| 1 | L1₹54.9 LAccepted-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹61.4 L+₹4.8 L (8.46%)Rejected-Finance HOUSE NO 5 WARD NO 8 UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹67.5 L+₹10.9 L (19.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹68.2 L+₹11.6 L (20.5%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹70.4 L+₹13.8 L (24.4%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
21 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/ REPLACEMENT OF CERTAIN B/R AND E/M ITEMS ALONGWITH WITH CONNECTED ITEMS AT JNE CELL AND ADJOINING AREA UNDER GE (NORTH) UDHAMPUR
2024_MES_639196_1
CWE/U(N)-36/2023-24
Open Tender
Civil Works
Item Rate
270 days
Udhampur
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (NORTH) UDHAMPUR
₹1.3 L
14 Jun 2024
25 Jan 2024
28 Feb 2024
25 Jan 2024
21 Feb 2024
16 Feb 2024
27 Jan 2024 - 10 Feb 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed.
Vitrified tiles (double charged) tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in coloured cement to match the light shade of tiles and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed.
Glazed coloured ceramic jointfree / rectified tiles 450x300mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed.
Machine cut kota stone slab flooring 18-20mm thick over and incl screed bed or bedding layer 20mm thick in cement mortar 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in floor including rubbing and polishing mirror finish complete, all as specified and as directed.
Machine cut kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 15 mm thick rendering in cement mortar 1:4 as in backing coat for laying wall tiles, complete all as specified and as directed.
Granite(of any type) stone slab 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding to edges of stone slabs one edge in shelves/ verticle surface / platform, complete over and including 20mm thick backing coat/ bedding in CM 1:4 complete all as specified and as directed.
Rounding of/moulding to edge (half round) of stone of any description, such as in steps, cooking platform and other similar situations including rubbing and polishing (Granite finish), complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed.
15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
10mm thick rendering on brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete, all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed.
Description all as per item No. 14 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Taking down shutters of any descriptions area exceeding 1 square metre and not exceeding 2 square metre each complete, all as specified and directed.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed.
Description all as per item No 17 above but frame size 105 x 60 mm.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
Description all as per item 19 above but glazed and skeleton shutter with sash bar for glass/wire gauge.
30 mm thick flush shutters, solid core construction, with block board core and ply wood face pannels, commerical type on both sides and one face is covered with decorative face veneer with lipping / frame to match polished on back side and sides of shutters complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregates) for filling in the pressed steel door frame/hold fast complete all as specified and as directed.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed (ISI Marked).
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), coloured (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed.
Water closet (Squatt pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision including 32mm dia PVC flush pipe, fixed in repairs, complete all as specified and as directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed.
Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia, fixed in repairs, complete all as specified and as directed.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixed in repair, complete all as specified and as directed.
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs, fixed in repairs, complete all as specified. (ISI Mark)
Preparation of surfaces by complete removal of existing treatment from old decorated plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty on walls to give uniform surface, complete all as specified & directed.
Preparation of surfaces by complete removal of existing treatment from new decorated plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty on walls to give uniform surface, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed.
Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed.
Preparation of old decorated plastered or unplastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying one coat of white wash on walls, complete all as specified and as directed.
Description all as per item No. 43 above but on ceiling.
Washing, rubbing down and stopping of old distempered surfaces including preparation and applying one coat of distemper oil emulsion to walls, complete all as specified and as directed.
Preparation of old wooden surfaces exceeding 10 cms width or girth and applying one coats of synthetic enamel paint, complete all as specified.
Preparation of old steel and iron surfaces exceeding 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
Refixing old steel water tubing medium grade galvanised and connections in new or old position (walls, ceiling, floor etc.), 15 mm bore, complete all as specified
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
25mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
Stop valves, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed.
Bib taps, fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed.
Waste coupling of PTMT for 32mm dia discharge pipe (half or full threaded) (Minimum weight 32mm 45gms/ 40mm-60 gms), fixed in repairs, complete all as specified and as directed.
PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
Rotational moulded polyethylene water storage tank, two layers, inner and outer white, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories {i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc}, incl dismantling existing water tank, complete all as specified and as directed.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), including dismantling existing water tanks, complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for including and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor/paving, complete all as specified and as directed.
40mm thick flooring in PCC 1:2:4 , type B-1 (using 20mm graded crushed stone aggregates) surfaces finished even and smooth with using extra cement (staircase incl steps), complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment, over and including 25mm thick layer of sand cushioning, complete all as specified directed.
Chequered cement concrete tiles 20cm x 20cm x 25mm thick, with mixture of white & grey cement in equal proportion & no pigment set, jointed and pointed in neat cement slurry in floors, including and over 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
Aluminium (Die cast) body door closer hydraulically regulated, designation No. 1, universal type, suitable for door shutters of 700 mm in width and of weight between 35 kg complete all as specified and as directed.
Viterous china wash basin, white flat back size 580 x 450mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete all as specified and as directed.
Towel ring brass chromium plated fixed with and chromium plated brass screw in wooden/plastic cleat, fixed in repairs, complete alll as specified and as directed.
Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe), fixed in repair, complete all as specified and as directed.
Demolition of Cement Concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified.
RCC 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.
Reinforced cement concrete 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete, all as specified. (ISI Mark)
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete without glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, glazing pins/aluminium beading, etc. including powder coating of thickness minimum 50 micron, complete all as specified and as directed.
Powder coated (of approved colour) aluminium (minimum thickness or powder coating not less than 50 micron). window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete, all as specified and directed.
Powder coated aluminium grill of 5 to 6 mm dia size of mesh not exc 7.5 cm in either direction (deco grill - 104) including aluminium channel, complete, all as specified and directed
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part made of mild steel heavy duly and fixed repair including taking down aluminium shutter and refixing in replacement of pivat complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed.
4mm thick Cement fibre board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm 605mm including all accessories, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge. Make of false ceiling board & GI Grid : Everest/V board or equivalent as specified in PS
4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber /GI/Aluminium framework with screws, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridges, all as directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
110mm PVC (SWR) pipes single/Double socketed of any length with rubber ring joints, fixed to wall incl clamp etc, complete all as specified and as directed.
75mm PVC (SWR) pipes single/Double socketed of any length with rubber ring joints, fixed to wall incl clamp etc, complete all as specified and as directed.
Dismantling of boarding any discription fixing in any position with nail complete all as specified and as directed.
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as specified and as directed.
BLANK
Providing and laying water proofing treatment to sunken portion of WCs, bathrooms, etc by applying first layer of slurry of cement @ 0.488kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253kg/sqm this layer allowed to air cure for 4 hrs then applying slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg/sqm and allowed to aircure for 4 hrs and joints seal with sealing compound as approved by GE. Note: (i) Before laying of lime concrete joints of trap/WC/Soil pipes shall be properly sealed with sealing compound of Roofex/Forre/FOSROC and provn of P or S trap & Nahani /Floor traps with long arm complete all as specified and directed.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
Lean concrete 1:5:10 type E-2 using 40mm graded brick aggregates as in sunken floor/ foundatiom, complete all as specified and as directed.
Demolition of un-reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, including separation of serviceable materials from the unserviceable; stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3.00 kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Hand shower (health faucet) brass CP with 8mm dia 1 meter long flexible tube with wall hook, complete all as specified and as directed.
Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection; for EWC fixed complete all as specified and as directed.
Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, fixed in repair complete all as specified and as directed.
32mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, including removing old trap to store, fixed in repairs, complete all as specified and directed.
Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed.
Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, fixed in repair complete all as specified and directed.
Sink wall mixer, brass, chromium plated, fancy type, with capstan head handles screwed down high pressure, with lettered 'hot' and 'cold', including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, fixed in repair, complete all as specified and directed.
Sinks with draining board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
18/19mm thick Prelaminated particle board, medium density flat pressed single layer tyoee or three layer type with BWR, type BB, adhensive, complete all as specified and as directed.
Continuous (piano) hinges width of flaps 30 mm when opened, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
Hasp and staple, 100 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, all as specified .
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed.
Taking down MCB DB any type/size etc. after disconnecting (servicable DBs/MCBs shall be reused), complete all as specified and directed.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer cover plates for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, fixed in repair, complete all as specified & directed. Note: Modular metal flush boxes & inner and cover plates deemed to be included in quoted rate.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for ceiling fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer cover plates for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, fixed in repair, complete all as specified & directed. Note: Modular metal flush boxes & inner and cover plates deemed to be included in quoted rate.
Description all as per item No 122 above but for bell/ buzzer on independent board controlled by one push button bell switch.
Description all as per item No 122 above but for 3/5 pin 6 Amp socket outlet on the same board with other switch.
Description all as per item No 122 above but for 3/5 pin 6 Amp socket outlet on independent board .
All as per description of Serial item No 122 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly.
Description all as per item No 122 above but for one light point controlled by 2-two way switches.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed casing and caping medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed
All as per description of Serial item No 129 here-in-before but One light point controlled by two 2 - way switches.
Description all as per item No 129 above but for 3/5 pin 6 Amp socket outlet on the same board with other switch.
Description all as per item No 129 above but for 3/5 pin 6 Amp socket outlet on independent board .
All as per description of Serial item No 129 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly.
Description all as per item No 129 above but for bell/ buzzer on independent board controlled by one push button bell switch.
Switch piano, single pole, one way, 6 Amp (flush type), 240V, 50 Hz AC, complete all as specified and as directed.
Switch piano, single pole, two way, 6/16 Amp (flush type), 240V, 50 Hz AC, complete all as specified and as directed.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type , complete all as specified and as directed.
Switch piano , single pole, one way ,16 Amp (modular type) , complete all as specified and as directed
Switch socket outlet, 2 in 1, 3/5 pin, 10 Amp and 20 Amp flush type , complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed.
Bell (ding dong type), AC electronic type, 230 volts, single pole, 50 Hz complete all as specified and as directed.
Switch piano flush type for bell push 5 Amps 230 volts complete all as specified.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as directed.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit/PVC casing & caping 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including taking down old sub main wire, complete all as specified and directed Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit/PVC casing & caping 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including taking down old sub main wire, complete all as specified and directed Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 1.5 Sqmm ( 2x1.5 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit/PVC casing & caping 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 1.5Sqmm (1x1.5sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including taking down old sub main wire, complete all as specified and directed Note:- 2 runs of 1.5 Sqmm (2x1.5sqmm ) ,one run of 1.5 Sqmm (1x1.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 2.5 Sqmm ( 2x2.5 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit/PVC casing & caping 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x2.5sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire including taking down old sub main wire, complete all as specified and directed. Note:- 2 runs of 2.5Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Fixing only serviceavle MCB DB any type and capacity as obtained against item No. 121, complete all as specified and as directed.
Refixing Led tube light fittings of 5w/12w/20w/2'x2' panel light bulk head fitting 9W as obtained from taking down, complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 4 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed.
Sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 4 ways, vertical type, including 125 Amps MCCB, 16 kA, 415 volts with 400 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, complete all as specified and directed. (Including all PCC & cementing work for installation of TPN DB to wall).
MCCB 4 pole, 415 volts 63 Amps with breaking capacity 16 KA including making necessary arrangement, complete all as specified and as directed.
MCCB 4 pole, 415 volts 100 Amps with breaking capacity 16 KA including making necessary arrangement, complete all as specified and as directed.
MCCB 4 pole, 415 volts 125/160 Amps with breaking capacity 16 KA including making necessary arrangement, complete all as specified and as directed.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note: Make of MCB and DB shall of same make for all connected items.
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5 Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repairs complete all as specified and directed. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, fixed in repairs complete all as specified and as directed.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repairs, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
9/10 watt LED Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED (Make of LED shall be CREE/Nichia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting, fixed in repairs complete all as per the directions.
LED luminaire 600 mm x 600 mm, 35/36 watt , 220 V AC recess mounted type with high efficiency PC diffuser Each soft glare free light and symmetrical illumination complete with driver holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size, fixed in repairs complete all as specified and directed.
LED Garnet 18W Batten PLL Lamp, 4 pin type, 6500K as per sampler fixed in repairs, complete all as specified and as directed.
MCB TPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repairs complete all as specified and as directed.
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with and including one single pole MCB of 20 Amps and breaking capacity 10KA, fixed in repairs complete all as specified and as directed.
Switch piano, single pole, two way, 5 Amp (flush type), 230V, 50 Hz AC, fixed in repairs complete all as specified and as directed.
Switch piano, single pole, one way, 5 Amp (flush type), 230V, 50 Hz AC, fixed in repairs complete all as specified and as directed.
Switch piano flush type for bell push 5 Amps 230 volts, fixed in repairs complete all as specified.
Switch socket , 2 in 1, 3/5 pin, 5/6 Amp flush type, 240V, 50 Hz AC, fixed in repairs complete all as specified.
Switch socket, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, 240V, 50 Hz AC, fixed in repairs complete all as specified.
Switch piano, single pole, one way, 16/20 Amp (flush type), 230V, 50 Hz AC, fixed in repairs complete all as specified and as directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, 240V, 50 Hz AC, fixed in repairs complete all as specified.
Switch socket combination, 2 in 1, 3/6 pin, 5/6 & 15/16 Amp flush type, 240V, 50 Hz AC, fixed in repairs complete all as specified.
Switch socket combination box type, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed.
Switch socket combination box type, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, fixed in repairs complete all as specified and as directed.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically, fixed in repairs complete all as specified and as directed.
Bell (ding dong type), AC electronic type, 230 volts, single pole, 50 Hz, fixed in repairs complete all as specified.
Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 %, including taking down unservicable complete all as specified and as directed.
Modular switch single pole one way 6 Amps 1 module, fixed in repairs complete all as specified and directed.
Modular switch single pole one way 16 Amps 1 module, fixed in repairs complete all as specified and directed.
Bell push Modular type, 1 module, 6 Amps 230 volts, fixed in repairs complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined 2 module, fixed in repairs complete all as specified and as directed.
Modular socket, 6/16Amps, 2/3 pin combined 2 module, fixed in repairs complete all as specified and as directed.
PVC rectangular block for mounting switches, sockets, fan regulator etc. 200x150x50mm deep including making necessary cutting, complete all as specified and as directed.
PVC rectangular block for mounting switches, sockets, fan regulator etc. 250x200x50mm deep including making necessary cutting, complete all as specified and as directed.
3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting/ finishing or making hole for mounting of switches, sockets, regulators etc., complete all as specified and as directed.
3 mm thick plastic laminated ebonite sheet cover of size 250x150mm including cutting/ finishing or making hole for mounting of switches, sockets, regulators etc., complete all as specified and as directed.
Disconnecting all electrical connection from MCB DB TPN/ Wall Mounted Panel Box for reconnecting the same with providing proper copper bottle lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire, complete all as specified and directed by the Engr-in-Charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items.
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase, complete all as specified and directed by the Engr-in-Charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
Cutting of hard standing not exceeding 45 Cm defth, and not exceeding 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing, complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 195 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Energy saving LED garden light fitting decorative , bollard type of capacity 9/11 watt with opal diffuser, Aluminum reflector complete with all accessaries and fixing arrangement on PCC block of size 45mm X 45 mm alogwith fixing nuts , bolts and PVC insulated aluminum conductor stranded type of size 4.0 sqmm 2- core including taking down old unservicebe garden light fittings any type and wattage, fixed in repairs complete all as specified and as directed
New generation energy saving and environmental friendly long life LED street light of 25/35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe any size bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as specified.
Decorative LED gate light fitting of 30/40 watt , 240 volts diecast aluminum housing in pure polyster powder coated gray finish top maintainable product with opening die cast cover , anti corrossive stainless steel screws & silicon gasket HET PMMA diffuser IP65 protection driver duly prewired up to terminal on firms to IS 10322 part 5 / sec, 1:1987 suitable for pole of dia 65-75 mm in - built electronic driver complete including taking down old / unserviceable gate light fitting, fixed in repirs complete all as specified and as directed.
M/s Rukmani Construction Company
M/S VINAY KUMAR SHARMA
K S BUILDERS
LUXMI ELECTRONIC WORKS
JINDAL BUILDERS
joginder singh and sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .