Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 CrAccepted-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹8.1 Cr | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹9.7 CrRejected-Finance | ₹9.7 Cr | L2 | Rejected-Finance L2 Bidder |
| 3 | Rejected-Technical ALAKPURI NEAR DURGA MANDIR DIST GIRIDIH | GIRIDIH | JHARKHAND | 815301 | - | - | Rejected-Technical Technically Non - Responsive |
| Sl No | Description | Qty | Unit | M/s Raj Construction L1 | JUNAID ENTERPRIES L2 |
|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 2,410.65 | SQM | 16.98 ₹40,932.84 | 18 ₹43,391.70 |
| 2.00 | Cutting of trees, excluding removal of stumps and roots of trees | 20 | nos | 566.11 ₹11,322.20 | 1,500 ₹30,000 |
| 3.00 | Removal of stumps and roots including backfillinbg with suitable material to required compaction | 20 | nos | 339.66 ₹6,793.20 | 1,000 ₹20,000 |
| 4.00 | Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 1,100 | litre | 217.38 ₹2.4 L | 235 ₹2.6 L |
| 5.00 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the
vertical surface of the substructure to a depth of 300mm including excavation channel along the wall
& rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration | 1,100 | m | 36.23 ₹39,853 | 40 ₹44,000 |
| 6.00 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart
including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse
sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 1,110.65 | sqm | 286.45 ₹3.2 L | 310 ₹3.4 L |
| 7.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 2,201.51 | CUM | 172.1 ₹3.8 L | 180 ₹4.0 L |
| 8.00 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | 1,118.49 | CUM | 170.96 ₹1.9 L | 65 ₹72,701.85 |
| 9.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 131.93 | CUM | 666.87 ₹87,980.16 | 550 ₹72,561.50 |
| 10.00 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 1,720.92 | SQM | 373.63 ₹6.4 L | 400 ₹6.9 L |
Tender Value
₹9.7 Cr
EMD Value
₹9.7 L
Closing Date
22 Jan 2026, 5:00 pmClosed
Project Director (Technical)
JUIDCO Bhavan, Kutchery Chowk
Construction of New Nagar Panchayat Office Building at Latehar under Latehar Nagar Panchayat
2026_UDD_109018_1
JUIDCO/NIT/OB Latehar/684
Open Tender
Civil Works
330 days
Latehar
Please refer Tender documents.
5 documents required · 5 mandatory
₹25,000
₹9.7 L
25 May 2026
15 Jan 2026
24 Jan 2026
15 Jan 2026
22 Jan 2026
15 Jan 2026
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Cutting of trees, excluding removal of stumps and roots of trees
Removal of stumps and roots including backfillinbg with suitable material to required compaction
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing average 150mm thick dry rammed khoa beaten to112mm.(compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thckness is achieved, curing and carriage of water with all leads,making proper slope and blending the top with cement morter (1:10) all complete as per building specification and direction of E/I
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. @ Size of Tile 600x600 mm .
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab colour black, Cherry/Ruby red
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-inCharge. Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying in position specified grade of cement concrete excluding the cost of centering shuttering finishing and reinforcement - All works upto plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand(zone III):3 graded stone concrete 20mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering - All works upto plinth level.: 1:2:4 (1 cement: 2 coarse sand(zone III):4 graded stone concrete 20mm nominal size)
Providing and laying cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : ,….. 1:2:4(1cement:2coarse sand (zone-III):4 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) included attached buttresses, string or lacing courses ,….. 1:2:4 (1 cement: 2 coarse sand(zone III):4 graded stone concrete 40mm nominal size)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 grade stone aggregate 20 mm nominal size).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :- Columns, Pillars, Piers, Abutments, Posts and Struts
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:8) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick ( flag) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. ( 1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints , cost of screening materials , raking out joints to 150 mm depth , curing , taxes and royalty all complete
Providing Designation 100A 112 mm thick reinforced B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:4) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including the cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 12 mm. cement plaster ( 1: 6) with clean coarse sand of F.M. 1.5 including screening , curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I.
providing two coats of dry distemper of approved shade and make over a primer coat of washing over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper ,applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction E/I.
Providing two coats of synthetic enamel paint over a coat of primer of approved shade and make over new wooden surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.
Providing two coats of painting with ready mix paint over a coat of primer of approved shade and make over new steel surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.
Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately)
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 10 MM
providing Tor steel reinforcement of 20mm,25mm,& 28mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 20 MM
Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.TRUSS
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat
Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)@ 12.29kg/sqm (Mumpty Room)
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1 mm thick
Providing and fixing bright finished brass 100 mm mortice latch andlock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Design, Manufacture and Installation of Skylight System of DPI daylighting/ Gallina or equivalent make, a complete assembly of extruded cellular structure UV protected polycarbonate panels incorporated into a complete system, co-extruded UV protected polycarbonate panel system of minimum 16mm thickness with panel width of 1050-1250 mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam with standing seam height of 10mm - 15mm at both sides of panel. Panels shall be of softlite / antiglare type prevent glare. Panels shall be fixed on purlins with continuous twin wall aluminium spacer and HD, polycarbonate U connectors, continuous twin wall aluminium spacer will be secured on MS structure with self drilling screws to ensure a pullout load of min 21000N (21KN) tested as per ISO 6892:1998 and IS 1608:2005. Polycarbonate panels also shall not have yellowness index as per ASTM D 1925 of 15 units when tested on sample exposed to UV for 500 hours as per ASTM G 155. The polycarbonate panels must satisfy dart drop impact test as per IS 14443-97 shall show no sign of breakage on plycarbonate sheets which have been exposed to UV for a min of 500 hours as per ASTM G 155.
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 12.59.1 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Exacavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.
Excavation for road way in soil by mechanical means including cutting and transporting the earth to site of embankment /dumping area with lead upto 1000 metres, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.
Excavation for roadway in ordinary rock by deploying a dozer, including cutting and transporting the earth to site of embankment /dumping area with lead upto 1000 metres, trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.
Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m
Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2.
Loosening, leveling and compacting orinal ground supporting embankment to facilitate placement of first layer of embankment , scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for emabakment construction.
Preparation and Surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with smooth wheeled roller,complete as per clause 310.
Granular sub base with coarse graded materils (Table:-400-2) (construction of granular sub-base by providing coarse graded materials ,spreading in uniform layers with mortor grader on preoared surface ,mixing ,by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density ,complete as per clause 401 ) (Grading 1 materials )
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.
Providing, laying and spreading soil on a prepared sub grade, pulverising, mixing the spread soil in place with rotavator with 3 per cent slaked lime with minimum content of 70 per cent of CaO, grading with motor grader and compacting with the road roller at OMC to achieve at least 98 per cent of the max dry density to form a layer of sub base.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M15 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) PCC M20 Cast In Situ
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 120 cm equilateral triangle
90 cm equilateral triangle
90 cm x 75 cm rectangular
80 cm x 60 cm rectangular
Direction and Place Identification Signs upto 0.9 sqm Size Board.(Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)
Direction and Place Identification Signs with size more than 0.9 sqm size Board.(Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2mm thickness and 4.5m meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
Providing tensile sheet roofing structure including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), including the cost of purlins, rafters and trusses and foundation work including cutting to size and shape wherever required as per the directions of engineer in charge.
Supplying and stacking at site dump manure from approved source,including carriage upto 5 km complete (manure measured in stacks will bereduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Dracaena Song of India (three in one), havinght. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Philodendron Burgundy mounted on moss stick 90 cm ht., well developed with full of fresh & healthy leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.
Providing and Displaying Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Foxtail palm of ht. 180-210 cm bottom girth 25- 30 cm well developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Michelia champa (Golden Champa) of height 90- 105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ipomoea purpurea (Morning glory) of height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Petra volubilis of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot / Plastic Pot.
Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Rabbit Dustbin
bench with backrest Wooden/ Treated Bamboo/ Bamboo composite planks Fitted in cast iron frame Painted/ Polished with protective laquer coat
Clearing of grass and removal of rubbish upto a distance of 50 mtrs. Outside the periphery of the area by manual means
Cost of drilling 200mm X 165mm X 125mm deep bore well in all kinds of soil and rock in rural area for installation of pump set withhydraulic DTH rig machine , all complete including supplying all materials , tools , drilling rig , air compresser and equipments, as well as fuel , lubricants and cost of transportation of rig machine and other vehical up to the site up to the site ( basic rates ) . (ADD 14.95% ON BASIC RATE FOR C.P.+O.H)
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm Dia.
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 5.0 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. Starter 10.0 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing C.P. brass 2 way bib cock of Jaquar make or equivalent(FLP-5041PM) conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm dia male ended C.I .Body brass spindle valve and seat bib cock of approved quality (wt not less than 400 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing 15 mm dia male ended C.I push cock (wt not less than 400 gms ) of approved quality with extra socket all complete as per specification and direction of E/l .
Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l .(A) BRASS STOP COCK(a) 15 mm dia
(b) 20 mm dia
Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l .
Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l.(b) C.I. body brass spindle
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l.(a) 15 mm dia wt not less than 300 gms
(a) 20mm dia wt not less than 400 gms
(a) 25 mm dia wt not less than 500 gms
(a) 32 mm dia wt not less than 700 gms
(a) 40 mm dia wt not less than 1kg
(a) 50 mm dia wt not less than 1.5 kg
Cutting drain width wise above G.L for laying G.I pipes and restoring with brick in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction of E/l
Cutting chajja or cornice for laying G.I pipe and restoring the same with R.C.C (1:2:4) brick work in cement mortar (1:4) and cement plaster (1:4) as per specification and direction of E/l.
Supplying tools and making connection of new G.I. distribution branch 15 mm to 50 mm dia with existing G.I main by providing and fixing G.I. tee including cutting of pipe at two places and threading their ends, providing long screw and G.I nipple all complete as per specification and direction of E/l.50 mm dia
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l.(a) Glass shelf with C.P brass rail (1) 600 x 125 mm
(b) Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirro(1)600x450 mm
( c) C.P brass towel rail 20 mm x 600 mm with bracket container
(2) C.P brass shop dish container medium quality with screw and hinges etc.
(3) C.P brass liquid shop container
Supplying materials and construction of brick masonry drain 150 mm width and 150mm depth with 250mm apron on both sides over 50mm thick P.C.C (1:3:6) over a brick flat soling, apron laying brick work in C.M (1:6). 12mm cement plaster (1:3) with punning on exposed surface all complete job as per specification and direction of E/l
Supplying materials and construction of 600x600x900mm stop cock chamber of brick masonary with 125mm thick work of designation 75B in cement mortar (1:6) with 12mm thick cement palster in C.M. (1:6) on inside only.having 50mm thick R.C.C. cover having 12mm dia lifting rings, 2 nos. stop cock chamber will rest over 80mm thick P.C.C. (1:3:6) over one brick flat soling, including cost of earthwork, all complete job, as per approved design, specification and direction of E/I.
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(b)10 lit. low level P.V.C. cistern
Providing and fixing kitchen sink including making all connection excluding cost of fitings. (white glazed fire clay sink of size 600x450x250 mm)
Supplying fitting and fixing H.C.I, pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars, lead and yarn for making lead chaulked joints, cutting pipes to size including earth work or scaffolding where neccessary etc. all complete as per specification and direction of E/l.(a) 100 mm dia
(b) 75 mm dia
(c) 50 mm dia
Supplying and fixing H.C.I, fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobins lead and yarn for making lead chaulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/l.(A) H.C.I, single junction with door but without ear except socket(i) 100mmdia(Wt. 10.5 Kg. app.)
(ii) 80 mm dia (Wt. 7 Kg. )
(B) H.C.I. Heal Rest Bend(i) 100 mm dia (Wt. 5.5 Kg. app.)
(ii) 80 mm dia (Wt. 4 Kg. app.)
(iii) 50mm dia (Wt. 3.5 Kn. app.)
(C) 100mm dia H.C.I."P" TRAP with Anti syphonage Horn (Wt. 8.5 Kg. app.)
(D) H.C.I, double junction with door and ear(i) 100 mm dia (Wt. 15.5 Kg. app.)
(ii) 80 mm dia (Wt. 15.5 Kg. app.)
(iii) 50 mm dia (Wt. 6 Kg. app.)
(E) H.C.I, double inverted Jn.(100 mm x 50 mm x 50 mm size)
(F) H.C.I, offset with ear(i) 100 mm dia (Wt. 6 Kg. app.)
(ii) 80 mm dia (Wt. 4 Kg. app. )
(iii) 50 mm dia (Wt. 3.26 Kg. app.)
(G) H.C.I, bend with door and ear(i) 100 mm dia (Wt. 6.5 Kg. app.)
(ii) 80 mm dia (Wt. 4.5 Kg. app.)
(iii) 50 mm dia (Wt. 4 Kg. app.)
(H) H.C.I plain bend with ear(i) 100mm dia (Wt. 5.5 Kg. app.)
(ii) 80 mm dia (Wt. 3.75 Kg. app.)
(iii) 50 mm dia (Wt. 3.25 Kg. app.)
(I) Floor trap with gratinqs(i) 100 mm dia
(J) Norton patent H.C.I, cowl(i) 100 mm dia (Wt. 3.25 Kg. app.)
(ii) 80 mm dia (Wt. 2.25 Kg. app.)
(iii) 50 mm dia (Wt. 1 Kg. app.)
ID H.C.I. pass over(i) 100 mm dia
(iii) 50 mm dia
(M) H.C.I, sinqle inverted junction with ear(100 mm x50 mm)
Making holes in wall for laying H.C.I, pipe and restoring the same after pipe laying as per specification and direction of E/l.(i) 125 mm dia
(ii) 250 mm dia
(iii) 375 mm dia
(iv) 500 mm dia
(v) R.C.C. chajja
Supplying materials and labours for painting the exposed H.C.I, pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(i) 50 mm dia
(ii) 80 mm dia
(iii) 100 mm dia
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion.110mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion.Coupler 110 mm dia
Single Tee with door
Bend 87.5 deg 110 mm
110mm PVC Shoe
Providing and fixing unplasticised- PVC pipe clip of approved desing to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwes with M.S. Screw of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse sand ) and making good the wall etc. complete.110mm dia
Providing and fixing white vitreous china battery based infrared sensor operated urinal of appx.size 610x390x370mm having pre & post flushing with water (250ml & 500ml consumption) having water inlet from back side,including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):65 mm nominal bore
80 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end ).50 mm dia nominal bore-vertical
65 mm dia nominal bore-vertical
80 mm dia nominal bore-vertical
Providing and fixing C.I sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):100mm diameter.Class II
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931.15 mm nominal bore
Constructing brick masonry road gully chamber 50 X 45 X 60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500 X 450 mm precast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with pre-cast R.C.C. vertical grating complete as per standard design: With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm pre-cast R.C.C. horizontal grating with frame & vertical grating complete as per standard design:With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Supplying pig lead at site of work
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
Providing and placing on terrace (at all floor levels) storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m.up to 1.50 m depth Pipes 80 mm to 300 mm diameter
1.50 m to 3.00 m depth Pipes 80 mm to 300 mm diameter
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. complete.150 mm. dia. RCC Pipes
250 mm. dia. RCC Pipes
300 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipes including bed concrete as per standard design.150 mm. dia. RCC Pipes
250 mm. dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunces of SW pipes including bed concrete as per standard design.300 mm. dia. RCC Pipes
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.Inside size 90 x 80 cm and 45 cm deep including CI cover with frame(medium duty) 500mm internal diameter, total weight of cover and frame to be not less than116 kg (weight of cover 58 kg and weight of frame 58 kg).-With FPS bricks of class designation 75.
Inside size 120 X 90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg).With FPS bricks of class designation 75
Extra for depth for manholes .Size 90x80cm with FPS bricks of class designation 75
Size 120x90cm with FPS bricks of class designation 75
Constructing brick masonry circular type manhole 0.91 M. internal dia at bottom and 0.56 M. dia at top in cement mortar 1:4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement all complete as per standard design.0.91 M deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 gradded stone aggregate of 20 mm nominal size) including centering shuttering all complete. (Excavation, footrest and 12 mm thick cement plaster at the external surface shall be paid for separately) (with common burnt clay FPS (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91 m internal dia at bottom with F.P.S. bricks beyond 0.91 m to 1.67 m.
Constructing brick masonry circular manhole 1.22 M. internal dia at bottom and 0.56 M. dia at top with F.P.S. bricks in cement mortar 1:4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement all complete as per standard design.1.68 M deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS : 12592, total weight of cover and frame to be not less than 182 kg.,fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregate of 20 mm nominal sige) including centering shuttering all complete. (Excavation, footrest and 12 mm thick cement plaster at the external surface shall be paid for separately)
Providing M.S. foot rests including fixing in manholes with 20*20*10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) as per standard design : with 20 x 20 mm square bar
Providing and fixing square mouth SW gully trap class SP-1 complete CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg. as per standard design.100x100mm size P type.With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
180x150mm size P type.With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required.White vitreous china wash basin size 630 mm x 450 mm with a single 15mm CP brass pillar tap.
Providing & fixing in position storage type hot water electrical geyser (vertical or horizontal-1.5 kw) including making connection in all respects.-Venus/Racold make.Cap-25 lts
Supply installation testing and commissioning R.O.water purifier comprising 5 micron filter and UV steriliser on cold water supply to work on single phase 230 volts 50 HZ AC power supply with capacity 120 lph.-Kent/approved equal make.
Providing & fixing Sink Mixer with Swinging Casted Spout (Wall Mounted Jaquar model CON-319 KNB/approved equal) with 450mm long copper pipes & brass nuts.
Providing and fixing G.I. Inlet fitting of suitable size with 1 to 3 Nos. G.I. Sockets of 32 to 50 dia welded to G.I. pipe 100mm dia and dipped in hot bitumen complete in all respect.
Providing & fixing 100m x 50mm G.I. waste with G.I. reducer including 102mm dia CP Glossy Grating Jayna model no. RRB 102),cutting chases in the floor / slab complete as required.
Providing and fixing brass clean out plug with suitable inlet key for opening male threaded joint with pipe & socket complete as required.
Providing , hoisting & fixing in position CI drain heavy duty cover of required size and thickness with lifting hooks etc. (perforated) as per drg. and as directed by Engineer-in-charge, complete in all respect.Size 450x450mm
Constructing Oil & Grease Chamber size 2400x1000mm internal size of 1000mm depth in brick work of class 75 with cement mortar (1:5) Inside 12mm thick with cement mortar 1:3 with floating coat of neat cement and rough plaster on outside, RCC top slab with 500mm dia medium duty manhole cover with frame (weight of cover 58 kg. & weight of frame 58 kg.), 150mm thick foundation concrete (1 :4 : 8), necessary excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required.
Providing, fixing, jointing and testing in position the Centrifugally Cast iron pipes for soil, waste and vent installation conforming to I.S. 3989 cut to required lengths. including all fittings like tees,bends,door bends,cleanout plugs,supports,structural steel supports,painting of pipes and all supports,lead joints, cutting & making good RCC/brick walls,core cutting wherever required & directed at site cutting chases/holes in floors /walls/ slab etc and making good the same complete.(a) 150 mm dia centrifugally cast (spun) iron S&S pipe
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280lpm at 70m head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280lpm at 70m head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180lpm at 70m head
Supply, installation and testing of cylindrical type flanged pressure vessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of hydrant and sprinkler fire pumps including flanged connection, suitable supporting legs etc. The air vessel tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 50 mm dia drain valve, suitable pressure switches to operate main pumps and jockey pumps, tested to min 25 KG/cm2 complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge.
Supply & erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions of Engineer-in-charge. (MAKE : Minimax / Cease Fire / Safex / Padmini / Newage)Water CO2 gas nozzle type. 9 Lt.capacity (IS:15683)
Supply & fixing of 4 nos. G.I. round bottom fire buckets of 9.5 liters capacity filled with sand including proper supporting / mounting arrangements in MS angle iron frame, painted by fire red colour over two coats of red oxide paint and written with white paint "FIRE" complete in all respects as per the directions of Engineer-in-charge.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25mm
200mm dia (wall thickness =6.3mm)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 200mm dia (wall thickness =6.3mm)
150mm dia
Providing & fixing neoprene rubber single arch double flanged flexicon rubber expansion joint (anti vibration bellow) of standard lengtg as per manufacturers specifications. Tested to a pressure of 16 Kg/Cm2 including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. (Make : Easyflex / Resistoflex / Kanwal).80 mm dia.
150 mm dia.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 50mm dia
80mm dia
100mm dia
150mm dia
200mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80mm
Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444) and hose reel suitable for 10 kg/sqcm operating pressure for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, 5 mm dia shut off Stainless steel nozzle, connecting directly from the riser through 40 mm dia. MS (Class C) pipe with sockets, elbows, nipples, 40x20 mm reducer, 20 dia pipe, 20 mm dia. hand lever operated isolating ball valve, etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (MAKE : Newage / Safeguard / Padmini).
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handel usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve,safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint including The tank shall be installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
25mm Air release valve as per IS:14845 ISI Marked
Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipe complete in all respects. (Make : H Guru / FIBIG)
18.19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way - 150 mm dia M.S. Pipe
Providing and fixing of cast iron body 150 mm dia Draw out connection in Under ground water storage tank with heavy class MS suction pipe of required length, foot valve, suction coupling in conformity with local regulations complete in all respects. (MAKE : Newage / Safeguard / Padmini )
Providing and fixing C I body flanged S S strainer fabricated out of 1.6 mm thick Stainless Steel 304 sheet with 3 mm dia hole, min test pressure 16 kg/sqcm complete. (Make : Zoloto / Vaishno / Advance / Audco / SKS)200 mm dia
Providing and fixing weather proof standard fire hose cabinet (600 mm x 600 mm x 450 mm) outdoor type made of not less than 14 SWG MS sheet having glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing hydrant valve, two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type painted MS Angle iron frame as required. The words "FIRE HOSE" to be painted on the box.
Providing and fixing weather proof standard fire hose cabinet (900 mm x 1800 mm x 600 mm) outdoor type made of not less than 14 SWG MS sheet having glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing hydrant valve, two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type painted MS Angle iron frame as required. The words "FIRE HOSE" to be painted on the box.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
Providing & fixing cast iron foot valve complete with flange.-150mm dia.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : PENDENT SPRINKLER
HORIZONTAL SIDE WALL SPRINKLER
UPRIGHT SPRINKLER
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 80MM DIA
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing and fixing signages as per required content printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating with suitable colour combination (Glow in dark) with high intensity properties for indoor surface glow visibility not less than 6 hrs. in total darkness and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR Double sided signage board
Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.Internal Work - Exposed on Wall. 15mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
40 mm nominal outer dia pipes.
50 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.Internal work exposed on wall.15mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40mm dia nominal bore
50mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work-15mm dia. nominal bore
20mm dia. nominal bore
25mm dia. nominal bore
32mm dia. nominal bore
40mm dia. nominal bore
50mm dia. nominal bore
65mm dia. nominal bore
80mm dia. nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe.
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Painting G.I. Pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality:15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing & fixing G.I. union in G.I. Pipe including cutting & threading the pipe & making long screws etc. complete( New work):15mm dia. nominal bore
20mm dia. nominal bore
25mm dia. nominal bore
32mm dia. nominal bore
40mm dia. nominal bore
50mm dia. nominal bore
65mm dia. nominal bore
80mm dia. nominal bore
Providing & fixing 6mm thick nitryl rubber insulation on hot water pipes-15 to 50 mm dia pipes burried inside walls.
Providing & fixing 12mm thick nitryl rubber insulation on hot water pipes-15 to 54 mm dia exposed
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80MM DIA
Providing & wrapping burried G.I. pipes and fittings with 4mm thick pypcoat all around the pipe in external work.15 mm diameter pipes
20 mm diameter pipes
25 mm diameter pipes
32 mm diameter pipes
40 mm diameter pipes
50 mm diameter pipes
65 mm diameter pipes
80 mm diameter pipes
Providing and fixing M.S. puddle flanges fabricated out of 6 mm thick M.S. plate of size 200 x 200mm plus dia of pipe of 600 mm long pipe pieces to R.C.C. water tanks / R.C.C. walls. The entire fitting shall be painted with black Japan paint .25 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing and fixing electronic water level indicator with specified nos of level indications including p/f prons in overhead tank, necessary cabling from level indicating panel to prones in over head tank (upto 5 metre length) in proper manner as per specification and direction of Engineer. 5 level indications
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.Internal Work - Exposed on Wall(a) 62.50 mm nominal inner dia pipes.
b) 75 mm nominal inner dia pipes.
Supply and installation testing & commisioning of 100kVA transformer step down outdoor type complete with standard fittings HT 11 KV 3 phase 4 wire copper wound, delta/star connected (vector group-DYn -11), On load Tapp Changer on HV side , oil immersed, naturally oil cooled (ONAN), Distribution transformer complete with following:-(a) Silica gel breather with connecting pipe and oil seal.(b)Air release plugs.(c)Pressure release device. Explosion vent, should be double diaphragm type.(d)150mm dial magnetic oil level gauge with low level alarm contact.(e)150 mm dial oil temperature indicator with maximum reading pointer and electrically separate contacts for trip and alarm.(f)150 mm dial winding temperature indicator with maximum reading pointer and electrically separate sets of contacts for trip and alarm.(g)Thermometer pockets.(h)Oil conservator with filter cap, drain plug and plain oil level gauge (with coloured prismatic front).(i)Double float Buchholz relay with gas release cock, shut-off valve on either side and separate sets of contacts for trip and alarm.(j)Sampling valve/ Filter valve with threaded adopted (top and bottom).(k)Drain valve with threaded adopted.(l)Jacking pads, handling and lifting lugs.(m)Cover lifting eyes.(n)Bi-directional rollers and skids( 4 Nos. Roller)(o)Radiators (Detachable type).(p)Clamping devices.(q)Two grounding pads.(r)Remote tap changer control panel.( RTCC)(s)Weatherproof marshalling box for housing control equipment and terminal connections.(t)Rating and terminal marking plates.(u)LT Neutral bushing with 32x6 cu flat suitably supported (v)Outdoor HT cable box (Detachable type) suitable to terminate 3C-95 sq. mm 11kV HT cable.(w)Outdoor Lt cable box suitable to terminate 2 Nos. 3.5C-150 sq. mm Al Armoured LT cable. 250 KVA Transformer as per above
SUB-HEAD II: H.T & L.T CABLE Supply of 3c-95 sq .mm cable XLPE -PVC insulated PVC sheathed galvanised steel strip armoured electric power cable with aluminium conductor 11000 volt grade
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 3c x 95 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/STONE WARE / METAL pipe as required. 3c x 95 sqmm
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm
Supplying of following 1100 volt grade XLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specification as required. 3.5 core 185sq. mm.
3.5 core 150sq. mm.
3.5 core 70sq. mm.
3.5 core 50sq. mm.
3.5 core 35sq. mm.
4 core 16 sq. mm.
4 core 10 sq. mm.
4 core 4sq. mm.( Copper)
3 core 6 sq. mm.( Copper)
5 core 2.5sq. mm.( Copper)
3 core 1.5sq. mm.( Copper)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a)Upto 25 sq. mm
(b)Above 25 sq. mm and upto 120 sq. mm
(c)Above 120 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a)Upto 25 sq. mm
(b)Above 25 sq. mm and upto 120 sq. mm
(c)Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required. (a)Upto 25 sq. mm
(b)Above 25 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing mansory open duct as required. (a)Upto 25 sq. mm
(b)Above 25 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade. 3.5 core 185sq. mm.
3.5 core 150sq. mm.
3.5 core 70sq. mm.
3.5 core 50sq. mm.
3.5 core 35sq. mm.
4 core 25sq. mm.
4 core 10sq. mm.
Supply, erection, testing & commissioning of prefabricated GI. ladder type cable trays including Crossing Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required. 600 (W) x 50 (H) x 2mm (T)
450 (W) x 50 (H) x 2mm (T)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm dia
150 mm dia
250 mmdia
Supply and laying of the following uPVC pipe(4 KgF) including excavation, refilling as required for cable entry including the cost of sealing the ends as required complete. 200mm outer dia
100mm outer dia
Ground Floor MDB 10 kA( Wall Mounted)Incoming1 Nos. 125A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication-6 parameter Energy Analyser complete with CTs / Control MCBs as required,R-Y-B and ON/OFF indication lamps for incomer with control MCB.Bus Bar:160A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.Outgoings:1 Nos. 40A, DP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- 3 nos. 63 amp TPN MCB( Motor Duty ),1 nos. 40 amp TPN MCB( Motor Duty ),2 nos. 25 amp TPN MCB( Motor Duty ).Typical Office MDB as described above and complete as per enclosed SLD
First Floor MDB 10 kA( Wall Mounted)Incoming-1 Nos. 160A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:-Metering & Indication-6 parameter Energy Analyser complete with CTs / Control MCBs as required,R-Y-B and ON/OFF indication lamps for incomer with control MCB,Bus Bar:200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.Outgoings:1 Nos. 80A, DP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:-4 nos. 63 amp TPN MCB( Motor Duty ),3 nos. 40 amp TPN MCB( Motor Duty ),First Floor MDB as described above and complete as per enclosed SLD
Second Floor MDB 10 kA( Wall Mounted)Incoming:-1 Nos. 125A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication-6 parameter Energy Analyser complete with CTs / Control MCBs as required,R-Y-B and ON/OFF indication lamps for incomer with control MCB.Bus Bar:150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.Outgoings:1 Nos. 40A, DP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- 3 nos. 63 amp TPN MCB( Motor Duty ),3 nos. 40 amp TPN MCB( Motor Duty ).Second Floor as described above and complete as per enclosed SLD
Third Floor MDB 10 kA( Wall Mounted)Incoming:-1 Nos. 125A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication-6 parameter Energy Analyser complete with CTs / Control MCBs as required,R-Y-B and ON/OFF indication lamps for incomer with control MCB.Bus Bar:150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.Outgoings:1 Nos. 40A, DP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- 3 nos. 63 amp TPN MCB( Motor Duty ),3 nos. 40 amp TPN MCB( Motor Duty ).Third Floor as described above and complete as per enclosed SLD
Basement MDB Type -1 - 10 kA.Incoming:-1 Nos. 160A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication-6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 160/5A cast resin type CL: 1.0 CTs and MCB,R-Y-B and ON/OFF indication lamps for incomer with control MCB.Bus Bar:200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 20 kA. Neutral busbar shall be of 100% capacity.Outgoings:8 nos. 40 amp TPN MCB( Motor Duty ),2 nos. 25 amp TPN MCB( Motor Duty ),2 nos. 32 amp TPN MCB( Motor Duty ).Basement MDB as described above and complete as per enclosed SLD
Supply , installation , Testing andf commisioning of 1 No. 630A, TPN Isolator outdoor type Floor standing enclosure , with RYB indivcation Lamps and suitable for 2 Nos. 3.5- 185 Sq. mm AL srm Incoming and outgoing cable
SUB-HEAD IV: EARTHING AND LIGHTNING PROTECTION:EARTHING-Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( without charcoal or coke and salt).
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( without charcoal or coke and salt).
Supply and laying 25mmX5 MM GI strip at 0.50 meter below ground as strip earth electrode including soldering etc as required
Supply and laying 25mmX6 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode
Providing and fixing 25 mm X 5 mm Cu. strip in 40 mm dia G.I. pipe from earth electrode
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing earth bush of 50mmX 5mm copper strip on surface for connections etc. as required
LIGHTNING PROTECTION:-Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 6 mm thick G.I base plate including holes etc. complete as required.
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for horizontal)
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.
Providing and laying COPPER tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.
Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( without charcoal or coke and salt).
7 mtr high octagonal hot-dip galvanised pole(BOP-7030) with top dia 70mm, bottom dia 130mm & made of 3 mm thick sheet, base plate dimensions 200mmX200mmX12mm (LXBXT) including suitable sizes of foundation bolt all complete as reqd. (without arm
Erection Of metallic street light standard pole of length exceeding 4.5mtrs but not exceding 6.5mtrs in in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregated 40mm nominal size) foundation with cement concerete collar of size 0.4m dia X 0.5m dia height to accomodate the looping type cable end box including excabation and refilling etc as required
LED STREET LIGHT (90/100W)
0.5 M SINGLE ARM SUITABLE FOR 70MM TOP
Supply of following sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required.(a)2C x 6 sq mm
(b)2C x 10 sq mm
(c)2C x 16 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 25 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 25 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.Upto 25 sq. mm
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.(a)2C x 6 sq mm
(b)2C x 10 sq mm
(c)2C x 16 sq mm
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc as required ( but with out charcoal/coke and salt )
Supplying and fixing 50mm dia GI pipe on the pole for cable entry to junction box as required.
Silent type D.G Set of capacity 100 KVA With AMF Panel IS/IEC-60034-1 IS: 1460 IS: 13018
Supply, laying of following sizes of MS Piping for Exhaust including providing suitable bends, reducers & supporting arrangement at suitable intervals including insulation on entire length of exhaust pipe with 50mm thick Rockwool insulation & painting etc. as required.150mm (NB) MS ERW pipe
5 KVA online UPS single phase input and single phase system of input Voltage range 110V AC ± 5% Frequency range 40Hz - 60Hz, Power Factor ≥ 0.90 @ full load and output voltage range 200V/208/220/230/240V AC, voltage regulation ± 1% Frequency range 50Hz ±0.25Hz or 60Hz ±0.30Hz Harmonic distortion -< 2% THD(non-linear load) efficiency - 88/83%
LED BULB 15/16W
Recess mounting LED round down light(6/7W)
Ceiling fans:Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm
electronic step fan ragulator deluxe
Installation, testing and commissioning of ceiling fans/bracket fan of all sizes including wiring the down rod .of standard length (up to 30 cm ) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required.
Supplying, Installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper wire suitable for 230V 50 Hz, single phase supply etc. complete as required. 1200mm (48") BLDC 5 star rating 32w ceiling fan
16" (400 mm) Wall mounted fan
12" (300mm) metal exhaust fan
Installation of exhaust up to 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required
Extra for fixing the louvers/ shutters complete with Frame for a exhaust fan of all sizes
LIFT Supply, installation, testing & commissioning of electric traction type elevator of following capacities and type suitable for operation on 415 V, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency type traction control, machine room less, speed of 1.00 Mtr/sec, electromagnetic brake system, simple operations, operating control panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman?s switch at ground floor, digital car positions indicator in car and at all positions indicator in car and at all floors with Up/DOWN direction, all signal fixtures in stainless steel faceplates, light fixtures, ventilation fan, etc complete with all accessories including automatic rescue device in the event of power failure etc., Complete with necessary scaffolding, electrical panel, logic control panel and shaft lighting etc required for the erection of the elevators as required.Position of Machine Directly above the lift well - elevator shall be of gearless type (suitable for lift well size 2200mm (W)X 2100m(D)) complete as per technical specification, micro processor based simplex full collective operation with/without attendant. Car/Hoistway Entrance, protected by stainless steel hairline doors and clear center /side opening min 900mm wide X 2000mm height capacity (minimum 408 Kgs)8 Passenger Lift , car size of 1800x1700x2200 (mm wide*mm depth *mm height*mm C - value) ....
Honeywell or Equal only Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.25mm dia
32mm dia
Supplying and laying of following sizes FRLS PVC insulated single core copper wire in existing conduit complete as required.2x1.5 sq mm
2x2.5 sq mm
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing and commissioning of addressable control switches for shutting down AHUs Lifts etc.
Supplying, installation, testing and commissioning of short circuit fault isolator with all labour and material as required to complete the job in all respects upto the entire satisfaction of engineer in charge
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch ,modular plate ,suitable GI box as required.(a) Group - C
Wiring for twin controlled light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 2 way modular switch ,modular plate ,suitable GI box etc as required.
Wiring for light/ceiling fan/exhaust fan/call bell point with 2x1.5 sq.mm PVC insulated stranded copper conductor cable alongwith 1 No. 1.5 sq.mm PVC insulated copper conductor cable for earthing in PVC Medium conduit as required. (Point shall be controlled / looped Fromexisting point).(1.3.3)
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For primary 5A Socket and Primary MCB Point)
Wiring for Circuit wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Circuit wiring) for circuit sub main 2x1.5sqm+1x1.5 sqmm+1x1.5)
Wiring with 2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Secondary MCB Points and 5A Secondary Points)
Wiring for light / power plug point with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC Medium Class conduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)circuit sub main
Wiring for light / power plug point with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For A/C Sockets)
DB SUBMAIN WIRING IN PVC CONDUITS:Wiring for DB submain with 4 x 16 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 2 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 4 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 2 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 2 x 16 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 2 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
POWER SOCKETS Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.20mm dia
25mm dia
32mm dia
Supplying installation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheet steel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar inter connection and powder coated including earthing eytc as required (Without MCBs . RCCBs , Isolator etc as required).(TPN DB( Double door)A. TP&N D.B (HORIZONTAL TYPE) 8 way double door
. 63 Amps 4P MCB Isolator
. 63 Amps 2P RCCB -
. 6-32 Amps SP MCBs as outgoing
. 40 Amps 4P MCB Isolator
40 Amps 2P RCCB
Supplying installation, testing and commissioning of surface-recess mounting type Siingle pole and neutral,prewired, sheet steel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate,, phosphatized and powder painted including earthing etc. as required without MCBs . RCCBs , Isolator etc as required. SP&N D.B (HORIZONTAL TYPE) 12 way single door
(i) 1 No. 40 Amps 2P RCCB -1Nos
(ii) 10 Nos. 6-32 Amps SP MCBs as outgoing
SP&N D.B (HORIZONTAL TYPE)12 way single door
(i) 63 Amps 2P RCCB -1Nos
(ii) 6-32 Amps SP MCBs as outgoing
(i)25 Amps 2P RCCB -1Nos
(ii) 6-32 Amps SP MCBs as outgoing
SUB-HEAD XI : IP BASED CCTV SYSTEM( COLOURED)- Honeywell or equalvelant only Supply, installation, testing and commissioning of IP Based outdoor Pan/Tilt/Zoom cameras including integrated Housing , Connectors, Lens, Camera Mounts,Power Supply , PTZ ket board controller and all Ancillary Equipment & all accessories including Remote Reciever Unit and Pan Tilt Unit (including driver cables).Wall / Ceiling mounted
Supply, installation, testing and commissioning of IP based Fixed indoor veri focal lences auto iris cameras 1.3 MP including integrated housing (dome type), Connectors, A.I.Lens, Camera Mounts,Power Supply and all Ancillary Equipment & all accessories.
Supply, installation, testing and commissioning of IP based Fixed veri focal lences auto iris 1.3 MP cameras including integrated housing (Bullet type), Connectors, A.I.Lens, Camera Mounts,Power Supply and all Ancillary Equipment & all accessories.
Supply, installation, testing and commissioning of 32 input duplex multiplexer with 2 video outputs with suitable Hard Disk facility recording(30 Days Backups) including all controllers/ software etc as required for above cameras( 32 Channel NVR)
Supply, installation, testing and commissioning of 42 u Rack with accessories ( 800/1000) Net Rack Shelf Full Tray (6 Nos.), 2 No. Vertical Power Manager with Cooling Fan Tray etc as required
Supply, laying, termination and testing of 32" LED TV( Full HD) with wall mounting kit and including all other accessories as required
Supply, laying, termination and testing of 24 Port POE switch including all other accessories as required Approved Make
Supply, laying, termination and testing of 8 Port POE switch including all other accessories as required Approved Make
Supply and Laying of Cat-6 Cable in existing conduits for Cameras Approved Make
Supply and Laying of Optical fibre 6 Core Single mode cable ( Finolex or Equal make) Approved Make
Supply and Laying of 3C-2.5 Sq. mm unarmoured Power Cable in existing conduits for Cameras power supply ISI MARKED
Supply and Laying of 63mm HDPI pipe with all accessories for laying fibre/ cable in outdoor areas ISI MARKED
Supply , Installation , testing and commisioning of 2.5 kVA UPS ( 1 Phase input and 1 Phase output) with 30 Minutes back up complete with batteries etc. ISI MARKED approved Make
Supply , Installation , testing and commisioning of all accessories to complete the CCTV system integration like Jack Panels , Giga Byte switches , weatherproof racks , Indoor type racks with power manager , sintex boxes for POE switches , OFC to RJ-45 Media convertor , LIU boxes etc with all software as required for above cameras approved Make
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.20mm dia
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.25mm dia
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.32mm dia
SAND(25 Km radius)
Bricks(18 Km radius)
AGGREGATE(25 KM RADIUS)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
SBDLa.pdf
Tender Documents • 9.30 MB
LATEHARMERGEDDRAWINGS.PDF
Additional Documents • 3.31 MB
BOQ_147278.xls
BOQ • 0.85 MB
Download all tender documents and submit your bid