Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹26.8 L+₹5,777 (0.22%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹27.3 L+₹56,297 (2.11%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹27.9 L+₹1.2 L (4.46%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹28.5 L+₹1.7 L (6.48%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
12 Aug 2022, 6:00 pmClosed
GE NW BHANDUP
GE(NW) BHANDUP, MUMBAI
REPAIR/REPLACEMENT TO ROOF SHEET, VELLY GUTTER, RAIN WATER PIPE, WATER PROOFING TREATMENT, LEAKAGE SEEPAGE AREA, PLASTER, PARAPET CHAJJAS ETC, REPAIR/REPLACEMENT TO JOINERY SANITATION AREA, ROLLING SHUTTERS AND OTHER CONNECTED MISC ITMS INCLUDING PER
2022_MES_532341_2
8204/B
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹86,000
Yes
7 Oct 2022
21 Jul 2022
13 Aug 2022
21 Jul 2022
12 Aug 2022
5 Aug 2022
Amount
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shocs, bends etc complete all as specified and directed.
M&L for 6mm thick asbestos cement corrugated or semi-corrugated sheet fixed with l-type or j-type or cranked hook bolts in roof,walls etc. complete all as specified and directed.
All as per item No.03 above but except sheets complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F 2 mm fibre glass reinforced translucent corrugated sheeting of a similar pattern as that of PPGI sheet with two corrugations side lap fixed with coach screw, GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
Dismantling wrought iron or milt steel work of vallay gutter and expended metal any description not other wise provided for complete all as specified and directed..
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
S&F 1mm thick GI sheeting in ridges hips, valley gutters, drip etc necessary dismantling of AC sheets and refixing the same position and complete all as specified and directed.
M&L for removal of loose and disintegrated concrete of RCC structural members viz slab, beam, column and lintel etc by low impact hammer including removal of debris outside MD land. Cleaning of exposed reinforcement bars with wire brush and apply two coats of anti-rust protective chemical at suitable intervals all as per manufacturer's instructions to resist further deteoration of reinforcement bars. Apply approved epoxy based bonding coat on concrete surfaces to achieve sound bond between existing and new concrete. M&L for profilling of structural members with polymer modified mortar 1:3 mixed with and including 15% latex polymer by weight of cement (w/c ratio 0.35) including leveling to match the surface. Application of complete treatment shall be through approved applicator all as per manufacturers instructions (Bauchemic Krishna or Sunanda) including scaffolding for following 20mm average thickness of polymer modified mortar complete all as specified and directed
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M & L for removing loose, disturbed or disintegrated old concrete surfaces of RCC beam, column, lintel, pardi, railing etc, cleaning throughly exposed reinforcement, preparing exposed concrete surfaces to receive guniting, applying anti corrosive paint to the exposed reinforcement, supply and fix welded wire mesh of size 100 x 100 mm of 3 mm dia wire, weight not less than 1.37 Kg/Sqm & binding with 22 gage binding wire to reinforcement and applying pressure guniting in cement mortar 1:3, minimum thickness 30 mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound 2% by weight of cement and finishing the surface even and smooth without using extra cement to match the existing surfaces, removing the debris outside MD land including material and labour for necessary scaffolding and safety arrangement for guniting work complete all as specified and directed (Note :- The finished of the surfaces to be matched with the existing surface. WPC Shall be measured & paid separately)
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L 15mm thick cement plaster in two coats using factory manufactured pre mix/ready mix having minimum composition of cement and sand 1:4 using fully treated dry well graded natural sand confirming to ISI 383 suitable for external plastering having low rebound properties low water demand for curing properties, mechanical mixing with water in a metallic tray only to make a good consistency as per the specification of the Manufacture and apply over exterior masonry and concrete surfaces with base coat of 10mm thick and finishing coat of 05 mm thick final rendering including cleaning the surfaces curring etc. complete all as per specified and directed. Note: Work shall be executed at multiple places as per required and at any height upto five store bldg.
Supply only integral water proofing compound complete all as specified and directed.
Material and labour for cracks with polymer based chemical Dr fixit cracks shrink free or equivalant for cracks not exc 10mm in width as per manufacturer instruction on wall surfaces on concrete or masonry incl scaffolding etc complete all as spd.
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty (3mm thick) for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of ceiling and applying two coats of OBD incl one coat of primer complete all as specified and directed
M&L for preparation of old decorated surfaces and applying one coat of white wash on wall, coloums, beams etc complete all as specified and directed..
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounding, glazed with putty or fixed with beads complete all as specified and directed.
M&L for 4.0mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
S &F, in repairs, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 300x300 mmx 7mm thick in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% weather resistant antifungal exterior acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for preparation of old acrylic surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying one coat of 100% weather resistant antifungal exterior acrylic paint of approved shade including necessary scaffolding work etc complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
S&F aluminium section in doors/kitchen cuboards ,any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing bakelite sheet and all necessary fittings complete, screws,plugs, locking arrangements for cuboard, Nylon ball bearing ,hinges,handle,tower bolt, etc all as specified and directed Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet will be measured separately.
S&F only 4.80mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator n exc 0.50 Sqm each pane all as specified & as directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : Minimum thickness of anodizing shall be 15 microns.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S & F Steel rolling shutter ( thickness of lath 1.25mm thick) without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, and including taking down of any thickness etc, complete gear operated type with bevel gear box and crank handle etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contract of wwod work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and disposing off the rubbish outside MD land complete all as specified and directed.
M&L PCC 1:3:6 C-2 (using 20mm graded crushed stone aggregate) as in plinth protection, sub base of floor ( 75mm thick ) finished even and fair all as specified.
S&F PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & taking down old trap complete all as specified and as directed.
S&F PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including taking down old trap complete all as specified and as directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
Routine maitenance of rolling shutter of following sizes the maintenance including the following all as specified and directed. (a) Taking down hood covers for carrying out routine maintenance and refixing. (b) Dismantling the MS and CI works of any description such as sheets, shafts, cost iron wheels lath etc and taking down helical springs, rollers and other accessories etc. (c) Refixing the unserviceable accessories such as shafts, helical springs, rollers lath sheets, cast iron wheels etc. (d) Replacement of the unserviceable accessories such as shaft helical spring, rollers, MS lsth sheets hood covers, cast iron wheels including drilling, welding etc complete. (e) Cleaning, oiling, greasing etc complete of all movable parts all as required at site( Note- The parts and accessories to be replaced shall be measured and paid seperetely ) (A) Area of shutter n.exc 5.00 sqm maximum size 1.80mx2.40m
All as per item No.62 above but Area of shutter exc 5.00 sqm but n.exc 10.00 sqm (maximum size 3.20m in height) complete all as specified and directed.
All as per item No.62 above but Area of shutter exc 10.00 sqm but n.exc 20.00 sqm (maximum size 5.15m in height) complete all as specified and directed.
All as per item No.62 above but Area of shutter exc 20.00 sqm but n.exc 40.00 sqm (maximum size 6.77m) complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coat of aluminium paint over a coat of red oxide etc complete all as specified and directed.
M&L for preparation of old steel surfaces and applying one coat of aluminium paint etc complete all as specified and directed.
Routine maitenance of sliding door shutter of following sizes the maintenance including the following all as specified and directed. (a) Dismantling of MS works of any description such as rollers pulleys, guides, bottom sliding tracks and corrugated sheets including necessary straightening of bends. (b) Refixing the serviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (c) Replacement of unserviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (d) Cleaning, oiling, greasing etc complete of all movable parts all as required at site( Note- The parts and accessories to be replaced shall be measured and paid seperetely ) (A) Area of shutter n.exc 5.00 sqm of each leaf
All as per item No.68 above but Area of shutter exc 5.00 sqm but n. exc 10.00 sqm of each leaf complete all as specified and directed.
All as per item No.68 above but Area of shutter exc 10.00 sqm but n. exc 20.00 sqm of each leaf complete all as specified and directed.
M&L FOR SUPPLY and APPLICATION OF 7 LAYER SHR WATERPROOFING COATING SYSTEM ON LEAKING CONCRETE SURFACES BY THOROUGH SURFACE PREPARATION, OPENING OF CRACKS FOLLOWED BY ONE ABSORPTION COAT OF THERMACOOL WP51, NANO TECH MODIFIED, UV RESISTANT ELECTROPLAST CLEAR COAT HAVING MIN 50% SOLIDS, FILLING OF CRACK, THEN OVERCOATING WITH SANDWITCH COAT OF ELECTROMERIC (THERMACOOL WP51 + CEMENT) WATERPROOFING LAYER WEIGH 80 GSM NON WOVEN FIBRE MESH, APPLICATION OF 3 RD COAT OF ELASTOMERIC WATERPROOFING LAYER HAVING +450% ELOGATION, TENSILE STRENGTH MIN 2.2 MPA AND THEN TOP-COATED WITH TWO CATS OF THERMACOOL 0.3C PURE ACRYLIC BASED, UV RESISTANT NON-YELLOWING BIO-ORGANISM RESISTANT (ANTIFINGAL, ANTIBACTERIA) SOLAR IR HEAT REFLECTIVE COATING CONFIRMING TO BIS STD IS 17218:2019 WITH PULL OFF ADHESION 2.8 MPA PASSES 2000 HRS ACCELERATED DURABLITY TEST SUITABLE FOR ALL TYPES OF CEMENTITIOUS SURFACES WHITE COLOUR MATT SURFACES COVERAGE 3.25 SQM /LTR/2 COAT DFT 100-120 MOCRON USING BRUSH ROLLER AIRLESS SPRAY GUN AS APPLICABLE SND APPLICATION IS TO BE DONE BY COMPANY APPROVED APPLICATOR ONLY" complete all as specified and directed. Make Thermacool or equivalant
Taking down carefully copper/aluminum point wiring of any type such as concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including stove enamelled steel conduit ISI marked not less than 20/25 mm dia surface on wall,ceiling with GI saddles, GI screws rawl plug (surface conduit wiring) with all fittings including tee,junction boxes PVC connector and provision of modular pressed steel terminal box of suitable size with inner and outer plates of mounting switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 73 above but one 5 Amps switch socket on same board all as specified and directed.
All as per item No 73 above but one 5 Amps switch socket on indipendent board all as specified and directed.
All as per item No 73 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including non metallic PVC casing caping ISI marked not less than 20/25 mm dia surface on wall,ceiling with all fittings including tee,junction boxes PVC connector and provision of Modular steel terminal box of suitable size with inner and outer platesmounting of switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 77 above but one 5 Amps switch socket combination on independent board all as specified and directed.
All as per item No 77 above but one 5 Amps switch socket combination on same board all as specified and directed.
All as per item No 77 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on rigid PVC conduit and conduit accessories of 20/25 mm complete with modular steel terminal box concealed in wall with inner and outer plates for fitting/ mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one15 Amp socket point for connecting water coolers/ AC.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs switch modular type 16 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan modular regulator stepped type 120 watts AC 230 V 2 module type complete all as specified and directed.
Supply and fix in repairs ceiling rose surface backelite three terminal complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply & Fixing LED Light fitting 18 watt 220 V AC Decorative Box type with driver holder including ted complete with housing and LED 18 watt with aluminium heat sink on back of led rod,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed.
Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 120W , power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete painting with two coats synthetic enamel paint over a coat of red oxide complete dismantling existing unserviceable high bay fittings all as specified and directed.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs 100 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting dismantling existing unserviceable 2x40 watts Flu. tube light fitting complete.
Supply and fixing highly efficient high power multi LED flood light fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: CG/Luker/Havells/Shakti Note1.Guarantee period of complete fixture should be minimum 3 years from the date of completion
M&L for submain wiring in and including Steel conduit having thickness 1.8 mm, 20 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Material and labour for rewinding of stator assembly of exhaust fan/bracket fans/wall mounting fans/pedestal fans 375 to 450mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in positionetc complete all as specified and directed.
Material and labour for rewinding of stator assembly of exhaust fan 600mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in positionetc complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder coated MCCB DB TPN vertical type double door suitable for TP/FP G frame MCCB as incomer 415 V 8 way with 200 Amps rated bus bar din rail neutral link all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 6 Amp to 32 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix in repairs MCB SPN 240 Volts 40 Amp to 63 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps B Curve breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 40 to 63 Amps B Curve breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCCB 415 volts 16 KA FP 100 Amps complete all as specified.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor .
Deduct Credit for Demolished/ Dismantled material Rs. (-) 93092.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
S K ENTERPRISES
R J ENTERPRISES
M/s Qureshi Construction Co
SB CONSTRUCTION
BREEZE CONSTRUCTION
M/S VISHRANTA CONSTRUCTION
Chaudhary Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .