Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | Admitted-Finance |
| 3 | Admitted-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
10 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Provn of Certain Sanctioned works at 223 ABOD and 23 FAD at Mil stn Suranussi under GE Kapurthala
2021_MES_432310_1
GEKPT-29/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹74,000
12 Apr 2021
22 Mar 2021
12 Apr 2021
22 Mar 2021
10 Apr 2021
25 Mar 2021
60 days
Amount
M & L for Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to copper earth stip of 20 x 3 mm flat brass by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
Supply & fix single pointed air termination aluminium rod 12 mm dia 300 mm long
M & L for Aluminium strip 25 mm x 3 mm complete with insulating material porcelin block saddles and welding/fixing screws for fitting the strip all as specified & as directed by Engr-in-charge.
Supply & fix for GI strip 32 mm x 6 mm with burried in ground all as dspecified and directed by Engr-in-charge.
Supply & fix for copper strip 32 mm x 6 mm with burried in ground all as dspecified and directed by Engr-in-charge.
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including, 3 NOS, 8mm dia 25mm long hex, head screw complete all as directed.
Supply and fix GI tubing medium grade with all fitting laid in trenches , road or wall for cable protection complete all as specified of size 40 mm bore.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in soft/loose sil for laying if GI pipe etc.
All as per item No. 08 above but depth exc 1.5 mtr and n.exc. 3.0 mtr in depth and getting out in soft/loose soil for laying of GI Pipe etc.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in padestal of pole /strut and in coping including use and waste of necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as specified and directed.
Supply , install, testing commissioning in replacement of factory made and tested outdoor type floor mounted LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet and 40X40X6mm thick MS angle iron frame work front opening type of adequate and easy maintenance size for housing LT switchgear in separate compartment and measuring instruments,locking arrangement , duly powder coated on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size and rating and comprising of followings:-
(a) Bus Bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding in separate sheet steel enclosure.
Incoming:-
(b) MCCB 415 Volts, 400 Amp rating 4 Pole , adjustable typeThermal Magnetic based release fixed for incoming supply with overload, short circuit and earth fault protection ( Service Breaking Capacity 35KA-1 No
(e) LED type Indicating lamps panel mounting type RYB-3 Nos
Outgoing
(f) MCCB 415 Volts, 200 Amp rating 4 Pole , adjustable typeThermal Magnetic based release incoming supply with overload, short circuit and earth fault protection ( Service Breaking Capacity 35KA -3 Nos
(g) MCCB 415 Volts, 125 Amp rating 3 Pole , adjustable typeThermal Magnetic based release for outgoing supply with overload, short circuit and earth fault protection (Service Breaking Capacity 25KA -3 No)
(h) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(j) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job.
(k) S&F power capacitor bank for improvement of power factor 3 phase, 440 Volt, AC, 50 Hz with copper bus bar heavy duty for non linear loads upto 10% to 20%, type MPP-H, in existing LT panel and making electrical connections by providing copper cable of suitable size, and lugs as directed, Make - L&T/Siemens or equivalent of Rating 80 KVAr
(l) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Supply , install, testing commissioning in replacement of factory made and tested outdoor type floor mounted LT panel board, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet and 40X40X6mm thick MS angle iron frame work, front and back opening type with adequate and easy maintenance size for housing LT switchgear in separate compartment and measuring instruments,locking arrangement , duly powder coated on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size and rating and comprising of followings:-
(a) Bus Bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding in separate sheet steel enclosure.
Incoming:-
(b) MCCB 415 Volts, 250 Amp rating 4 Pole , adjustable typeThermal Magnetic based release fixed for incoming supply with overload, short circuit and earth fault protection ( Service Breaking Capacity 35KA-1 No
(e) LED type Indicating lamps panel mounting type RYB-3 Nos
Outgoing
(f) MCCB 415 Volts, 200 Amp rating 4 Pole , adjustable typeThermal Magnetic based release incoming supply with overload, short circuit and earth fault protection ( Service Breaking Capacity 25KA -3 Nos
(g) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.
(h) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job.
(j) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B) /Stone/ PCC block work in CM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting blots etc for panel . The platform shall be of 450 mm height above ground level and of adequate size leaving minimum 300 mm all around the feeder pillar board for movements.
Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to copper earth lead of 20 x 3 mm flat brass by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
Supplying, Laying , Jointing, testing and commissioning XLPE UG cable, sheathed armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area complete and specied as directed by Engr-in-charge :- (Note : Excavation and earth work to be measured and paid separately.)
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
300 Sqmm 3.5 core
Excavation over areas in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
Removing excavated surplus soil (Soft/loose soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- 18 CM thickness of sand after punning down shall be measured, recorded & considered for payment.
UNITED ENGINEERING CORPORATION
M/s Sahib and Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .