Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹13.0 L+₹1.1 L (9.54%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹13.7 L+₹1.8 L (15.3%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹17.0 L+₹5.1 L (43.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹17.8 L+₹5.9 L (49.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹18.1 L
EMD Value
₹36,260
Closing Date
22 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
84781PROVN OF ADDITIONAL HT BREAKER AND ASSOCIATED ACCESSORIES FOR REGIONAL NETWORK CENTRE FOR PROJ NETWORK FOR SPECTUM UNDER GE NORTH PUNE.
2022_MES_525301_1
84781PROVNOFHTBRKRUGENPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE North Pune
As per Tender
9 documents required · 9 mandatory
₹500
GE North Pune
₹36,260
Yes
11 Aug 2022
20 May 2022
24 Jun 2022
20 May 2022
22 Jun 2022
10 Jun 2022
60 days
Amount
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m depth for laying of UG Cable / Pole /Stays etc getting out in Soft / Loose Soil, complete all as specified and as directed.
Excavating in trenches, not exc. 1.50 m wide and exc. 1.50 m but not exc. 3.00 m in depth, for Foundation of poles / stays, etc. and getting out in soft / loose soil, complete all as specified and as directed.
Removing surplus soil to a distance not exc 50.00 m away and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
Returning, Filling in including spreading,leveling, watering and well ramming in layers not exc. 25 cm thick in soils, complete all as specified and as directed.
M&L for cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as lean concrete in foundation of poles, stay assembly, etc., including formwork (if required), complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation of poles, stays, etc. including formwork (if required) complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate), as in coping of poles, etc. and finishing the concrete surfaces fair and even including necessary formwork required at site(s), complete all as specified and as directed.
Supply & Erecting steel tubular swaged pole type 410-SP-55 (11m long) including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint Internally and externally from bottom end of pole upto PCC coping and applying with two coats of Aluminium painting over a coat of Aluminium primer (externally from top of coping) including writing MES pole No.with synthetic enamel paint (First Grade/quality), complete all as specified and as directed. NOTE : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
M&L cross-arms, bracings, supports, clamps and back plates fabricated from structural steel sections including Nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated / directed and inclusive of one coat of Aluminium primer one under coat and one finishing coat of aluminium paint, complete all as specified and as directed.
S&F Insulator pin type porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11 KV grade, complete all as specified and as directed
S&F expulsion fuse, single pole, channel type / drop out type suitable as per site requirement with working pressure 11 KV grade of capacity 100 Amps, complete all as specified and as directed.
S&F lightening arrestor expulsion type, conforming to IS complete with all fittings, transmission class, discharge capacity 65 kilo amp, 12 KV rated system,and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 4.0 mm dia GI wire, complete all as specified and as directed.
S&F switch air break gang operated for 11 KV grade, triple pole vertically mounted on insulator and fitted on steel frame , current rating 400 amps, mechanically operated mechanism from ground level consisting of operating rod of GI Pipe 25 mm bore (dia) ‘light grade’ of suitable length worked from ground level and with locking arrangement mild steel flat Iron clamp 50 x 6 mm , complete all as specified and as directed
Supply & laying HT XLPE cable insulated screened , PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium conductor , confirming to IS: 7098 (Part-II) 11 KV E Grade ISI marked in drum , cross sectional area 95 Sq mm 3 core, laid in pipes,/ ducts, trenches, under floor, under road crossing including commiissioning and testing complete all as specified and as direcetd.
M&L for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified and as direcetd.
M&L for cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified and as direcetd.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 m deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32 x 6 mm as earthing lead by means of bolts, nuts & checknuts and washers of galvanized iron or steel drawn through GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 m all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with precast RCC cover in CC 1:2:4 type B1 with handle , with G.I 20 mm dia medium grade pipe for watering and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried vertically directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level and top edge of the plate not less than 1.5 mtr below ground level), connected to and including galvanized steel eathing lead wire 4 mm dia by means of bolts nuts check nuts and washers etc GI pipe 15mm dia medium grade for protection of GI strip both to be provided to the extent of 7.5 meters, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/ plinths or fixed on walls oe concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate , including PCC (1:2:4) type B-1 earth pit with MS angle iron frame , cast iron cover with locking arrangement, with GI 200 dia medium grade pipe and MS funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of strata and testing on completion. Note:- GI wire 4.0 mm dia and GI pipe 20 mm bore medium grade for encasing GI wire 4.0 mm dia beyond 7.50 M length per earthing if so required at site shall be measured and paid for seperately under relevant items.
Supply Installation testing commissioning (SITC) , compact, maintenance free, easy to install, reliable , safe and easy to operate 11 KV 3 way motorized ring main unit (RMU) Extensible type suitable for outdoor application without using kiosk comprising load break switches for loop in/ loop out net work and circuit breakers for distribution tarnsformer protection with meter panel complete with all parts necessary for effective and trouble free operation comprising with following
(RMU) KEY COMPONENTS (a) Load break switches and vaccum circuit brakers with independent spring- operated mechanism suitable for motorised operations.(b) RMU Main Tank of 3 mm tthick stainless steel robotically welded with degree of protection IP67 and outer enclosure of CRCA 2 mm thickness (c) Load break switch type tested for mechanical endurance of min 5000 nos of operation ( M2 Class) (d) Circuit breaker suitable for operating duty cycle 0-3 min-CO-3 min-CO (e) RMU with own make of vaccum interrupter and self powered relay (f) 3 Position disconnector/ off load isolator provided in series with vaccum circuit breaker at bus side to enhance making capacity of earthing switch (g) Internal arc rating of the Main Tank of the RMU of AFLR 21 KA for 1 Sec (h) Capacitor voltage dividers serving live-line cable indicators with phase comparison sockets for each function. (j) Two load break isolators for incoming & outgoing cables and one circuit breaker for transformer protection enclosed in the main tank using sf6 gas as insulating medium
BUSBARS Three Nos of continuous Bus bars made up of EC grade copper of rating current 630 Amps & Short time rating current shall be of 26.3 KA for 3 Seconds for 11 KV RMU
ElECTRICAL CHARACTERISTICS : (a) Rated Voltage -11 KV (b) Rated power frequency withstand voltage 38 KV (c) Rated Lighting Impulse withstand voltage - 95 Kv (d) Rated Frequency -50 Hz (e) Rated Current - 630 Amps (f) Short Time with stand current & duration - 26.3 KA for 3 Secs (g) Short circuit breaking current : 21 KA (h) Short circuit breaking capacity : 52.5 KAp
BUSHINGS All bushings at same height, parallel on the equal distance from ground and designed for current carrying capacity 630 Amps. Necessary boots & acess for cable bushings from front and rear with each RMU
CABLE BOXES Cable boxes at each of the circuit breakers shall be suitable for bottom entry of HV cables of size upto 3 C x 400 Sqmm located to the front and rear side of the RMU. Compound filled cable boxes and side cable boxes not acceptable.
METERING (a) RMU shall be provided with seperate metering module consisting of bus connected with Potential Transformer and current transformer . Transformer to be provided for VCB function i.e for Distribution Transformer / Feeder along with Multi function meter.(b) METERING CURRENT TRANSFORMER (i) Type : Ring Type (ii) Material: Cast Resign (iii) Burden : 2.5 VA (iv) Ratio : 100-50/1 Amps (v) Accuracy class for metering : 1.0 Metering LT CTs for breaker shall be provided in side cable compartment with proper supporting arrangement (c) METERING VOLTAGE POTENTIALL TRANSFORMER 3 Nos potential Transformers housed in seperate enclosure for metering purpose (vi) Type : Ring Type (vii) Material: Cast Resign (viii) Burden : 50 VA (xi) Ratio : 11 kV / 3 root /110V/ 3 root For 11 kV (x) Accuracy class for metering : 1.0
Supply and Installation of advance Maintenance free tripod ring earthing system by boring the required nos of holes in semi hard soil or hard soil consisting of 03(three) Nos. UL 467 listed and CPRI tested copper bonded high tensile low carbon steel core electrode rod of 17.2 mm dia with a minimum coating thickness of 250 microns and length of 3 metres tested according IEC 62561-2 with min 10 years life span (the rod should be marked as per the UL certification) Model: AGE-APLI with up and down both side copper plate welded with GI 40mm tube as outer cover of electrod internaly and externaly covered with compound min 3X 25kgs/electrode of earth enhancing compound for each earthing pit (PROCEM) NABL certified, CPRI tested, ecofriendly, tested as per the IEC 62561-7 and needs to be considered to fill the 200 mm bored hole surrounding to the outer/external cover of electrod.In one tripot earthing minimum 09 electrod to be fixed considreded as one earthing. The earth enhancing compound should have resitivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the environment and non corosive to the earth electrode itself including refilling with good earth as specified.
Provision of the connectors for connecting electrode with earthing conductor / strip including fastener made of stainless steel having suitable size according to the electrode and earthing conductor dimensions. All the three earthing electrode would be seperated by appropriate distance and connected to earth other by the incl 32 mm x 6 mm copper strips/copper wire to make ring earth and upto test point terminal and to be burried in appropriate depth not less than 40 cm below normal ground level and earth pit chamber of suitable size not less than 250 x 250 x 250 mm internal dimension made of FRP material complete with flush moundted removable and lockable cover able to withstand 15 KN for each earth electrode all as directed by Engineer-in-Charge.Provision of the connectors for connecting electrode with earthing conductor / strip including fastener made of stainless steel having suitable size according to the electrode and earthing conductor dimensions further connected up to equipment.
The earth result should be less than one ohms other wise payment will not be considered for the work executed under item of earthing. The chamber should have facility for marking earth resistance and latest testing date by paint at the cover including testing and taking out old UNSV earthing pit for credit complete all as specified and directed by Engineer-in-Charge. Make : ASHGEL ELECTRODE/ OB Bettermann /Furse /KLK /Erico / U-Protech all as per the descrition of Engineer-in-Charge.
NOTE: - (a) The rate shall include excavation, earth work, removal of surplus soil, returning filling with back fill compound, etc. (b) Earthing resistance result should be confirming to the value as specified in clause 19.146.14 of SSR Part-I 2009. If the result do not confirm, then the contractor will carry out the earthing in seperate location/site given by the Engineer-in-Charge after taking out of earth electrodes all without any extra cost to the Govt. (c) The contractor will provide all the required and necessary certificate(s) as per the specifications for required item(s) mentioned above from the same company before incorporating the same in the work as directed by Engineer-in-Charge and the rep of Company should be available at the site for the installation of the earthing as per their recommendation and specification to obtain the minimum resistance valve.(d) Test equipment will be duly tested from authorized Govt Lab/CPRI Lab and sealed by the testing authority and produce test certificate of testing equipment before testing for which no extra payment shall be borne by the Govt. (e) Testing of earthing after completion of work will be carried out in presence of the GE, Engineer-in-Charge, rep of user and the Contractor. (f) Contractor will provide the gurantee for earthing and result for the period of minimum 05 years.
NOTE: - (g) Copper strip beyond test point shall be measured and paid separately.Marking Earthing Pit with white/ coloured Hylam sheet/per pex sheet 3 mm thick of size 200 x 150 mm fixed with MS angle iron 20 X 20 X 4 mm and .75 m long lncluding painting with synthetic eneamelled paints 2 coats over a coat of red oxide primer fixed by means of 2 nos nuts,bolts,washer of suitable size and grout the maker nearer to the earth pit with PCC 1:2:4 of size 0.15 x 0.15 x 0.15 m including necessary earth work.Maker shall be written the following letters (letter of size 25 mm)
CHEMICAL TRIPOD EARTHING EARTH PIT NO: EQUIPMENT/BUILDING CONNECTED: DATE OF TEST: EARTH RESISTENCE IN OHMS :Name plate white / coloured hylam sheet / perpex of 3mm thick of size 150 x100 mm and fixer to the equipment/building or nearest to the equipment on the wall by screwing and name plate shall be written the following letters (letters of size 25 mm) CHEMICAL TRIPOD EARTHING EARTH PIT NO: EQUIPMENT/BUILDING CONNECTED: DATE OF TEST: EARTH RESISTENCE IN OHMS :
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm copper strip complete all as specified and as directed.
All as per item No 21 here- in- above but 20x3 mm copper strip
M&L test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw
Techmat trading solution
SBS Enterprises
CHAITANYA WINDWELL
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
Takshashila electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .