Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹38.4 L+₹52,627.50 (1.39%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹39.8 L+₹1.9 L (4.94%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Highest bid quoted | |
| 4 | L4₹44.6 L+₹6.7 L (17.6%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted |
Tender Value
₹48.6 L
EMD Value
₹98,000
Closing Date
15 Sept 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
ADDITIONAL ALTERATION TO PATHWAY OF AERIAL PARK AT NTS SPECIAL REPAIR TO REPLACEMENT OF BER SUBMERSIBLE PUMPS AND OTHER ALLIED WORKS AT VSV PROVN OF DRAIN PIPE FROM BALCONIES OF SMQs IN OLD WAPITI AND OLD CAMP AT AFSSR PROVN OF STEEL GATE AT NTS ADDN
2021_MES_469048_1
CA NO GE/GUR-/NIT-40/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹98,000
11 Nov 2021
18 Aug 2021
17 Sept 2021
18 Aug 2021
15 Sept 2021
1 Sept 2021
Amount
1. Supply, connecting, lowering, testing and commissioning of Energy efficient Submersible pump set complete of capacity 300 to 350 LPM, 120 M head with suitable capacity of (but not less than 10 HP) elctric motor, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) complete with stainless steel body and impeller, diffuser & diffuser casing complete with MS iron hooks- 02 Nos welded at the top of motor head & pump suitable tie SWR rope for anchoring complee all as specified and directed at site by Engr-in-Charge.
2. Supply, connecting, lowering, testing and commissioning of Energy efficient Submersible pump set complete of capacity 300 to 350 LPM, 120 M head with suitable capacity of (but not less than 12.5 HP)elctric motor, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) complete with stainless steel body and impeller, diffuser & diffuser casing complete with MS iron hooks- 02 Nos welded at the top of motor head & pump suitable tie SWR rope for anchoring complee all as specified and directed at site by Engr-in-Charge.
3. Supply, connecting, lowering, testing and commissioning of Energy efficient Submersible pump set complete of capacity 400 to 450 LPM, 130 M head with suitable capacity (but not less than 7.5 HP)of elctric motor, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) complete with stainless steel body and impeller, diffuser & diffuser casing complete with MS iron hooks- 02 Nos welded at the top of motor head & pump suitable tie SWR rope for anchoring complee all as specified and directed at site by Engr-in-Charge.
4. Supply, erection, testing and commissioning of factory assembled and tested electric motor driven thee phase 415 Volt AC, 50 Hz , Centrifugal type water pump set capable of delivering not less than 900 LPM of water as at minimum 30 mtr head and capacity not less than 10 HP comprising of heavy duty type split casing type centrifugal pump, Cast iron body with bronze impeller, casing ring, sleeves etc . coupled to TEFC electric motor of suitable capacity1500 RPM by means of flexible coupling and mounted on a common fabricated MS base frame and GI pipe heavy duty at suction and GI heavy duty delivery pipe of suitable size as reccomended by manufacturer upto suitable lenghth at suction end and delivery connection to header with necessary fittings . NOTE-(i) Cost of GI pipe heavy duty at suction and GI heavy duty delivery pipe of suitable size as reccomended by manufacturer upto suitable lenghth at suction end and delivery connection to header with necessary fittings shall be included in overall cost quoted(iii) (iii) COST OF FOUNDATIONS AS PER MANUFACTURERS RECCOMMENDED DRAWING WITH NUTS, BOLTS, ANTI VIBRATION PADS INCLUDED IN OVERALL RATES QUOTED
5. Supply, installing, testing and commissioning Non clog vertical submersible pumps, electric driven 415 Volt, TP complete of size 5 HP discharge/flow 600 LPM and head 25 mtr with chrome steel impeller and cutter, non-clog to pass 40 mm size particles as per Kirloskar Model No with ETERNA-4000CWC and Cat No T11SY05000801042 complete all as specified and directed.
6. Supply and fix Servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5%, 50 Hz, and speed of correction 8 Volts per second, Unbalance type, Copper wound, Digital Display type, relay free smooth and silent operation with Ist filling of Transformer oil, no distortion in wave form, response time not o exceed 10 mille seconds with over load/short circuit protection, High/low voltage cut off, by pass arrangement in case of emergency, single phase sequence change protection etc confirming as BIS : 9815, Part I : 1994 reaffirmed 2009 of capacity 20 KVA, complete all as specified and directed.
7. M&L for Earthing complete with galvanished steel earth plate electrode 60cm x 60cm x 6.00 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanished iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
8. Supply and fixing of flat submersible 3 core 4 Sqmm cable PVC insualted, unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
9. Supply and fixing of flat submersible 3 core 6 Sqmm cable PVC insualted, unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
10. S & F GI Coloumn pipe of bore 40 mm and 6 meter length with socket/flange of size 40 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts, gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
11. S & F GI Coloumn pipe of bore 50 mm and 6 meter length with socket/flange of size 50 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts, gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
12. S & F GI Coloumn pipe of bore 80 mm and 6 meter length with socket/flange of size 80 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts, gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
13. Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 50 Sqmm x 3.5 core complete all as directed. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.
14. S & F Cast Iron Non eturn valv of size 80mm dia, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed by Engr in charge.
15. Supply and fixing Direct-on-line (DOL) starter ML1.5 DOL type suitable for upto 5 HP to 7.5 HP summersible/monoblock pump motor set AC 440V 50 Hz with single phase priventor over current, short circuit protection complete with sheet metal enclosure including fixing/mounting as per L&T Cat No SS91854POAO complete all as directed and specified. Make L&T/ BCH/Siemens
16. Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc in soft/loose soil, n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, complete all as specified and directed by Engineer-in-Charge.
All as above item No 16 but in hard / dense soil
17. Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete. all as specified & directed by Engineer-in-Charge.
18. Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge .
19. Supply and laying, sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
20. M&L, for providing dry river sand as in sand cushioning to UG cable and paver block including punning gently all as directed.
21. Lifting and lowering submirsible pump moter/Non clog pump under Ser item No 1 to 3 & 5 above with the help of machine/ hydra/chain pully block with sufficent manpower & proper size . flanges for safe working of submersible pump with motocomplete all as specified and directed by the Engr-in-Charge. Note:- During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
Demolition of cement concrete in ground floor and pavings n exc 15 cm thickness (below of above ground level) incl tiles and removing the rubbish outside MOD Land complete all as specified.
M&L for 75mm thick PCC (1:4:8), type D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring etc complete all as specified and as directed
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment over 25mm thick sand cushioning (sand to be measured and paid saperately) complete all as specified and as directed.
M&L for providing, cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed
M&L for PCC (1:4:8), type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:6 etc complete all as specified and as directed
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick masonry or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed
M&L for applying two coats of cement base paint on newely plastered or old untreated surfaces of walls including preparation complete all as specified and as directed
M&L for Pre cast cement concrete 1:2:4 Type B-1 using 20mm graded stone aggregate set in cement mortar 1:4 as in Manhole covers , shelves and similar items complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
M&L for TMT bars 6 to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
M&L for TMT bars 5 mm dia and over, upto and including 10 mm dia as in stirrups, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
Use and waste of formwork to sides of concrete, foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of rough finished flat surfaces of beams, giders, lintels , cantilever slabs etc complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of rough finished flat surfaces of suspended slabs such as roof slabs , floor slabs , landings and similar works not exceeding 200mm thick ( horizontal or sloping ) etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) for columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) as in beams , cantilevers , bressumers , lintels over 1.5 m span etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) as in slabs supported on walls , beams and columns in floors , roofs , landings , balconies etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 (using 20mm graded crushed stone aggregate) as in chajjas etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (Nominal Mix) 1:1.5:3 type A1 (using 20mm graded crushed stone aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (Nominal Mix) 1:1.5:3 type A1 (using 20mm graded crushed stone aggregate) for columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L for febrication and fixing of Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engr-in-Charge
S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410 Gde-E-250 quality A complete all as specified and directed by Engr-in-Charge
M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed.
Cutting holes into or through bricks walls built in Cement mortar or RCC Walls and making good and incasing of pvc pipe in cement mortar 1:3 and cement concrete 1:2:4 type B1 as required suerficial area n.exe 150 sqcm.
S&F 75mm bore PVC(SWR) pipes single socketed in any length pressure rating 4Kg/Sq cm medium Grade with rubber ring joints fixed to walls with dash true nut and bolt complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) Junction single,(single Y/T) equal or unequal complete all as specified and directed by Engineer-in-charge.
S&F Grating doom 75 mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engineer-in-charge.
S&F Stack clamps for 75mm pvc SWR pipes made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone agggregate as in surface channel drain and bedding including necessary form work and weathering, slightly rounded or chemfered angles complete all as specified and directed.
Demolition of cement concrete (reinforced ) of any description and in any position not specially provided for including tiles and removing the rubbish outside MOD Land complete all as specified.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise
Taking down Chowkat or frames with shutters(without taking off shutters from the frames) exc 1.5 but n.exc 4.00 sqm each
M&L for damp proof course using PCC (1:2)4 ) type B-0, 40mm thick including applying a coat of blown bitumen @ 1.5 g /sqm and blinded with clean dry sand @ .05cum per sqm complete all as specified and as directed
M&L for 50mm thick PCC (1:4:8), type D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring etc complete all as specified and as directed
M&L for 25mm thick PCC (1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick screed bed or bedding layer in CM 1:4 for laying floor finish complete all as specified and as directed
M&L for ATT ( pre construction ) treating the bottom and sides of excavation @ 5 Litre of emulsion / sqm of surface area complete all as specified and as directed
M&L for ATT ( pre construction ) treating the back fill in contact with foundation @ 7.5 Litre of emulsion per sqm of vertical surface complete all as specified and as directed
M&L for ATT ( pre construction ) treating the top surface of filled earth @ 5.00 Litre of emulsion per sqm complete all as specified and as directed
M&L for ATT ( pre construction ) treating the soil under plinth protection @ 5.00 Litre of emulsion per sqm complete all as specified and as directed
M&L for 10mm thick Rendering on ceiling surface fair faces of brick work or concrete sureces in Cement Moratar 1:3 finished surface even and smooth without using extra cement as specified and as directed.
M&L for 15mm thick Rendering on fair faces of brick work or concrete sureces in Cement Moratar 1:6 finished surface even and smooth without using extra cement.as specified and as directed
S&F for windows section frame 72x55mm fixed to wall or concrete surface with rawl plug made of galvanised steel powder coated section of shutter 47x20mm , mullion section 72x50mm ( base steel as per IS 513 D quality galavanised as per IS 277 with zinc of 120 gms / sqm) , glazed or gauged and wire gauge shutter prepared to receive wire mess to shutter ( double door ) with total coating thiickness of 0.6mm including grills / guard bars made of square bars powder coated fixed to windows frame with screws at 150mm c/c bothways , 4 to 5 mm thick sheet glass , 0.36mm stainless steel wire cloth with 1.40mm aperture including necessary fittings and builders hardware such as handles , tower bolts , stays etc complete all as specified and as directed
M&L for 75mm thick PCC (1:3:6), type C1 (using 20mm graded crushed stone aggregate) as in plinth protection etc complete all as specified and as directed
M&L for preparing the new concrete / plastered surfaces by cleaning thoroughly by wire brush and applying a coat of bituminous primer conforming to IS 3384-1986 @ .30 litre /sqm then laying 3mm thick APP membrane modified prefafricated with non woven polyster reinforcement five layered weighing not less than 3.6 Kg per sqm comprising of centre core of 160-170 gsm non wven polyster matt sandwitched on both sides by APP polymer modified bitumen duly protected on both sides by 20 micron HMHDPE film by torch application with gas welding torch ( Butne torch ) and thereafter applying a tack coat of 85/25 blown bitumen conforming to IS 702 @ 1.2 kg per sqm etc complete all as specified and as directed ( Note : WPT work shall be done through authorised applicator only
M & L for prepring new plaster surfacs of walls and applying two coats of plastic emulsion over a coat of primer complete all as specified and directed.
M & L for prepring new plaster surfacs of ceiling and applying two coats OBD over a coat of primer over a layer of 3mm thick wall care puttyprimer complete all as specified and directed.
M & L for prepring new plaster surfacs of ceiling and applying two coats exterior emulsion paint over a coat of primer over a layer of 3mm thick wall care puttyprimer complete all as specified and directed.
M & L for vitrified tiles 10mm thick ( square or rectangular ) of light shade , area of each tile not exceeding 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and including 20mm thick screed in CM 1:6 complete all as specified and directed.
Excavating in post holes ( or similar holes ) in hard / dense soil each not exceeding 0.50 cum including getting out and returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing the surplus soil complete all as specified and directed by Engineer-in-Charge.
S&F rolled sections , MS angles , MS tubular structures , MS channels , Tee etc ( Fe 410-W grade - E 250 quality ) as in main and cross beams , hip rafters , purlins where conncted to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete, complete all as specified and directed by Engr-in-Charge
M&L for preparing old painted steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enemal paint complete all as specified and directed.
M&L forpre painted galvalume aluminium zinc coating GI based corrugated steel sheets0.50mmthick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to walls fixed with self tapping screws complete all as specified and directed.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed FRLSH Grade cable 1100 volts grade confirming to IS: 694 for phase and neutral drawn in and including medium duty concealed PVC conduit confirming to ISI marked not less than 20mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :-
One light point controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One fan point/Exhaust fan controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One 5 pin socket oulet 5/6 amps on same board including single core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth dolly all as specified.
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sqmm of size all as specified and directed.
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed FRLSH cable 1100 volts grade confirming to IS: 694 drawn in and including medium grade concealed PVC conduit confirming to ISI marked not less than 25mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 4 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for one 6 pin socket outlet two in one 16/6 Amps on an independent board. (for geysers point) Note : 1) For item No 84,85,86 Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. No Extra payment will be done on this account
-Ditto- but with cable 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm stranded copper unsheathed complete all as specified and as directed.
Supply and fix in repairs switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
Supply and fixing in repairs socket outlet 2 in 1, 3 pin 5 Amps all as specified and directed at site.
Supply and fix switch in repairs switch and socket combination 5 Amps/16 Amps, 5 in 1, flush type all as specified and directed at site.
Supply and fix in repairs ceiling roses, 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply and fix in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed at site.
Supply and fix in replacement of 20 watt (4ft long) decorative box type fitting with blue coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
Supply and fix in replacement MCB, DB , SPN 8 way suitable for single phase 240 volts with 100 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCB's single/double pole complete all as specified and directed at site.
Supply and fixing in replacement of MCB signle pole 6-32 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fixing in replacement of MCB single pole and neutral 40 /63 Amps 230 volts 'B' series complete all as specified and as directed at site.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and directed by Engineer-in-Charge. Make:- Model No 607841 of Make Legrand or equivalent in Siemens/Hagger/L&T.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
Supply and fixing of ceiling fan 1200mm sweep 230Volts complete with electronic step type regulator 5 star rating and accessories as required for hanging, mounting complete as specified and directed by Engr-in-Charge. Model ES-40 Make:- Havells or equivallent model in Bajaj/ CG/ Usha
P R Constructions
akhil enterprises
M/S GEETANJALI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .