Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.7 LAccepted-AOC H NO 71 85 B1 WARD NO 7 NR AGRICULTURE OFFICE VALPOI SATTARI GOA | ₹59.7 L Quoted ₹70.5 L | L1 | Accepted-AOC Lowest bidder accepted |
| 2 | L2₹72.0 LRejected-Finance | ₹72.0 L | L2 | Rejected-Finance L2 Rejected |
| Sl No | Description | Qty | Unit | sumitra construction L1 | M/S DOUBLE CENTURY CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00 | Transportation and carriage (A) By tipper truck including loading, unloading and stacking(A) Lime,building rubbish, manure sludge, moorum excavated rock( i ) Lime,moorum, building rubbish upto 20km | 13 | cum | 570 ₹7,410 | 581 ₹7,553 |
| 2.00 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.a)All kinds of soil | 24 | cum | 299 ₹7,176 | 306 ₹7,344 |
| 3.00 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. | 7 | cum | 2,277 ₹15,939 | 2,321 ₹16,247 |
| 4.00 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. | 55 | cum | 5,341 ₹2.9 L | 5,445 ₹3.0 L |
| 5.00 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement,in superstructure from floor I level upto floor V level | 131.4 | cum | 6,298 ₹8.3 L | 6,420 ₹8.4 L |
| 6.00 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing :a)All works upto plinth level | 19 | cum | 6,834 ₹1.3 L | 6,966 ₹1.3 L |
| 7.00 | Centering and shuttering including struttings, propping etc. and removal of formwork for :Foundations, footings, bases for columns and mass concrete. | 12 | sqm | 419 ₹5,028 | 427 ₹5,124 |
| 8.00 | Centering and shuttering including struttings, propping etc. and removal of formwork for :b)vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. | 38.4 | sqm | 493 ₹18,931.20 | 503 ₹19,315.20 |
| 9.00 | Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | 55 | sqm | 834 ₹45,870 | 850 ₹46,750 |
| 10.00 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c)In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level | 3 | cum | 7,839 ₹23,517 | 7,991 ₹23,973 |
Tender Value
₹68.5 L
EMD Value
₹1.4 L
Closing Date
22 May 2025, 4:00 pmClosed
EE,SCD
SOIL CONSERVATION DIVISION DIRECTORATE OF AGRICULTURE KRISHI BHAVAN TONCA-CARANZALEM-GOA
RENOVATION OF BUILDING OCCUPIED BY FARM SUPERINTENDING OF KALAY FARM, AND OTHER WORKS AT KALAY FARM, KALAY SANGUEM GOA
2025_DAG_22511_1
SCD/D.A./25-26/e46/L2/119
Open Tender
Civil Works
KALAY FARM, KALAY SANGUEM GOA
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,000
₹1.4 L
24 Feb 2026
5 May 2025
23 May 2025
5 May 2025
22 May 2025
7 May 2025
Amount
Transportation and carriage (A) By tipper truck including loading, unloading and stacking(A) Lime,building rubbish, manure sludge, moorum excavated rock( i ) Lime,moorum, building rubbish upto 20km
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.a)All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement,in superstructure from floor I level upto floor V level
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing :a)All works upto plinth level
Centering and shuttering including struttings, propping etc. and removal of formwork for :Foundations, footings, bases for columns and mass concrete.
Centering and shuttering including struttings, propping etc. and removal of formwork for :b)vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc.
Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c)In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
Centering & shuttering including Strutting, Propping & removal of forms for :Suspended floors, roofs landings, shelves & their supports
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon.b)Second class Indian teak wood
Providing & fixing 20 mm eaves barge boards 2nd class matti wood
Providing and fixing 38 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including anodized aluminium butt hinges with necessary screws:A)Second class Indian teak wood
Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.b)40 x 3 mm flat iron hold fast, 15 cm long
Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws.b)ornamental grill
Providing and fixing bright finished brass handles with necessary screws etc completeA)125MM
Providing and fixing bright finished brass door latch with necessary screws etc completea)300x 16 x 5 mm
Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete.
Providing and fixing chromium plated brass sliding door bolt with bolts, nuts and screws etc. complete.a)300 x 16 mm
Providing and fixing aluminium tower bolt (barrel type) anodised or dyed to required colour or shade with screws etc. complete.c)200x10mm
TWO TRACK SLIDING WINDOW (Heavy):-Providing & fixing Two Track sliding window Yashashri make or equivalent, in heavy sections made out of 104mm x 51 mm x 2.5 mm Upvc multi cavity track section & shutter made out of 45mm x54mm x 2.5mm Upvc multi cavity section welded in corners with Glass beading & EPDM Gasket & 4mm clear glass with lock & rollers. The average weight of Two Track Sliding window (Heavy) is 16.75 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods.
Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only)in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paintb)In tees, angles, flats and channels
Providing and fixing M.S. fan clamp type 1or II of 16 mm dia M.S. bar bent to shape with hooke ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows in figured glass and powder coating with pure polyester powder of shade of required colour on the aluminium section
Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge.
providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth above 610mm) including all the accessories complete as per the directions of the Engineer in charge.
Providing & fixing in position Galvalume/Zincalume flashings, cappings, ridges, gutters upto 600mm/610mm girth and min 3.00m in length (cold Rolled Steel 550 MPa yeild Stress ASTM A 446 Grade E) with hot-dip metallic coating of aluminium-zinc alloy(AZ 150 galvalume) (150 gms/sqm total of both sides with Al-Zn Composition= 55% & 43.5% resp. & 1.5% Si conforming to ASTM 792/ AS 1397) 0.45 mm base metal thickness and 0.50mm total coated thickness, factory cut at all heights for roof, side & gable cladding complete in all respects with AZ 150 GSM SMP color Coated (20mic exterior coat of Silicon Modified Polyester paint system over 5 mic primer and 5 mic polyester back coat over 5 mic primer) incl. fixing to purlins with no 12x14x55mm mechanically galvanised hex head self drilling screws of the best quality as per AS-3566 class 3-4 approved, which should be compatible to be used with sheets. with integral washers and EPDM seals etc. Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed.
Providing water proofing treatment over the newR.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.
20mm cement plaster 1: 3 (1 cement : 3 fine sand)
6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Applying one coat of distemper primer of approved brand and manufacture on wall surface.
Painting 2 coats with oil type wood preservative of approved brand & manufacture on new work.
Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in all shade or new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Fixing doors chowkhat in existing opening including embedding chowkhats in floor, cutting masonry for hold fasts embedding hold fast in cement concrete blocks with cement concrete 1:3:6 (1 cement ; 3 coarse sand : 6 graded stone aggregate 20mm nominal size) painting two coats of coal tar to sides of chowkhats and making good the damages to walls & floors complete including disposal of rubbish to the dumping ground within 50mts. lead.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mts. lead.
Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead.
Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt.lead A) area 3 sq.m. and below
Dismantling asbestos sheet roofing including ridges, hips valley and gutters and stacking the material within 50 meters lead.
Dismantling tiled roofing (mangalore or pot or country tiles) with battens etc. complete including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.
Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required.a)Flat back wash basin size 630 x 450mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers.
Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screwsb)600 x 20 mm size
Making connection of G. I. Distribution branch with G. I. Main 50 mm to 80 mm nominal bore by providing and fixing tee including treading the pipe etc. complete
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality :d)32 mm nominal bore .
Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1: 1 1/2:3 mix (1 cement: 1 1/2 coarse sand ;3 graded stone aggregate 20mm nominal size foundation concrete 1:1 1/2:3 mix (1 cemet ;1 1/2 coarse sand :8 graded stone agrregate 20mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. b)Inside size 90 x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg.)
Making soak pit, 2.5 m dia 3 m deep with 45 x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter,1.8 m long complete filled with laterite stone aggregate 125 to 180mm surrounded by laterite stone aggregate of 40mm and down guage as per standard design.
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:a)110 mm dia
Providing and fixing rigid PVC bend of required degree(of approved make ) for S.W.R. drainage pipes of approved including lubricating a)110mm dia
Providing and fixing U.P.V.C. pipe clips (approved make ) for S.W.R. pipes b)110 mm dia
Providing and fixing R.P.V.C. vent cowl:b)75 mm dia
Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993
Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe) f) 50 mm dia nominal outer dia pipes.
Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore:c)45 cm (18”) length .
Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. b) Post-construction
An elastomeric, cementitious, waterproof coating for concrete and masonry.Providing and applying on a well prepared vertical surface Masterseal 550EL of BASF make or equivalent elastomeric flexible, two component polymers modified cementitious composite system that requires no addition of water at the site. The product shall be applied in minimum two coats to achieve total DFT of 1mm. The material shall be mixed and applied fully in accordance with the manufacturer's instructions. The product shall exhibit at least 40% elongation at ambient & 30% elongation in under water condition with tensile strength greater then 20 Kg/cm2. The product shall resist 1.5 bars pressure when tested as per DIN 1048 at 2mm DFT. When applied at 2mm DFT, elastomeric coating shall be able to bridge crack up to 0.5mm width. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete.
Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in recessed PVC conduit (heavy) with modular switch, modular plates, suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.(C) Group A -- with Cat C Modular Accessories
Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLSPVC insulated copper conductor single core cable insurface PVC conduit( medium) alongwith 1 No 4 sq.mmFRLS PVC insulated copper conductor single core cable forloop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wirewith the following sizes of FRLS PVC insulated copperconductor single core cable in the independent surfacePVC conduit ( medium)of appropriate size as required.b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing )
Supplying and fixing following modular switch/socket on the existing modular plate and switch boxincluding connections but excluding modular plateetc. as required(a) 5/6 A switch Cat A
Supplying and fixing following modular switch/socket on the existing modular plate and switch boxincluding connections but excluding modular plateetc. as required(d) 3 pin 5/6 A socket outlet Cat A
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required(a) Cat A
Supplying and fixing following size modular PVC boxalongwith modular base and cover plate formodulator switches in recess etc. as requireda)(a) 1 or 2 Module Cat A
Supplying and fixing following size modular PVC boxalongwith modular base and cover plate formodulator switches in recess etc. as requireda)(e) 8 Module Cat A
'Installation, earthing, testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FR PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge includingpainting etc as required
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess completewith tinned copper busbar neutral busbar earth bardinnbar detachable gland plate interconnectionsphosphotized and powder painted including earthingetc. as required (but without MCB/RCCB/Isolator)8 way single door Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(b) SPN, Cat A
Supplying and fixing following rating double pole 240 V isolator,in the existning MCB DB complete with connections testing and comissioning etc. as required(a) 40 A, Cat A
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thickincluding accessories and providing masonryenclosure with CI/RCC cover having locking/Liftingarrangement and watering pipe etc. (but without charcoalor coke and salt) as required as per the Earthing Drawingprovided by the Engineer-Incharge.The scope of workincludes the following: a) Excavation of pit of size 1.0x1.0x3.0 mtrs(min) and disposal of excavated soil. c)WateringGI pipe, 20mm, Class B, with funnel as per specs. d)Charcoal/salt as per specs ( paid seperately). e) Refillingthe pit of size 1.0x1.0x 3.0 mtrs(min) with soft blackagriculture soil of minimum resistivity i/c transportation.e)Masonary chamber with proper foundation, cover plateand locking arrangement. f) Testing of earth value withearth megger and certifications of its value. Aluminium tagwith embossed earthing value to be attached to thepipe.g)watering arrangement(plumbing will be paidseperately).In soily strata
Extra for using salt and charcoal for GI or copper plateearth electrode as required( 96 Kgs of Charcoal and 5 Kgs OF salt
Providing and laying earth connection from earth lectrodewith4 mm dia copper wire in 15 mm dia GI pipe from earth Metreelectrode as required
Supply and erecting of 56 inch ( 1400mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. '(a) Cat A
Supply and erecting meter box suitable forsingle phase energy meter and incomingSP/DP MCB, fabricated out of 16 SWG sheetsteel, powder coated, complete as requiredand conforming to the requirements of GoaElectricity Department.
Supply,installation,testingandcommissioning of electronic type single phaseenergy meter (KWh), ISI marked, inpolycarbonate or sgheet steel body ( basemounting type) with counter display/LCDdisplay, with ELT, in Class 1.0, 50 Hz, 240 V.AC duly tested by MRT along with TestCertificates, complete as required of followingcapacity of make L & T only.(b) 10 to 40 A
Supply of2 core armoured PVC/XLPEinsulated, PVC sheathed copper conductorcable of 1.1 KV grade with ISI mark conformingto IS:1554(Part I) ,IS:7098(Part I) with latestamendments of following size.2 Core 6 sq.mm
Supplying installation testing and comissioning of 22wLED surface and wall mounted LED batten-tube of make jaquar(cat no.Commercialm indoor series glaza ultra aluminium,item code LGLZU1X022XN ) of jaquar or equivalent make complete as required and approved by enginerr-in charge.
M/S DOUBLE CENTURY CONSTRUCTIONS (BID ID -48254)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid