AGE (I) Ayodhya
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
REP MAINT REWIRING/IMPROVEMENT OF INTERNAL ELECTRIFICATION WORKS ALONGWITH FITTINGS FIXTURES AND REPLACEMENT OF BURNT UNSV DISTIBUTION BOARD ALONGWITH EARTHING AND MISC WORKS FOR OTM AND MD ACCN AREA OF 146 INF BDE UNDER AGE (I) AYODHYA.
2026_MES_791476_1
8400/222/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Ayodhya
All as per NIT and Tender Documents
8 documents required · 8 mandatory
₹500
AGE (I) Ayodhya Cantt
₹50,000
Yes
28 Sept 2026
28 Sept 2026
27 Oct 2026
29 Sept 2026
19 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/ aluminium point wiring (light, fan,call bell,two way, socket or power) complete along with fittings such as switches, ceiling roses, Pendants, regulators, tube fittings and other kits & fittings. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/location all as specified and as directed. | 490 | Each Point | 1.25 | ₹612.5 |
| 2 | M&L in repair for point wiring concelaed with 1.5 Sqmm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through rigid non metallic PVC conduit not less than 20mm size, medium grade with all necessary fittings, concealed wiring , for one light/fan/socket/bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC rectangular block with 3 mm thick plastic laminated sheet cover of suitable size for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. and colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and directed by Engr-in-Charge. | 30 | Per Point | - | - |
| 3 | All as above ser item No 2.00 but with PVC casing n caping complete all as specified and as directed by Engr-in-Charge. | 80 | Per Point | -1.25 | - |
| 4 | All as above ser item No 2.00 but with existing conduit complete all as specified and as directed by Engr-in-Charge. | 80 | Per Point | -2.5 | - |
| 5 | All as per item No 2.00 here-in-above but for one light point controlled by two nos of 2 way switches complete all as specified and as directed by Engr-in-Charge. | 20 | Per Point | -3.75 | - |
| 6 | All as per item No 2.00 here-in-before but One 3 pin socket outlet 5/6 Amps on the same board with other switches with cables 1.5 Sqmm size complete all as specified and directed by Engineer-in-Charge. | 60 | Per Point | -5 | - |
| 7 | All as per item No 2.00 here – in – before but for one 3 / 5 -pin switch socket outlet 5/6 amps on independent board complete all as specified and directed by Engineer-in-Charge.. | 90 | Per Point | -6.25 | - |
| 8 | M & L for point wiring for one switch socket outlet 15/16 Amps on independent board with 2.5 Sqmm (nominal cross-sectional area) FRLS-H PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including metal flush boxes with 3mm thick plastic laminated sheet top cover complete including FR PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly ,complete all as specified cutting ,chases and making good as per existing specification and colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete. | 130 | Per Point | -7.5 | - |
| 9 | M&L in repair in repair/replacment submain wiring including taking down with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 4.00 Sq mm drawn through existing conduit not less than 20 mm size ISI marked with all fittings / accessories and one 4.00 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire connected to earth dolly including colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and as directed by Engr-in-Charge.
Note :- (i) Two run of single core cable and one run of earth wire will be measured as one length
(ii) All copper conductor shall be connected to MCBs/Switches etc with copper lugs/Thimble | 50 | RM | -8.75 | - |
| 10 | M&L in repair in repair/replacment submain wiring including taking down with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 4.00 Sq mm drawn through PVC casing /caping of suitable size ISI marked with all fittings / accessories and one 4.00 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire connected to earth dolly including colour coding of copper conductor ie for Phase-Red/Yellow/Blue, Neutral-Black and Earth wire-Green colour complete all as specified and as directed by Engr-in-Charge.
Note :- (i) Two run of single core cable and one run of earth wire will be measured as one length
(ii) All copper conductor shall be connected to MCBs/Switches etc with copper lugs/Thimble | 430 | RM | -10 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
TENDERDOCS.pdf
Tender Documents • 0.66 MB
BOQ_887335.xls
BOQ • 0.32 MB
MakeList.pdf
Additional Documents • 3.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .