| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹36 L+₹3.6 L (11.0%)Admitted-Finance 55 KENCHAPPA ROAD FRAZER TOWN BANGALORE BANGALORE KARNATAKA 560005 | BENGALURU URBAN | KARNATAKA | 560005 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Not meeting the NIT eligibility criteria of bidding capacity. |
| Sl No | Description | Qty | Unit | TF Air Systems Pvt Ltd L2 | Sri Bhavani Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive annual maintenance of 35 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 3 | No. | 1,63,500 ₹4,90,500 | 87,500 ₹2,62,500 Lowest |
| 2.00 | Comprehensive annual maintenance of 30 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 2 | No. | 1,35,000 ₹2,70,000 | 75,000 ₹1,50,000 Lowest |
| 3.00 | Comprehensive annual maintenance of 25 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 6 | No. | 1,12,500 ₹6,75,000 | 62,500 ₹3,75,000 Lowest |
| 4.00 | Comprehensive annual maintenance of 16.5 TR floor mounted ETA & Blue star make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 6 | No. | 74,250 ₹4,45,500 | 41,250 ₹2,47,500 Lowest |
| 5.00 | Comprehensive annual maintenance of 15 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 1 | No. | 67,500 ₹67,500 | 37,500 ₹37,500 Lowest |
| 6.00 | Comprehensive annual maintenance of 8.5 TR Hitachi make ductable air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 2 | No. | 38,250 ₹76,500 | 21,250 ₹42,500 Lowest |
| 7.00 | Comprehensive annual maintenance of 3TR ceiling mounted cassette type air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 7 | No. | 13,500 ₹94,500 | 7,500 ₹52,500 Lowest |
| 8.00 | Comprehensive annual maintenance of 2 TR wall/floor mounted split type air conditioning unit (Copper condenser coil). The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 7 | No. | 7,200 ₹50,400 | 5,000 ₹35,000 Lowest |
| 9.00 | Comprehensive annual maintenance of 1.5TR/2TR ceiling mounted cassette type air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 2 | No. | 7,200 ₹14,400 | 3,750 ₹7,500 Lowest |
| 10.00 | Comprehensive annual maintenance of 1.5 TR wall mounted split type air conditioning unit(Aluminium condenser coil).The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils. | 36 | No. | 7,200 ₹2,59,200 | 3,750 ₹1,35,000 Lowest |
Tender Value
₹36.4 L
EMD Value
₹72,836
Closing Date
18 Jun 2025, 4:00 pmClosed
Project Director, FRFCF
Office of the Project Director, FRFCF-NRB, Kalpakkam.
Comprehensive annual maintenance of split (wall mounted and cassette type) and ductable package air conditioning units installed at FRFCF site, Kalpakkam
2025_BARC_861838_1
BARC/FRFCF/MECH/ACV/2024/T-069
Open Tender
Support/Maintenance Service
Item Rate
365 days
FRFCF, KALPAKKAM
Please refer tender document
8 documents required · 8 mandatory
₹0
₹72,836
22 Aug 2025
28 May 2025
25 Jun 2025
28 May 2025
18 Jun 2025
30 May 2025
29 May 2025 - 16 Jun 2025
Amount
Comprehensive annual maintenance of 35 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 30 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 25 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 16.5 TR floor mounted ETA & Blue star make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 15 TR floor mounted ETA make packaged air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 8.5 TR Hitachi make ductable air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 3TR ceiling mounted cassette type air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 2 TR wall/floor mounted split type air conditioning unit (Copper condenser coil). The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 1.5TR/2TR ceiling mounted cassette type air conditioning unit. The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 1.5 TR wall mounted split type air conditioning unit(Aluminium condenser coil).The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Comprehensive annual maintenance of 1.5 TR wall mounted split type air conditioning unit (Copper condenser coil). The scope of work includes quarterly preventive maintenance, attending periodical service, breakdown calls, repair and replacement of all spare parts (i.e including compressors, fans, elcctrical & communication cables between IDU,ODU and control panels, etc...) except Condenser & Evaporator coils.
Dismantling and shifting of 1.5 TR, 2 TR & 3 TR split AC units. The scope of work includes safe dismantling, shifting and storing of IDU, ODU, copper tubes with accessories.
Shifting and Installation of 1.5 TR, 2 TR & 3 TR split AC. The scope of work includes fixing of IDU, ODU, copper tube & electrical cabling between IDU & ODU with necessary accessories, condensate drain, making holes on walls, filling white cement, pressure test and charging of refrigerant.
Supply, fabrication and erection of GI ducting with 22 gauge class VIII GI sheet including providing of vanes, MS angle flanges, anchor fasteners, grill collar, tees, bents etc. as per the scope of work enclosed.
Supply and installation of thermal insulation of above ducting with 9 mm thick, closed cell nitryle foam rubber/cross linked polyethylene thermal insulation. The insulation shall covered with aluminium foil of 40G thick and fixed properly by self adhesive aluminium tape as per the scope of work enclosed.
Supply and installation of double deflection type supply air grill / diffuser of following specification. Extruded anodized aluminium, powder coated off white/brown colour, adjustable and locking type aluminium volume control damper having horizontal and vertical louvers. The louver portion shall be removable type for adjusting the voulme control damper as per the specification.
Supply and installation of double deflection type return air grill/diffuser of following specification. Extruded anodized aluminium, powder coated off white/brown colour, adjustable horizontal and vertical louvers and rat entry prevent mesh shall be provided as per the specification.
Installation of a set of hot gas and liquid line copper piping along with thermal insulation and 3 core 2.5 sq. mm, 1100V multi strand felxible FRLS PVC copper cable to inter connect indoor and outdoor units of the above 1.5/2TR/3TR Split air conditioner as per the specification given in the scope of work. It also includes supply of copper tubes, thermal insulation over the copper pipe lines, brass flare nuts at both ends.
Comprehensive maintenance of 20 /40 LPH capacity water cooler. The scope of work includes preventive maintenance, attending servicing/breakdown maintenance, repair and replacement of spares overhauling and cleaning of machine including compressor.
Comprehensive maintenance of 40 /80 LPH capacity water cooler. The scope of work includes preventive maintenance, attending servicing/breakdown maintenance, repair and replacement of spares overhauling and cleaning of machine including compressor.
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 3 TR capacity suitable to Voltas make 3 TR capacity cassette air conditioner.The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R-22/ R410A.
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 1.5 TR capacity suitable to Hitachi split air conditioner (Model No. RAU318HTDG).The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R-22/ R410A. .
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 1.5 TR capacity suitable to Godrej split air conditioner (Model No. GSC 18 BD 3WOT). The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R-22/ R410A.
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 2 TR capacity suitable to Panasonic split air conditioner (Model No. CU-UC24QKY3). The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R-22.
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 1.5 TR capacity suitable to Videocon split air conditioner. The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R-22.
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 8.5 TR capacity suitable to Hitachi make 25TR capacity packaged air condtioner (Model No: CCSO102EUDA3). The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R410A
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 11 TR capacity suitable to Hitachi make 30TR capacity packaged air condtioner (Model No: CCSO132EUDA3). The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R410A
Condenser Coil: Supply, replacement, testing and commissioning of copper condenser coils of 16.5 (3 circuit x 5.5 TR) TR capacity suitable to Hitachi make 35TR capacity packaged air condtioner (Model No: CCSO198EUDA3). The scope of work includes replacement of existing condenser coils, brazing, leak testing, vacuumising and charging of refrigerant R410A
Evaporator Coil: Supply, replacement, testing and commissioning of copper evaporator coils suitalbe to Hitachi make 8.5TR capacity packaged air condtioner. The scope of work includes replacement of existing evaporator coils, brazing, leak testing, vacuumising and charging of refrigerant R-22.
Evaporator Coil: Supply, replacement, testing and commissioning of copper evaporator coils suitalbe to Hitachi make 8.5 TR (2 circuit x 4.25 TR) capacity packaged air condtioner. The scope of work includes replacement of existing evaporator coils, brazing, leak testing, vacuumising and charging of refrigerant R-22.
Dismantling 16.5 TR Package AC units. The scope of work includes safe dismantling, shifting and storing of IDU, ODU, copper tubes with accessories.
Installation, testing and commissioning of 11TR Package AC. The scope of work includes fixing of IDU, ODU, copper tube & electrical cabling between IDU & ODU with necessary accessories, condensate drain, making holes on walls, filling white cement, pressure test and charging of refrigerant.
Installation, testing and commissioning of 16.5 TR Package AC. The scope of work includes fixing of IDU, ODU, copper tube & electrical cabling between IDU & ODU with necessary accessories, condensate drain, making holes on walls, filling white cement, pressure test and charging of refrigerant.
Shifting of 11/16.5 TR Package AC units. The scope of work includes safe shifting and storing of IDU, ODU, copper tubes with accessories. Sufficient manpower, material handling equipments, tools, vehicles shall be provided by contractor as per the technical specification.
RCC Pedestal Work: Supplying, constructing and fixing in position of reinforced cement concrete of 1:2:4 pedestals for supporting of outdoor units at site
TF Air Systems Pvt Ltd (BID ID -3229082)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .