixing by mechanical (ii) means using concrete mixer volumetric type complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Cement concrete 1:2:4 With stone ballast or shingle, mixing by mechanical means using concrete mixer volumetric type complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Cement plaster 1:4 12.50mm thick complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Dismantling Brick work tile, masonry or tile lining, (In cement) complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Dismantling Concrete, (b) Cement Concrete plain 1:4:8 complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Dismantling Concrete, (d) Cement Concrete plain 1:2:4 complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) complete in all respect as per design, specifications and instructions of Engineer-in-charge.
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (90mm)
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (110mm)
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (125mm)
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140mm)
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (160mm)
Providing, Laying, fixing & jointing of uP.V.C. sockets as per IS 10124-2009 @ 4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (200mm)
Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(90mm)
Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(110mm)
Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (125mm)
Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISImarked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140mm)
Providing, Laying, fixing & jointing of uP.V.C. 90 deg. bends as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160mm)
Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge..(90mm)
Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(110mm)
Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125mm)
Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140mm)
Providing, Laying, fixing & jointing of uP.V.C. equal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160mm)
Providing, Laying, fixing & jointing of uP.V.C. unequal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (160*160*110mm)
Providing, Laying, fixing & jointing of uP.V.C. unequal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (140*140*125mm)
Providing, Laying, fixing & jointing of uP.V.C. unequal tees as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge. (110*110*90mm)
Providing, Laying, fixing & jointing of uP.V.C. reducer as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.. (90*110mm)
Providing, Laying, fixing & jointing of uP.V.C. reducer as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.. (110*125mm)
Providing, Laying, fixing & jointing of uP.V.C. reducer as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.. (125*140mm)
Providing, Laying, fixing & jointing of uP.V.C. reducer as per IS 10124-2009 @4.0 Kgf. /sqcm (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140*160mm)
Providing, Laying, fixing & jointing of End caps (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(90mm)
Providing, Laying, fixing & jointing of End caps (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(110mm)
Providing, Laying, fixing & jointing of End caps (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(125mm)
Providing, Laying, fixing & jointing of End caps (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(140mm)
Providing, Laying, fixing & jointing of End caps (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete in all respect as per specifications, design, drawing and instructions of Engineer-in-charge.(160mm)
Supply and fixing of service saddle M.S. confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and pwd specifications and instructions of engineer-in-charge(90*50mm)
Supply and fixing of service saddle M.S. confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and pwd specifications and instructions of engineer-in-charge(110*50mm)
Supply and fixing of service saddle M.S. confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and pwd specifications and instructions of engineer-in-charge(125*50mm)
Supply and fixing of service saddle M.S. confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and pwd specifications and instructions of engineer-in-charge(140*50mm)
Supply and fixing of service saddle M.S. confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and pwd specifications and instructions of engineer-in-charge(160*50mm)
Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge(90mm)
Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge(110mm)
Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge(125mm)
Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge(140mm)
Supply and fixing of Flange tail end 4 kg with flange confirming to code with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respect as per design, pwd specifications and instructions of Engineer-in-charge(160mm)
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.(1 Unit Portable Air Compressor @250 psi & 300 cfm)
Any Other Items (as per CSR)
Ramesh Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .