Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹36.3 LAccepted-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹39.0 LRejected-Finance H NO 502 B BLDG WELWORTH PARADISE PANCARD CLUB ROAD OPP MARBEL SOCIETY NEAR DHANKUDE VASTI BANER PUNE MH 411045 | PUNE | PUNE | MAHARASHTRA | 411045 | SECOND | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
15 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
PROVISION OF ADDITIONAL ROOMS FOR TRAINEE OFFICERS AT AFTPS OF ASTE UNDER GE AF MARATHAHALLI
2024_MES_641954_1
8676/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹84,000
Yes
2 May 2024
12 Feb 2024
20 Mar 2024
12 Feb 2024
15 Mar 2024
26 Feb 2024
Amount
Removing demolised materials (debris) away from MoD land abiding to local guiding rules, complete as directed by Engr-In-Charge.
M&L for Cement concrete of 25mm thick , 1:2:4 type B-0 (12.5mm graded crushed stone aggregate as in sub-floors, complete all as specified.
M&L of Screed bed of cement mortar 1:6 or bedding layer of mortar 15 mm thick for laying floor finishes all as specified and directed.
S&F of light shade Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, Complete all as specified and directed.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Complete all as specified and directed.
M&L for painting new steel surfaces of any description including preparation, priming with red oxide zinc and two coats synthetic enamel paint, width or girth over 10cm not otherwise described, complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed.
Providing and fixing factory made uPVC white colour Sliding window Three track area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specifed and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured or payment purpose.)
S&F of Aluminium (Die Cast) Body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, etc. complete all as specified.
S&F providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular section / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required cluding cleat angle, Aluminium snap beading for glazing / architectural drawings and the directions of Engineer-in-charge complete all as specifed and directed.
S&F for stainless steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples to Aluminium Frames, complete and as directed.
S&F for 12mm thick particle board for insulation purpose, fixed to aluminium framework, complete all as directed.
Providing and fixing in position, 100 mm thick factory made expanded polystyrene core (EPS Core) wall panels consisting of EPS core sandwiched between two Engineered sheets of welded wire fabric mesh duly finished with shortcrete materials on outer faces. The fabric mesh shall be made of 3 mm dia zinc coated GI wire mesh with 50 mm pitch in both the directions and on both faces of the wall and connnected by GI wire of 3mm dia at alternate row by welding. The EPS core shall consist of 50 mm thick EPS of density not less than 16 kg/per cum. Both the outer faces of the panel shall be finished by applying the layer of 25 mm thick cement mortar 1:3 {1 cement 3 course sand (not having more than 40% stone chips of size upto 6mm)} with the help of shotcreting/ guniting equipment etc at a pressure not less than 1 bar (100KN/sqm) and both surfaces finished with trowel. Fixing operations of wall panels shall be completed in all respect as per drawings and specifications and under the overall direction of the Engineer-in-charge. Note: The work aginst this item shall be got executed through OEM or his authorised executing agency after approval of GE. The Contractor shall submit test reports and manufacturers certificate for materials, concrete mix design details etc and the cost the same shall be borne by the contractor. Make: ALPHA PEB/RAPIDCON/JSW/SRISTI VENTURES
S&F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600mm centre to centre and wall angle of size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre tegular edge ceiling tiles of RH90 complete all as specified and as directed. Make- Armstrong/Everest
S & F 20 mm bore CPVC pipes SDR 11 & plain CPVC SDR11 fittings on walls and ceiling or laying in floors, with all fittings complete all as specified.
M & L for preparation of old wall surfaces and applying one layer of internal wall putty, complete all as specified and as directed (Make: Birla / JK wall putty )
M & L for two coats of oil bound distember over one coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed.
M & L for preparation of old surface and applying one coat of oil bond distempering on walls complete all as specified and directed.
M & L for two coats of plastic emulsion paint over and including one coat of primer on old decorated surfaces of wall including preparation of surfaces by complete removal of existing treatment etc complete all as specified and as directed. (Make: Asian / Berger / Nerolac)
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each complete all as specified.
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
M&L for Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
Supply and fixing of GI tubing, light grade, 50 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / ZINDAL / Bansal .
Supply and laying cable XLPE insulated armoured,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3½ core connected with suitable legs including taking out the existing unserviceable cable complete all as specified.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure complete all as specifed and directed.
Supply, installation, testing and commissioning of outdoor type cubicle panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shared having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising. The outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front openable, double door system lockable/ open able. The bottom of the outer shell contains a detachable plate having size with glands. The outer shell shall be mounted on stand having zine coating not less than 80 microns. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP - 54. Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN alluminum bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleave. All control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs all as specified and directed by Engr in charge. Make:L&T,Legrand India Pvt Ltd,Standard
INCOMING (a) MCCB 400 Amps 50 KA - 01 No (b) Intelligent AC digital display three phase LCD ammeter 0 to 630A and voltmeter 0 to 500V with CT. (c) Indication lamp RYB/RRR-set of 03 -01 No
OUT GOING (a) MCCB 4 pole 200 Amps 35 KA 415 Volt - 1 No (b) MCCB 4 pole 32 Amps 16 KA 415 Volt - 2 Nos (c) MCCB 4 pole 160 Amps 35 KA 415 Volt - 1 No (d) MCCB 4 pole 100 Amps 25 KA 415 Volt - 5 No (e) Changeover of capacity 250 Amps - 1 No (f) Spare pocket for provisioning of MCCB - 1 No
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 3mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
Material & labour for fixing of Earth continuity conductor GI strip of size 25 X 3 mm with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed on with epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
Supply and fix cable tray for cable laying of size 20 cm x 5 cm complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in foundations for filling and mass concrete complete all as specified and directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /Fan point/ bell point controlled by one switch.
All as per item No.39 above but One 5 Amps socket point on same board with other switches
All as per item No.39 above but One 5 Amps socket point on independent board.
All as per item No.39 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .
All as per item No.39 above but wiring complete with 4.0 Sqmm for 3 pin 15/30 A socket multipurpose on independent board .
Material and Labour for ceiling rose 3 terminals complete all as specified & directed.
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing bell push flush type 5 Amps in replacement of old u/s complete all as specified & directed.
S & F in replacement Door bell AC, 230 volts, single pole in replacement of old u/s bell/ buzzer complete.
Supply and fixing 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified.
S&F in repair LED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
S&F in repair LED PC batten light fitting of 2 feet 10 watt, with energy efficient LED and integrated electronic driver of 10W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Taking down old u/s Ceiling/wall fittings of 1x11W/20W of any type, S & F LED fitting of 6 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 6W LED lamp complete all as specified. (Make: Bajaj /CG/Philips/Havells
S&F Celing Fan complete with blades , down rods ,electronic regulator and accessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed.
S&F in replacement douple pole and neutrla enclosure with two pin and earth plug and socket including 1Nos MCB 20 Amps capacity complete all as specified and directed by Engr-in-charge.
M & L for sub main wiring complete with two runs of 2.5 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with three runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S & F MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells / L&T / Legrand
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells / L&T / Legrand
S & F MCB TPN 63 Amps incl making connections all as specified and directed. Make -Havells / L&T / Legrand
S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells / L&T / Legrand
S & F MCB DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. Make -Havells / L&T / Legrand
S & F MCCB DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. Make -Havells / L&T / Legrand
Supply & fixing GI earth wire 4.00 mm dia for interconnecting of earth electrodes all as specified.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply and fixing 5.5 mm thick tinted sheet glass, ordinary quality and glazing with oil putty in square exe 0.5. sq.m in each panel fixed to aluminium frame work with necessary rubber beading complete all as specified and directed.
Ajinkya Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .