Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹28.1 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance | ||
| 2 | L2₹30.6 L+₹2.5 L (8.83%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹34.1 L+₹6.0 L (21.2%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | Not Admitted-Fee/PreQual/Technical 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | ||
| 5 | Not Admitted-Fee/PreQual/Technical N A | NA | NA | 121004 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹51.1 L
EMD Value
₹1.0 L
Closing Date
20 Jan 2026, 3:00 pmClosed
Executive Engineer (Elect.)
EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park
SH-Maintenance of EI and fans, Operation of pump set and electrical installation)
2026_PWD_284819_1
79/EE(E)/PWD NES ED/2025-26 (Recall)
Open Tender
Electrical Works
Percentage
365 days
nand nagari
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.0 L
Yes
23 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
Day to day operation & maintenance of Sub Station, HT, LT panel transformer dry type, DG Set, Storm Water pumps by Pdg services of qualified & experienced staff on all working days Excluding Sundays & holidays, general upkeep of all etc. as reqd. Wireman cum Operator – 3 No. (Round the Clock) Khallasi - 3 No. (Round the Clock)
Day to day Operation & routine maintenance of Electrical Installation & fans, compound light i/c drinking water pump, fixtures with allied work such as cleaning the light fittings, switch room, main switch board, ceiling fans, repair work connected with fans, fittings & fuses, oiling and greasing of pump set etc. as required and Operation and day to day maintenance of pump set by providing services of qualified and experienced staff on all days excluding Sunday and holidays i/c cleaning of pump set, general upkeep of pump house, starter panel all etc. as reqd. Wireman cum Operator – 2 Nos. (9.00 AM to 5.00PM) Khallasi - 2 Nos. (9.00 AM to 5.00PM)
Operation of VRV/VRF by providing services of qualified and experienced staff in General shift excluding Sunday and holidays i/c cleaning/ minor repair of VRV/VRF etc. as reqd. a) A.C/VRV/VRF Mechanic - 01 No. (9AM to 05PM) b) A.C/VRV/VRF Helper - 01 No. (9AM to 05PM)
Supplying and Fixing of Ventilating Exhaust fan upto 250mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Replacement of defective wall fan by Supplying Installation, testing & commissioning of wall fan 400 mm sweep in the existing surface and making good the damage, making connections, interconnections, earthing etc. as required.
Replacement of defective by S.I.T.C. of electric ceiling fans 1200mm sweep shall be capacitor type, with double ball bearing complete with capacitor, 300mm down rods, canopies, three number blades made of aluminum alloy, suitable for operation on single phase, AC 230 volt, 50Hz supply and but without regulator.
Replacement of defective exhaust fan by Supplying and Installation of exhaust fan 375-380mm sweep 900 RPM in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning i/c dismentling the existing etc. as required.
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 1.7 centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum ower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).40 Watt
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 18- 22 watt
S & fixing 3 x 10 sqmm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
S & fixing 4 x 16 sqmm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Replacement of defective Switch/socket by Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Replacement of defective box by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess i/c dismentling the existing etc. as required 3 Module (100 mmX75 mm)
6 Module (200mmX75mm)
12 Module (200mmX150mm)
Replacement of defective by Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
8 way, Double door
12 way, Double door
Replacement of defective by Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 kA,TPMCCB
250 A, 25 kA,TPMCCB
Replacement of defective by Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
12 way (4 + 36), Double door
Replacement of defective by Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Replacement of defective by Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp.
Replacement of defective by Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Lowering of submersible /mono submersible/ centrifugal pump set Upto 20Hp rating along with G.I /MS Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Lifting of submersible /mono submersible/centrifugal pump set Upto 20Hp rating along with G.I /MS Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Repairing overhauling & Rewinding of up to 5 HP submersible /Monoblock Pump motor set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos O-Ring, 16nos Ss Stad, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd i/c Less Credit of dismantle material.
Repairing overhauling & Rewinding upto 10 HP submersible /Monoblock/sewage Pump motor set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos O-Ring, 16nos Ss Stad, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd i/c Less Credit of dismantle material.
Repairing overhauling & Rewinding of 20 HP Centrifugal pump Motor set i/c replacement of all burnt parts etc. i/c reassembling and reinstall at site testing, commissioning etc. complete as reqd. i/c Less Credit of dismantle material. .
Less on account of buy back of dismentle material. Assorted Cooper wire
Assorted LED 2x2 / Batten Fitting
Assorted Celling fan/Exhaust fan
Assorted G.I box, Conduit, MCB, DB, Switch Socket, Regulator & XLPE Cable etc.
Assorted Wall fan/Ventilation fan
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.14 MB
BOQ_376732.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .