Shifting of HT LT Lines and Transformer at Parvati nagar in ward no 35 hospete limit. 2 Shifting of 100 KVA R51 Transformer at Parvati nagar in ward no 35 hospete limit.
DMA/2023-24/EL/WORK_INDENT3196
DMA/2023-24/EL/WORK_INDENT3196
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Municipal Council Hosapete
5 documents required · 5 mandatory
₹500
₹16,250
29 Aug 2023
29 Aug 2023
11 Sept 2023
1 Shifting of HT LT Lines and Transformer at Parvati nagar in ward no 35 hospete limit. 2 Shifting of 100 KVA R51 Transformer at Parvati nagar in ward no 35 hospete limit.
278811-11kv danger boad
278911-barbed wire 10 mts
2798001-fish plate with necessary clam
281800-8-SWG G.I wire
281110-7 410-SWG guy wire
281101-Guy with complete set
2811103-Earthing materials tyoe for gr
283008-11kv 5KN composite/polymeric
283320-selicon rubber composite insula
284503-Lt spacer for TC wiring
285557-120sqm mm P.G clamps rabbit
288532-120 sq. mm copper termianals
303200-L A 9kv metal oxide
b wiring of two circutes of LT wiring kit for 25/63/100 KVA DTC ti the xisiting LT protection Kit/distrubustion box via metering box
11KVA dead end insulator Disc, starin etc
11KV pin insulator
b Erection of 100 KVA transformaer on transformer structue
b realseing of 100 KVA transformaer on transformer structue
Erection of RCC/PSC poles 9 to 10 metering but in pit 1.8 depth
erection of same
Fixing of DOLO cutouts/horn gap fuses including fixing cross arms and wiring
Fixing of GOS including wing 11kva sB 200A
Fixing of LT protection kit
Fixing of HT fuse units & wiring
Releasing & restrining tightening of loose spans a weasel squirrel
Relesing and fixing of energy mtrs
releasing of 11 kv pin insulator
Releasing of H Frame
Relesing of providng spiral earth electiode type earting along with pole without charcoal salt etc
Fixing danger board
GI barded wire 12 mtrs 1kg
wiring of two circutes of LT wiring kit for 25 63 100 KVA DTC ti the xisiting LT protection Kit distrubustion box via metering box
fixing of GUY set with break insulators making use of 7 3 15mm 7 10SWG galavanised steel wire wioth turn buckle and anchoring arrangement as per approved drawing excluding excavation of PIT
Providng GI pipe earthing for lightning arrestes transformer metal part excluding digging of pits
Fixing of nos fighting arrestires including wirirng
1 Shifting of HT LT Lines and Transformer at Parvati nagar in ward no 35 hospete limit. 2 Shifting of 100 KVA R51 Transformer at Parvati nagar in ward no 35 hospete limit.
278911-barbed wire(10mts)
281008-8 SWG GI wire
281110-7/10 SWM Guy wire
2811101-Guy with complete set
2811103-Earthing materials type fro gr
284108-Rabbit ACSR conductor
284792-114kv3x120+1x95(bare (insul
284825-Dead end clamp/anchor clamp
284826-Suspension clamp assembly 25t
2788-11-11kv danger board
278911-barbed wire(10 mit)
27911104-9 mtr RCC DP transformer strct
2798001-Fish with necessary clam
281008-8 SWG GI wire
281110-7/10 SWg guy wire
2811-01- gus with complete set
2811103-Earthing materials type fro gr
283008-11kv 5KN composite plymeric
283320-silicon rubber composite insulate
284503-LT spcaer for TC wiring
285557-120sqmm (pg clamps rabbit
2885332-120sqmm compper terminals(lo)
301107- LT ptotection kit
301230-L T distrubustion box 100
300-11-11kv DOLO cutouts convert
200105-RCC Pole -9.0 mlong 145 kg WL
2811101-guy with complete set
281683-spiral easrth electrode
284108-Rabbit earth conductor
284819-3x95+1x70+1x16 street light
284833-end cap for 50/70 sqmm
284838-suspention clapmp assembly 16
284842- dead end clamp/anchor clamp
284845-Ehe hook (flat type) for fixin
791101-ACSR conductor scrap
793509-released scrap iron pole kg
wiring of ne circute of LT wiring kit for 25/63/100 KVA DT to th existing LT protection kit/distrubustion box via metering box
a Erection of 25-63 KVA transformer on transformer structure
b erection of 100 kva transormer on transformer structer
b erection of 100 kva transormer on transformer structer
b erection of 100 kva transormer on transformer structer
Fixing DOLO /horns gap fust including fixing cross arms and wiring
Fixing of distrubution box 100/250/500 KVA DTC inlcuding wiring
Fixing of 3 nos lighting arresters inluding wiring
Fixing of GOS including wiring 11kv SB 200A
Realesing of fixing DOLO cutouts/horm gap fused including fixing of cross arms and wiring
Relsing of fixing LT distrubution box for 100/250/500 KVA Dts(excuding wiring)
releasing of fixing of 3 nos lighitng arrestrors inlcuding wiring
GI barbed wire12 mtrs/1kg
a) fixing of GUY sets with break insulators making use of 7/3.15mm (7/10 SWG) galvanised steel anchoring arrenegement as per approved drawing (excluding exavation of PIT)
providing GI pipe earting fro lightning arresets transformer metal parts exluding diging of pits
For rabbit ACSR
erection of anchodre clamp-25 to 95 sq mm bare messenger
Erection of supension clamp-25-95 sqmm insulated messenger with bracket
Fixing danger board
GI barbed wire12 mtrs/kg
Erection of pole 100 to 250 kVA with 9 mtrs RCC pole
a wiring of ne circute of LT wiring kit for 25/63/100 KVA DT to th existing LT protection kit/distrubustion box via metering box
a fixing of guy sets with break insulators making use of 7/3.15mm 7/10 SWG galvanised steel anchoring arrenegement as per approved drawing excluding exavation of PIT
providing GI pipe earting fro lightning arresets transformer metal parts exluding diging of pits
fixing of LT protection kit
Fixing LT distrubution box for 100/250KVA DTCs excluding wiring
Fixing DOLO /horns gap fust including fixing cross arms and wiring
Erection of RCC/PSC poles 9 to 10 mtr long but In a pit of 1.8 metrs depth
a) fixing of GUY sets with break insulators making use of 7/3.15mm 7/10 SWG galvanised steel anchoring arrenegement as per approved drawing excluding exavation of PIT
providing spiral earth electrode type earthig along woth pole without charcoal salts ets
For rabbit ACSR
Stringng pf 1.1KV grade arrial bunched 3 core cable of XLPE insulation standerd aluminium conductor standerd around a weather resistance black XLP wire1 3x95 for phase conductor+1x70 insulated messeng...
Enad cap fro 50/70 sqmm
erection of suspention clamp-25 95 sqmm bare messeneger
erection of suspention clamp-25 95 sqmm bare messeneger
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bid document.doc
Tender Document • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .