Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 CrAccepted-AOC NO 406 ERODE KARUR MAIN ROAD THAMARAIPALAYAM ERODE 638152 | ERODE | ERODE | TAMIL NADU | 638152 | ₹13.5 Cr Quoted ₹11.7 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹11.9 CrRejected-Finance NO 93 KADAL THOTTAM VADAPALANI KUMARAPALAYAM POST NATHAKADAIYUR VIA ERODE 638 108 | ERODE | TAMIL NADU | 638108 | ₹11.9 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹12.0 CrRejected-Finance NO 21 ANAIGOUNDEN PUDUR VELLOTTAMPARAPPU POST ERODE TAMIL NADU 638154 | ERODE | TAMIL NADU | 638154 | ₹12.0 Cr | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | kadal constructions L2 | PONKULALI AND CO L3 | SHRINIDHI INFRRA L1 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORK | ||||||
| 2.00 | Clearing scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification. | 1,020 | Sqm | 11 ₹11,220 | 12 ₹12,240 | 10 ₹10,200 |
| 3.00 | Providing and constructing cast in situ hydraulic bored piles of 600mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. | 1,140 | Rmt | 5,900 ₹67.3 L | 6,000 ₹68.4 L | 6,500 ₹74.1 L |
| 4.00Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc ., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). | ||||||
| 5.00Carrying out initial Working pile load test on specified dia piles as specified in IS:2911 (Part 4). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete. | ||||||
| 6.00 | 600mm Dia Pile | 1 | Nos | 6,40,000 ₹6.4 L | 6,50,000 ₹6.5 L | 6,30,000 ₹6.3 L |
| 7.00Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders etc., As per SS 20B excluding hard rock requiring blasting Inclusive of 17,23 shoring shuttering, baling out water where ever necessary 24 and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers | ||||||
| 8.00 | Up to 1.5 m depth | 540 | Cum | 350 ₹1.9 L | 350 ₹1.9 L | 300 ₹1.6 L |
| 9.00 | Conway the excavated earth material within the site and deposited on banks and foundation of other structures to meet the requirment including refilling, consoildation with power Roller, loading, unloading all labour & hire charges of all machineries, Transportation etc., as per the directions of the departmental officers. | 350 | Cum | 380 ₹1.3 L | 400 ₹1.4 L | 360 ₹1.3 L |
| 10.00 | Construction of Embankment with approved Earth materials deposited at site and having on earth work excavation deposited on banks and foundation of otherb structures to meet the requirement including refilling consolidation, and all lead lift, Loading, Unloading, all labour, hire charge of all machineries, Transportation complete in all respects with all incidental charges and as per the directions of departmn[ent oficers/Enginner in charge of the work | 645 | Cum | 1,400 ₹9.0 L | 1,500 ₹9.7 L | 1,700 ₹11.0 L |
Tender Value
Refer Docs
EMD Value
₹5.8 L
Closing Date
10 Jul 2025, 3:00 pmClosed
Superintending Engineer I
Superintending Engineer-I, CW, CMDA, Koyambedu, Chennai
Construction of K 5 Police Station at Peravallur Kolathur Chennai
2025_CMDAC_576533_1
Tender Notice No.4a/2025-26
Open Tender
Civil Works - Others
270 days
Peravallur, Kolathur
Registration of Contractor, Annual Turnover, Similar Work experience, GST Registration, Income Tax Return, Site Visit Certificate
7 documents required · 7 mandatory
₹0
₹5.8 L
Yes
3 Mar 2026
1 Jul 2025
11 Jul 2025
1 Jul 2025
10 Jul 2025
2 Jul 2025
Amount
CIVIL WORK
Clearing scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification.
Providing and constructing cast in situ hydraulic bored piles of 600mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site.
Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc ., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).
Carrying out initial Working pile load test on specified dia piles as specified in IS:2911 (Part 4). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete.
600mm Dia Pile
Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders etc., As per SS 20B excluding hard rock requiring blasting Inclusive of 17,23 shoring shuttering, baling out water where ever necessary 24 and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers
Up to 1.5 m depth
Conway the excavated earth material within the site and deposited on banks and foundation of other structures to meet the requirment including refilling, consoildation with power Roller, loading, unloading all labour & hire charges of all machineries, Transportation etc., as per the directions of the departmental officers.
Construction of Embankment with approved Earth materials deposited at site and having on earth work excavation deposited on banks and foundation of otherb structures to meet the requirement including refilling consolidation, and all lead lift, Loading, Unloading, all labour, hire charge of all machineries, Transportation complete in all respects with all incidental charges and as per the directions of departmn[ent oficers/Enginner in charge of the work
Construction of Granular sub-base providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401 ,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work.
Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) -150mm compacted thickness by providing,laying,paving and compacting of aggregate gradtion satisfying table 400-13 of MORTH and satisfying the physical parameters as per MORTH table 400-12, mixing in wet mix plant 200 tonne capacity at OMC, carriage of mixed material to work site and laid in pavers to the required line and grade as per the drawing and compacted with vibrator rollers 8-10 tonnee to achieve the desired density 98% of maximum dry density. The rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision
Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.
Providing and laying plain cement concrete 1 : 4 : 8 ratio of (1 cement , 4 Msand and 8 graded stone aggregate 40mm nominal size) in foundation and basement including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification.
Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls. The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and spraying the same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers.
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items.
Below Plinth Beam
In Ground floor
In First floor
In Second floor
In Third floor
In Fourth floor
In Terrace floor
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc.
For Plane surfaces such as RCC floor slab, roof slab, beams, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square rcc columns, sunshades, Sill & Lintel top and bottom slab of rcc boxing, etc.
Supplying, fabricating and fixing in position of steel Fe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supply and constructing Fly ash Brick masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure using Fly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
In Foundation and Basement
In Ground Floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
In Terrace Floor
Precast Concrete Block masonry using Autoclaved Cellular Aerated Concrete Block of size 600x200x100mm conforming to IS 2185 (Part 3) : 1984 with Self Curing AAC Joint Mortar for Partition Wall of non load bearing type in accordance with IS 6041:1985 including neat finishing, etc., complete complying with standard specification and as directed by the departmental officers.
Ground floor
In First floor
In Second floor
In Third floor
In Fourth Floor
In Terrace Floor
Providing Polymer Coating ( Water Proof Coating ) for basement portion & toilet sunken portion with following specification and the surface shall be cleaned to remove all dust,foregin,matters lose matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio asper recommendation of the supplier. the mix shall be stirred thoroughly until no bubbles remain in the mix. any lumps found in mix shall be removed. apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. after drying,second coat shall be applied on the first coat as directed by the departmental officers etc. the rate inclusive of cost of materials and labour etc., complete
Foamed PVC Door frame : Specification: Providing factory made Pre Laminated FPVC Door Frame of the size 105 X 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre jointed with 6nos of 5mm long screw. The door frame shall be fixed to the wall by using 80 mm long screws through the frame frame with the help of PVC Fasteners of 3 nos. to be provided for Each vertical member, GI stiffners of ( U channel of size 29 X 9, 1mm, 150mm long) - 3 Nos at hinge point, Frame Reinforcement of (U' GI channel of size 46 X 22 X 0.6mm), bottom tie rod of ('U' GI channel Size of 15 X 15 X 1mm ), etc., Complete complying with the standard Specification. the door frame should be got approved from the Executive before use on work
Providing of 35mm thick factory made pre - laminated ABS ( Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent desings consisting of all round frame made out of water proof solid PVC bar of size 20 X 32 mm reinforced by 32 X 32 mm 2 nos ., for vertical made out of LVL core material of 32 mm thick high density craft paper honey comb board, sandwiched on both sides with pre- laminated ABS sheets thickness of 1.5mm PVC edge bending of size 0.45mm on the vertical sides. hardware made out of steels coated butterfly hinges - 3nos for Each shutter and ISI make SS round lock Complete complying with the standadrd Specification . the door shutter and frame should be got approved from the Departmental Engineer before on use
Supply and Fixing of Openable glass door 13.25mm thk the rate inclusive of conveyance to site. Rate to include all materials, labour charges, transportation charges, loading, unloading, scaffolding, staging, complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Supply and Fixing of Fixed glass 13.25mm thk in front entrance area the rate inclusive of conveyance to site Rate to include all materials, labour charges, transportation charges, loading, unloading, scaffolding, staging, complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge
UPVC Window Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. All the material used in the construction are approved Brand /reputed Brand as per agreement condition.
UPVC Ventilator Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi hambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.
Providing and fixing welded M.S. grills to the window openings,along the details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Client / Engineer-in-charge.
Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supplying and laying of Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. (Including Skirting work)
Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colour with base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and laying with best quality the following materials of Machine Polished granite slab of 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge
Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer's specification after entire completion of laying pipes, sanitary fittings etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge. i)
Including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturer's specifications and as directed.
Supplying and laying of Top of roof with Solar refelective tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of fine river sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand) according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. The rate including cost of all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Plastering 12 mm thick for external surfaces with cement mortar 1:5 (1 of cement : 5 of fine river sand) water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer's Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colourof synthetic enamel paint over the priming coat in all floors excluding cost of priming coatetc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supply and painting in ceilings with 2 or more coats of first quality water proof cement paint of approved make and colour over one coat of priming coat white colour water proof cement paint. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportation charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the departmental officers.
Supply and painting of two coats of Acrylic emulsion cement paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. The rate including cost of all materials, brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.(Internal surface)
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Providing and applying Brick textured paint one primer coat & 2 coats finished with approved texture & shade and colour for external walls. of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade tubular supports made of 304 L Grade stainless steel pipe of 25mm of 1.60mm thick welded to the railing. The supports will be grouted on the wall and provided with 93.00mm thick stainless steel circular base plaste of 304 Grade. The rate shall included for grouting into concerete with necessary supporting arrangement the hand rail in floor polishing buffing, cutting, grinding, conveyance, welding charges, electrical, charges etc. complete
Supplying and laying of 83 mm thick Rubber Moulded Hydraulic pressed Cement Concrete Paver Block over the sand filling and compacted with power rammer. The rate includes cost of paver block, cost of sand, labour charges for laying, hire charges for power rammer, transportation, loading and unloading etc. complete and as directed by the Departmental Officers.
ELEVATION
Supply and fixing of Elevation Aluminium Louvers including power coating including proper supporting we have considered powder coated aluminium vertical louvers using Jindal/equivalent 50mm X 50mm X 1.5mm thick section for vertical trellis (50mm section clear gap) with necessary hardwares etc.,
METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following: 1. V-6 Police Station & Fire Station Nermai Nagar- kolathur text in Tamil of size 2'0" x 15' with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required.
METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following: 1. V-6 Police Station & Fire Station Nermai Nagar- kolathur text in Tamil of size 2'0" x 15' with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required.
PLUMBING
The work shall include cutting making of walls and floors etc. The rates quoted shall include cost of necessary consumables like brass screws, CP extension nipple of approved make, dia and length, wooden plugs, white cement, sealants etc. Only drilling machines shall be used for making the holes in the walls for fixing, no wall jumper and hammer will be allowed.
PART-A ( SANITARY FIXTURES & CP FITTINGS )
Supply and fixing in position white European Water Closet (single piece or wall mounted) of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directed by the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.(Make Parryware Claret Rimless Single Piece Suite S220 C8640 or Equivalent
Supplying and fixing the best quality approved make of bip cock with C.P. health faucet Hindware make (F160001) wall hook one metre long flexible tube, angle cock with wall flange including cutting and making good the walls wherever required etc.complete, complying with standard specification and as directed by the Department officers. The quality and make of health faucet should be got approved by Executive Engineer before use on work.
Supplying and fixing in position Indian water closet of size 580 x 440mm, glazed earthern ware of approved quality and colour with 'P' trap or 'S' trap confirming to IS:2556-part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One of Lime, Two of Sand, Five of Brick jelly) 100mm thick and by dismantling brick masonry, reinforced finishing to the required slope and including giving necessary connection to PVC soil pipes cement concrete roof / floor slab and making good the disturbed portion to origional condition without leakage etc., complete complying with standard specification and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works)
Supplying & fixing approved make, 15 mm dia SS of bib tap, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying & fixing approved make, Toilet Paper Holder, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying and fixing White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm dia GM Wheel Value, 15mm dia 'B' Class GI Waste Water Pipe, 15mm dia Nylon Connection, 15mm dia Brass Nipple, and suitable screws, shellac etc., complete. The rate including cost of all materials, labour charges for fixing and transportation etc. completed as directed by Engineer-in-Charge. (Make Jaguar URS-WHT-13253N or Equivalent)
Supplying and fixing of Oval Shape Wash Hand Basin of size 560 x 450mm, including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The Wash basin should be got approved by the Executive Engineer before use on works.
Supplying and fixing SS sink of size 1200 x 550 x 180mm, including fixing with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The SS Sink should be got approved by the Executive Engineer before use on works.
Supplying and fixing heavy duty 15mm CP shower unit comprising of CP 15mm dia hot & cold mixer with CP spout, overhead shower set comprising of CP shower arm, rose etc.,complete with CP wall flanges. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.
Supplying and fixing Brass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.
Supplying & fixing approved make, Coat Hook, conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got apprioved by the Engineer - In- charge before use on work.)
Supplying and fixing Brass Chromium Plated soap tray of size 150x150x50 mm. The rate including cost of soap tray, teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.
Automatic Electrical Water Heater with copper container, with Glass Wool / Puf Insulation with MS powder coated shell suitable for 25 Litres capacity 230V / 1000W (Higher End)
PART-B ( INTERNAL DRAINAGE & WATER Providing PIPES , FITTINGS & VALVES )
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below Stilt level .(Internal, External & Rain water system)
(Pipes Running inside the toilet & etc)
a) 75mm dia (6kg/sq.cm pressure rated - Type - B)
b)110mm dia (6kg/sq.cm pressure rated - Type - B)
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below Stilt level .(Internal, External & Rain water system)
a)40mm dia (10kg / sq.cm)
b)50mm dia (10kg / sq.cm)
Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three M sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR-11, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Internal)
20 mm dia
25 mm dia
32 mm dia
Supplying & fixing in position first quality & approved variety of Brass body nickel plated with stainless steel Ball Valves with I.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading of Pipes etc., complete complying with standard specifications for both internal & external water supply arrangements.
20 mm dia
25 mm dia
32 mm dia
50 mm dia
Supplying & fixing in position first quality & approved variety of Brass body nickel plated with stainless steel Butterfly Valves ( Heavy type ) with I.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading of Pipes etc., complete complying with standard specifications for both internal & external water supply arrangements.
65 mm dia
85 mm dia
Providing, installation, testing and commissioning approved make CI Y-type Strainer conforming to IS standard with necessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications.
32 mm nominal bore
80 mm nominal bore
Making through holes in Plain or Reinforced Cement Concrete with Diamond Core Drilling System by using BOSCH power tools of following diameter in 150mm thick toilet floor slab
Wall Cutout
75mm dia 150mm thick
100mm dia 150mm thick
FLOOR CUTOUT
200mm dia 150mm thick
PART-C ( EXTERNAL DRAINAGE & WATER Providing PIPES , FITTINGS & VALVES )
Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.
(Pipes Running in the Shaft & below ground level)
a) 75mm dia (6kg/sq.cm pressure rated - Type - B)
b)110mm dia (6kg/sq.cm pressure rated - Type - B)
c)160mm dia (6kg/sq.cm pressure rated - Type - B)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR-11, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Shaft,Terrace & External Pipes)
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Supplying, laying and jointing UPVC SCH-80 pipes of approved quality and best variety conforming to ISS and with ISI mark of the following size including cutting, threading and fixing UPVC specials but excluding cost of such specials and fixing to wall with necessary teak wood plugs, GI clamps and screws, making good the dismantled portions to original condition with necesscary brick work and plastering wherever necessary scaffolding charges above ground level upto 4 m height.
65 mm dia
80 mm dia
Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).
Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mm thick M.S. plate of size 300 x 300mm plus dia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.
32 mm dia
40 mm dia
65 mm dia
80 mm dia
110 mm dia
Supplying & fixing in position 150 X 100 mm square mouth 'P' or 'S' trap stone ware Gully trap 'A' grade with cast iron double gratings of size 150 X 150 mm with C.I. air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineer before use on works ).
Constructing solid block masonry manhole 600 x 600mm INTERNAL SIZE & 600mm to 1000mm deep in cement mortar 1:3( 1 Cement: 3 M.sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mix for base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete
Constructing solid block masonry manhole 1200 x 900mm INTERNAL SIZE & 1500mm to 2100mm deep in cement mortar 1:3( 1 Cement: 3 M.sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mix for base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm)
PART-IV STORM WATER DRAIN PIPES & FITTINGS
b)110mm dia (4kg/sq.cm pressure rated - Type - A)
Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,.
Providing & fixing of PVC baby nahani trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm, connecting to balcony rain water pipe, complete including cutting and making good the walls and floors.
Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration.
Bore hole of 160 mm dia from the bottom of percolation pit for a depth of 6m from the bottom of percolation pit drilled by using auger manually.
Bore hole to be filled with medium sized pebbles to provide meehamical strength to the holes and enhance infiltration.
Rate quoted shall be inclusive of earthwosk excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.
PART-V PUMPS AND ACCESSORIES
DOMESTIC WATER BOOSTER PUMP
IMPORTANT NOTES:
Vendor has to visit the site and study the existing system Underground sump location. Technical data sheet & pump GA drawing has to be submit to Consultant/Architect and has to be get concurrence. Till commissioning has to be borne by vendor.
Supply , fixing and commissioning of Hydropneumatic pumps (1 working and 1 standby) Vertical in line or Submerged type with Single VFD for pumping the water from underground sump to distribution header running buried underground level through hydropneumatic pressure vessel for domestic purposes. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts and nuts.
The pump shall be suitable for the following requirements:
Flow rate of Each pump - 12.0 Cu.m/hr
Pump design head -31 m
Pump to be fitted with one VFD
The pumps shall be provided with:
2 Nos. Pressure switch with caliberation.(if required)
1 no. pressure gauge 4" dial with needle valve tee and fittings.
2nos. cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 20 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, GI washers, and neoprene rubber gaskets Complete etc., (inter valve / audco make) on the delivery side
2 nos. cast iron lever operated slim seal type butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 20 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, GI washers, and neoprene rubber gaskets Complete etc., (inter valve / audco make) on the Suction Side. If it is submerged type Suction side valve not requried.
2 Nos. slimseal flap type check valve with CI body and cast steel disc pressure rating PN-20 Kg / sq.cm including a set of GI flanges as per BS-10 table 1 including bolt nuts, GI washers, and neoprene rubber gaskets Complete etc., (inter valve / audco make) on the delivery side.
GI manifold of suitable dia on delivery side and suction side finished neatly with hot dip galvanizing to 100 microns with flanged end on either sides and collar provision for connectivity of above mentioned valves. If it is submerged type Suction side manifold not requried.
Automatic Booster card for automatic start and stop of pumps and sequencing of the entire system
Micro processor based Built - in electrical control panel with motor starter relays, single phase preventor, dry run protection, indicating lamps, ON - OFF push buttons, alarm indication with signal in the event of pump failure, etc., and shall be suitable for 415 +/- 10% volts & 50Hz electric supply.
TERRACE FLOOR
Installation, Testing & commissioning of approved make submersible Clearwater lifting pump set with suitable horse power motor to Each pump to discharge with control panel & all necessary accessories, conducting trail run, providing necessary civil foundations and base frame with all accessories like pressure gauge, control valve etc., and consumables, maintaining the system for the period of one year. Rate shall include all Electrical panel work connected to existing Electrical cable arrangement, etc. complete. Incoming Electrical cable to starter panel will be under scope of Electricalwork. (Transfer of water from UG Sump to Over Head Water Tank.)
Flow : 6000 Litere/hour Head : 36 MWC No. of pumps : 2 (1 working + 1 Standby) Type : Submersible Application : Clear water transfer Time : 2.0 Hours
GROUND FLOOR
BORE WELL
Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor's rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. following references from SR-TWAD Board
Reaming from 200mm dia pilot bore upto 350mm dia bore as direct by the Engineer incharge up to 80mtr depth ending below ground level.
Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992
200mm dia CS
200mm dia RS
150mm dia RS
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.
200mm dia CS
200mm dia RS
150mm dia RS
Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock. (As per Quotation) upto 30m rock level
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method.
Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.
ELECTRICAL
LT CT TNEB METER BOX: CT Metering Panel - Supply, installation, testing and commisioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for Each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS channels, fasteners, etc., including all associated control wiring. 1set of 250/5A CT with TNEB Metering provision and 1nos of 250/5A CT for APFCR.
250A Isolator Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of 250A TPN MCCB panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for Each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, (As per quotation)
MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 250Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings: EB Incomer : 1 No. 250Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOM DG Incomer: 1 No. 250Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOM Common C/O Incomer: 1 No. 250Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lamps Metering : 2 Set of RYB LED Indication lamps 2 Nos. of Multifunction Meter with RS 485 2 Set of Current Tranformers (250/5A, Cl-1), 1 No. 250/5A CT for APFCR 2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 2 Nos. 100A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR & Spare) 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (GF & FF AC, SPARE), 10 Nos. 32Amps DP MCBs (PDB-1&2, GF LDB-1&2, FF LDB-1&2, UPS, Ex.LDB, LIFT, SPARE)
Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 24 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. i.63A 4P MCB - 1 no. ii.63A 4P 30MA RCCB/ELCB - 1 no. iii.63A DP MCB Isolator -3 nos. iv.6A to 32A SP MCB - 24 nos. (SD629 / Pg 273)
Supply and fixing of 7 segment 6 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 24 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. i.32/63A 4P MCB - 1 no. ii.32/63A 4P 30MA RCCB/ELCB - 1 no. iii.32/63A DP MCB Isolator -3 nos. iv.6A to 32A SP MCB - 18 nos. (SD628 / Pg 273)
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 6 nos. 32A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and Laying of 3 1/2 x 120 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 4 x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Clamping of 3 1/2 core x 50 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. (SD 202 / Pg 82)
Supply and Clamping of 3 1/2 core x 25 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland for 4 x 10 Sq.mm PVC LTUG armoured cable with earth connection
Supply and fixing of brass cable gland for 3-1/2 x 50sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 4 x 10 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (SD 213 / Pg 86)
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position.
Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour.
Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion with suitable
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End - PRIMARY POINTS
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End - SECONDARY POINTS
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug)
LED LIGHTINGS
Supply, fixing, testing & commissioning of 18W LED ceiling Recess mounted - indoor luminaire with soft & uniform light distribution. Dimension : ⌀148mm X 50mm.Luminaire made of die-cast aluminium for better thermal management. Luminaire body finish with White expoxy polyster Powder Coated. High efficiency diffuser (Opal High Transimssion Diffuser) for glare free, uniform light distribution. Luminaire integrated with constant current LED driver. Cable entries for through-wiring of mains supply cable Prewired with LED driver and suitable for operation on 240V, 50Hz single phase ac supply. Operating voltage range (90 - 265V AC). LED driver efficiency should be greater than 83% with CRI greater than 80 and with colour temperature 4000K range. LED having 50,000 burning hours with minimum 70% lumen maintenance and power factor > 0.9, UGR < 19 complaince to LG7 guidelines. SDCM≤3. System consumption should be 18W LED fixture with lumen package of 1835 lumens (100 lm/W). The luminaire shall be wired with PVC unsheathed copper leads from terminal to the fitting. Luminaire should have NABL Certificate on Resitance to Flame & Ignition as per IS 10322 Part-1:2014. Mandatory CE Marking & BIS Certified. Make: K-LiTE (Model No. 3322).
Supply, fixing, testing & commissioning of 22W LED ceiling surface mounted - indoor luminaire with soft & uniform light distribution. Dimension : ⌀177mm X 43mm. Luminaire made of die-cast aluminium for better thermal management. Luminaire body finish with White expoxy polyster Powder Coated. High efficiency diffuser for glare free, uniform light distribution. Luminaire assembly integrated with constant current LED driver. Cable entries for through-wiring of mains supply cable Prewired with LED driver and suitable for operation on 240V, 50Hz single phase ac supply. Operating voltage range (90 - 265V AC). LED driver efficiency should be greater than 85% with CRI greater than 80 and with colour temperature 4000K range. LED having 54,000 burning hours with minimum 70% lumen maintenance and power factor > 0.9 with THD less than 10% & UGR < 19 complaince to LG7 guidelines. SDCM≤3. System consumption should be 22W LED fixture with lumen package of 2497 lumens (110 lm/W). The luminaire shall be wired with PVC unsheathed copper leads from terminal to the fitting. Luminaire should have NABL Certificate on Resitance to Flame & Ignition as per IS 10322 Part-1:2014. Make: K-LiTE (Model No. 3613)
Supply, installation, testing and commissioning of 40 W LED tube light fitting with cool day light made out of CRCA powder coated body, poly methyl meth acrylate (PMMA) diffuser, glare free light, Suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.
Supply, fixing, testing & commissioning of 60W Designer Hanging Chandelier Light Suspended LED luminaire (multiple light sources at the end of metal rod). Light colour temperature 3000K range. LED more than 90% lumen maintenance with Surge protection. The luminaire shall be IP40 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014.
Supply, fixing, testing & commissioning of 16W Bollard with concrete pedestal luminaire designed for surface mounted. Symmetrical light distribution. Luminaire made of square extruded aluminium tube (grade 6063) with pressure die cast aluminium components of high corrosion resistance and non corrosive stainless steel fasteners. Clear polycarbonate diffuser. Pressure die cast aluminium mounting plate 121 square x 4mm thick with 3 elongated holes 15 x 10 to suit M8 bolts at PCD 70 with pure polyester powder coating.The base plate have a cable entry hole of 30mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 4-6KV. Luminaire dimension : 121mm square x 970mm height. CE & BIS Certified. Inhouse NABL accredited lab. KLite Model No. KL4728
Supply, fixing, testing & commissioning of 60W Juno-Column light luminaire designed for surface mounted. Shielded light distribution. Luminaire made of spun aluminium with extruded aluminium alloy (grade 6063) and non corrosive stainless steel fasteners. Translucent acrylic diffuser. Pressure die cast aluminium mounting plate 250mm dia round x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at CC 140 with pure polyester powder coating.The base plate have a cable entry hole of 65mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >88%, Power factor >0.95, THD <10%, Surge protection 6KV. Luminaire dimension : 600mm dia round x 4500mm height. CE & BIS Certified. Inhouse NABL accredited lab. KLite Model No. KL7034
Supplying, installation, testing and commissioning of 1200 mm (48") sweep AC ceiling fan complete with out modular type stepped electronic 300W regulator, with 1 metre down rod with all required accessories including point wiring ( 5 STAR
Supply and fixing of 450mm (18") AC Exhaust Fan 450mm (18”) Sweep (Light Duty) with necessary accessories and hardwares as required.
Supply and fixing of louvers shutters arrangements for 450mm (18") sweep AC exhaust fan
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supply and erection of Copper plate earthing station with GI pipe, 600x600x3mm thick copper plate, salt, charcoal, etc., including civil works, heavy duty CI Cover, etc., as per IS 3043 standards
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection
Supply and Run of 1 of No.8 SWG copper wire for earth connection
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fasteners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc.' Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements. The rate shall inclusive of necessary Wedge anchors threaded rods,nuts & bolts, making clamp for rcc roof fix / perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be provided at not more than 2 mtr center to center and as per site requirement )
Perforated type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300 mm width and 50mm height
Perforated type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150 mm width and 50mm height
Supply and fixing of Raceways Metal / GI with 150mm width x 38mm height with Suitable Fixing bracket and Siutable Coupler Jiont with Connected all accessories complete work.
Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above.
SAFETY ACCESSORIES
Supply and erection of '2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS (5 NOS)
Supply of First Aid Box complete with all First Aid Medicines
Supply and fixing of Shock Treatment chart with Glass frame
Supply and fixing of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle
Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms
Supply and fixing of Danger Boards (415Volts & 230Volts)
CCTV, VOICE & DATA SYSTEM
Supply, Installation, Testing and commissioning of 32 channel 2 SATA NVR, with 8TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support
upto 10TB capacity for Each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency,Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces.
Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification: ●1/2.5" Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection) ● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied ●On-board Storage - Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°,
●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. (Rate as per Quotation)
Supply, Installation, Testing and Commissioning of 55" smart LED TV with following specifications a) Full HD 4K monitor b) 2 Speakers, HDR, Dolby Vision c) HDMI -3nos d) USB -3nos e) Wifi, Ethernet f) 16GB storage
Supply and Clamping of CAT 6 unarmoured cable in suitable PVC Pipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges.
Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK)
Supply and fixing of POE 24 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK)
Supply and Fixing of Rack with Accessories -Higher end 9u Rack with fan extra for the above rack. (speaker/data/cctv)
Supply and Fixing of Rack with Accessories -Higher end 4u Rack for the above rack. (speaker/data/cctv)
7.5KVA UPS Supply, erection, testing and commissioning of the following rating of UPS Systems for emergency lightings. Supply of Micro Processor Controlled 10 KVA UPS and input supply of 430 Volts ± 15%, 3 Phase, 50 Hz ± 5% and an out put of 230 Volts ±1%, 1 Phase 50 ± 0.01 Hz consisting of Rectifier, Out put Isolation Transformer, Battery Circuit Breaker, Static and Manual Bypass Switches and all others accessories required as per detailed specification .The system should be suitable for independent mode of operation.Supply of Sealed Maintenance Free Batteries to support 10 KVA for 6 hrs complete with intercell connectors, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries as per specification.Installation,Testing and Commissioning of complete 1 nos 10 KVA UPS system in Independent mode of operation with the battery bank including inter connection of UPS and battery banks with adequate size of copper cable, lugs etc. complete as required.
Supply, Erection of 6m Length pole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.
PA SYSTEM
Supply, Installation,Testing & commisioning of 240 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 watts RMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of 2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.
Supply, run, testing and commissioning of 2Core x 1.5sq sqmm PVC insulated UnArmoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Lift Shaft Wiring : Wiring, Connecting, Testing & Commissioning for lift well light point and 6Amps power socket outlet for all 4 floors with 2 x 2.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V grade along with 1 x 2.5 sqmm FRLS PVC insulated standed copper conductor cable as earth wire in suitable PVC rigid pipe on wall and ceiling with PVC accessories , 2 Nos. of 5A single way module switch (for controlling light point and socket Outlet ) for Each floor of the lift well , with bulkhead lamp 1 No. 5A 5 Pin shuttered socket outlet with flush type switch for Each floor of the lift well and making necessary connections complete etc.
LIFT Inspection Drawing Approval Charges Charges
DIESEL GENERATOR WORKS
DG SET Supply, Erection, Testing and Commissioning of 250KVA Diesel Generator set with AMF control panel, comprising of Water cooled CPCB developing @ 1500 RPM and Alternator, complete with type approved canopy and all accessories. with the following technical specification: *Industries most reliable engines, proven over decades. *Low emission, High efficiency. *Compact, robust and rugged design. *Engine Dry type air cleaner *Exhaust Silencer (Residential type) Hospital Grade. *Expansion bellow *Lube oil cooler Lube oil filter (“Spin-on” type) *Fuel Filter (“Spin-on” type) *In line mono block fuel injection pump with Electronic Governor and fuel feed pump. *Dynamically balanced Flywheel with starter ring *Electronic Governor :Governing class G2(as per ISO 8528 part V) *SAE 1 flywheel housing and flywheel suitable for SAE 14 disc coupling for close coupling of single bearing alternator.
*Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR 200KVA, Three phase 415V, 0.8 pf 4 wires 50 hz at 1500 RPM brushless alternator. The voltage regulation will be 2 phase sensing +/¬ 1 %. The alternators shall be of Class H insulation, enclosure IP 23 and are designed built and tested to IS 4722 or any other equivalent Indian or international standards. Control Panel: 200 KVA DG Set Std Control Panel Consisting of EMS KG934 unit consisting Volt, Amps, RPM, Hz, LLOP, HWT, Low fuel
level, over Speed alarm, Over Load alarm, Load imbalance safety alarm, etc. Fuel Tank: 300 Letters Capacity inbuilt Fuel Consumption: 100% = 37.6 Litres/hr.75% = 27.6Litres / hr.50% = 19.8Litrs/hr. Battery: 24V DC, 130AH Supply of AMF Control Panel Suitable for 160 KVA DG set for EB Services with byepass arrangement. (Make: Kirlosker, Koel or equvalent) including Suitable Foundation and Transportation charges.
HAVC Work (Split Units)
1.5 TR Split Type AC Unit - 5 Star Rated M-1984
2.0 TR Split Type AC Unit - 5 Star Rated M-1985
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay M-1988
Supply and fixing of MS stand for fixing outdoor unit M-1991
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) M-1990
SOLAR PANEL
SOLAR PV PLANT On Grid Solar PV Plant comprising of: i) Solar panels of type Mono Crystline, PERC, etc. ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories. iii) D.C. D.B iv) A.C. D.B v) A.C. cables and accessories vi) Lightning arrestor, earthing, etc. vii) Module Metallic Mounting Structures viii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements For 20KWp
Supplying and Fixing of 13 Persons Passenger Lift (2000mmx1100mm) Gearless Lift without Machine Room for (G + 4) Floor As Per SR Page No 230 M-2370 Passenger Lift MRL, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & , fuels, fixing in position at all levels, heights, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. M-2370
kadal constructions (BID ID -1397333)
PONKULALI AND CO (BID ID -1397845)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.pdf
Tender Documents • 0.32 MB
BOQ.xls
BOQ • 0.53 MB
Tenderdocument_2.pdf
Tender Documents • 2.65 MB
Download all tender documents and submit your bid