Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
3 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
POWER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. As detailed in Para 10.2 of Tender Form (Second sheet) of Part 1 of attached GCC-2022.
FOR ALL TYPE FIRM AND ALL VALUE OT TENDER: The contractor should have valid Electrical contractor license issued by Govt. and submit along with tender document.
Experience in similar nature of work:- The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. As detailed in Para 10.1 of Tender Form ( Second sheet) of Part 1 of attached GCC-2022. DEFINATION OF SIMILAR NATURE OF WORK FOR THIS TENDER: Any electrical work related to HT/LT installation.
23 conditions · 6 needing a document upload
Tender document and all the uploaded supporting documents must be digitally signed by the authorized signatory for tender, in token of their acceptance.
DOCUMENT REQUIRED FOR Sole ProprietorshipFirm : All documents in terms of Para 10 of theTender Form (Second Sheet) of GCC APRIL-2022with including correction slip upto date.
DOCUMENT REQUIRED FOR HUF : (I) A copy ofnotarized affidavit on Stamp Paper declaring thathe who is submitting the tender on behalf of HUFis in the position of 'Karta' of Hindu UndividedFamily (HUF) and he has the authority, powerand consent given by other members to act onbehalf of HUF. (II) All other documents in termsof Para 10 of the Tender Form (Second Sheet) ofGCC APRIL-2022 with including correction slipupto date
DOCUMENT REQUIRED FOR Partnership Firm: Alldocuments as mentioned in para 18 of the TenderForm (Second Sheet)of GCC APRIL-2022 withincluding correction slip upto date
DOCUMENT REQUIRED FOR Company registeredunder Companies Act2013 : (i) The copies ofMOA (Memorandum of Association) / AOA(Articles of Association) of the company. (ii) Acopy of Certificate of Incorporation (iii) A copy ofAuthorization/Power of Attorney issued by theCompany (backed by the resolution of Board ofDirectors) in favour of the individual to sign thetender on behalf of the company and createliability against the company. (iv) All otherdocuments in terms Para 10 of the Tender Form(Second Sheet) of GCC APRIL- 2022 with allcorrection slip
DOCUMENT REQUIRED FOR LLP (Limited LiabilityPartnership): (i) A copy of LLP Agreement (ii) Acopy of Certificate of Incorporation (iii) A copy ofPower of Attorney/Authorization issued by theLLP in favour of the individual to sign the tenderon behalf of the LLP and create liability againstthe LLP. (iv) An undertaking by all partners of theLLP that they are not blacklisted or debarred byRailways or any other Ministry / Department ofthe Govt. of India from participation in tenders /contracts as on the date of submission of bids,either in their individual capacity or in anyfirm/LLP or JV in which they were / arepartners/members. Concealment / wronginformation in regard to above shall make thecontract liable for determination under Clause 62of the Standard General Conditions of Contract.(v) All other documents in terms of Para 10 ofthe Tender Form (Second Sheet)of GCC APRIL-2022 with including correction slip upto date
DOCUMENT REQUIRED FOR Registered Society &Registered Trust :(i) A copy of Certificate ofRegistration (ii) A copy of Memorandum ofAssociation of Society/Trust Deed (iii) A copy ofPower of Attorney in favour of the individual tosign the tender documents and create liability No No Allowed(Mandatory) against the Society/Trust. (iv) A copy of Rules &Regulations of the Society (v) All otherdocuments in terms of Para 10 of the TenderForm (Second Sheet)of GCC APRIL-2022 withincluding correction slip upto date
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JP- Electrical work in connection with [1] Raising the level of PF to high level at BWL & HSI and extension of length of PF at BWL,HSI & GLNA stations .Provision of FOB at KVGM halt station, [2] Raising the level of PF to high level at PSL, MJNL , GAL & KNAR halt and extension of length of PF to 600 meters at BU ,KNAR & SRRG stations, [3] Raising the level of PF to high level at Bassi (BAI) , Bansko(BSKO), Khandel (KNDL) & Peepli Ka Bas (PKBS) stations, [4] Raising the level of PF to high level at JHIR,JW ,KUT ,BAK & ARNA and provision of FOB at JHIR & JW stations
EL-JP-17-2026-27
EL-JP-17-2026-27
Open
Works - General
12 Months
Jaipur, Rajasthan
₹0
₹3.2 L
3 Aug 2026
10 Jul 2026
20 Jul 2026
107 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,59,96,622.68 | ||
| — | 202.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR) as per spec | — | — | — | 75,127.84 | |
| — | 166.00 | — | — | ||
| Supply and fixing 5/6A plug 5-pin 230V with switch, board and wiring with 2.5sqmm PVC CU cable as per spec. | — | — | — | 31,835.48 | |
| — | 41.00 | — | — | ||
| Supply and fixing 15/16A power socket with switch on flush type sheet metal box and connection as per spec | — | — | — | 7,821.98 | |
| — | 16.00 | — | — | ||
| Supply and fixing 12 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 4,075.2 | |
| — | 36.00 | — | — | ||
| Supply and fixing 8 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 8,325 | |
| — | 26.00 | — | — | ||
| Supply and fixing 6 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 4,281.16 | |
| — | 16.00 | — | — | ||
| Supply and fixing 4 module plate for fixing of switches and sheet metal box of good quality concealed fixing of MS/PVC | — | — | — | 2,069.76 | |
| — | 1160.00 | — | — | ||
| Wiring of sub-main with 2x2.5 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 84,355.2 | |
| — | 430.00 | — | — | ||
| Wiring of sub-main with 2x4 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 57,585.6 | |
| — | 230.00 | — | — | ||
| Wiring of sub-main with 2x6 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec | — | — | — | 30,987.9 | |
| — | 570.00 | — | — | ||
| Wiring of shed LP/TP in covered shed with 1.5sqmm copper wire PVC insulated & multi-stranded in PVC conduit, ISI mark 1.5mm thick, size 19/20mm dia and 1.5sqmm PVC insulated multi stranded copper earth wire with ceiling rose fixed with saddles or tied properly and junction box as per spec. | — | — | — | 1,15,094.4 | |
| — | 990.00 | — | — | ||
| Supply and fixing casing caping of PVC size 75x75mm and 2mm thick with suitable nut bolts for fixing or tied with copper wire 14swg for 5/7 nos. of copper wire & earth wire as per spec. | — | — | — | 1,35,936.9 | |
| — | 990.00 | — | — | ||
| Supply, laying and fixing five wire of PVC copper cable size 10sqmm flame retardant, low smoke single core insulated un sheathed multi-stranded copper conductor, voltage grade 1.1 KV (1100 v) conf to IS694-1990 or latest in five with one no 8 SWG copper earth wire as per spec. | — | — | — | 5,43,767.4 | |
| — | 990.00 | — | — | ||
| Supply and provide MS flat of iron size 40x3mm with spacers and fixing clamps as per spec | — | — | — | 1,49,539.5 | |
| — | 1499.00 | — | — | ||
| Fixing of LED light fitting with PVC insulated, multi-stranded copper wire for connection as per site requirement as per spec | — | — | — | 1,12,320.07 | |
| — | 98.00 | — | — | ||
| Fixing of ceiling fan with clamp, hooks and down rod as per requirement and connection as per spec | — | — | — | 22,351.84 | |
| — | 22.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A, Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec | — | — | — | 76,118.9 | |
| — | 22.00 | — | — | ||
| Supply, fixing, testing and commissioning of Distribution Board double door, 3-phase and neutral with incoming 63A 4-pole MCB and outgoing 12Nos. MCB 6-32A single pole as per spec. | — | — | — | 1,15,527.28 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A, double pole, 30mA with Earth leakage, overload and short circuit protection as per spec | — | — | — | 57,923.75 | |
| — | 23.00 | — | — | ||
| Supply, fixing, testing and connecting of Distribution Board with incoming 32A, single phase, DP MCB and outgoing 8Nos. single pole MCB 6-16A as per spec | — | — | — | 68,864.99 | |
| — | 12.00 | — | — | ||
| Supply, testing and commissioning of LT distribution panel 2x250A MCCB incoming and 4x100A MCCB with A&V meter selector switch indications etc as per spec | — | — | — | 8,82,373.56 | |
| — | 16.00 | — | — | ||
| Supply and fixing of Metal Clad Plug Socket 20A single phase with 32A MCB including fixing and sheet metal enclosure box with one 20A plug top (Ray roll type) to be supplied with board as per spec. | — | — | — | 12,394.56 | |
| — | 218.00 | — | — | ||
| Supply and Providing GI Pipe Earthing of 4meter length as per spec | — | — | — | 4,20,216.8 | |
| — | 329.00 | — | — | ||
| Supply and fixing of octagonal pole 5meter long, Hot dip galvanized with foundation, base plate with fixing of 1No. arms 1000mm for the fittings including smart pack junction box with 6A MCB and terminals as per spec. | — | — | — | 29,22,125.36 | |
| — | 4720.00 | — | — | ||
| Supply and laying of Electrical copper cable 2.5 sqmm/ 3 core | — | — | — | 3,94,969.6 | |
| — | 357.00 | — | — | ||
| Dismantling of existing LT/HT poles with fittings by digging the foundation and transportation up to required site as per spec | — | — | — | 1,85,650.71 | |
| — | 165.00 | — | — | ||
| Installation, Erection of 5/6 meter long Octagonal pole with Foundation as per spec | — | — | — | 3,16,941.9 | |
| — | 23.00 | — | — | ||
| Supply, fixing testing and commissioning of Astronomical timer multifunctional digital as per spec | — | — | — | 2,43,056.64 | |
| — | 416.00 | — | — | ||
| Supply and fixing of glow sign boards having train timing or utility signage with flex star/hanwa 19 onze solvent multicolour printing, ISI LED tube light per 5sqft; 30gauges GI sheet on all four sides; 1"x1" sq steel tube & angle frame with red oxide, including transportation, labour charge, angle fittings charges for all boards as per spec | — | — | — | 88,266.88 | |
| — | 32580.00 | — | — | ||
| Laying of LT/HT Cable IN AIR / Pipe/ Wall/tray as per spec | — | — | — | 7,21,647 | |
| — | 22900.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995 50mm dia wall thickness 3 mm PN-6 under the road/air. The work invloves laying of HDPE pipe. | — | — | — | 24,21,904 | |
| — | 1800.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 75/80mm dia wall thickness 3 mm PN-4 under the road/air. The work invloves laying of HDPE pipe. | — | — | — | 1,93,122 | |
| — | 22900.00 | — | — | ||
| Digging and filling of trench size 0.4x1.2 mtr as per spec (trench work may be on kuchha/pucca and land and all type of soil as per site requirement and without protective layer of brick) surface of trench shall be made good in all respect and satisfaction of site engineer | — | — | — | 10,13,325 | |
| — | 1390.00 | — | — | ||
| Horizontal Directional Drilling (HDD)/Boring and trenchless cabling. Supply, transportation and insertion of self lubricated HDPE pipe and laying of cables in boring under the track /road /ground/ masonary building by using self lubricated HDPE pipe of 120mm outer dia and 103.5mm inner dia in the bore and laying of cables in the bore under the track/road/ground/masonary building. The depth of horizontal boring should be minimum 1 mtr from rail flange/road level/ground, as per site requirement. | — | — | — | 17,92,641.3 | |
| — | 45.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mm thick size 600x300x600mm with suitable MS stand Copper bus bar of 200A capacity and 2x63A MCB 4 pole as per spec | — | — | — | 2,10,982.95 | |
| — | 2.00 | — | — | ||
| Supply and erection of LT junction box for AT as per Spec.( for 10/25KVA AT) | — | — | — | 36,752.04 | |
| — | 4.00 | — | — | ||
| LT CABLE STRAIGHT JOINT: Supply, installation, testing and commissioning of heat shrinkable straight through joint with required accessories complete in all respect suitable for LT cable, 25-185mmsq cable as per site requirement. | — | — | — | 6,427.44 | |
| — | 4.00 | — | — | ||
| Transportation, installation, testing and commissioning of water cooler including with water connection angle valve as per spec | — | — | — | 11,277.8 | |
| — | 1.00 | — | — | ||
| Dismentaling and relocation , foundation, installation, Testing & commissioning of 40 kWp Solar plant with accesories as per spec. | — | — | — | 4,60,800 | |
| — | 186.00 | — | — | ||
| Supply and fixing of octagonal pole 5meter long, Hot dip galvanized with foundation, base plate with fixing of 2Nos. arms 1000mm for the fittings including smart pack junction box with 6A MCB and terminals as per spec. | — | — | — | 16,79,306.58 | |
| — | 100.00 | — | — | ||
| Supply and fixing of GI pipe 50 mm dia B class with flange for delivery with flanges, clamps, nut-bolts etc as per spec. | — | — | — | 31,989 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and connecting of Distribution Board with incoming 32A, single phase, DP MCB and outgoing 4Nos. single pole MCB 6-16A as per spec | — | — | — | 2,128.44 | |
| — | 2.00 | — | — | ||
| Supply of 5 HP/3.7kW, Single phase submersible pump set with control panel , Head Range (M); 100 or above, Discharge (LPM); 50 or above , stage 10 or above, make Kirloskar KS4E05020 with starter panel as per spec | — | — | — | 79,804.9 | |
| — | 2.00 | — | — | ||
| Supply of sub. Mono block Pumps 5HP, 415V complete with accessories at site Model KSB MR 5 HH SD or similar model of other approved make as per spec. | — | — | — | 37,613.8 | |
| — | 1.00 | — | — | ||
| Installation of pump set with GI pipe, nut, bolts, washer, rubber packing, valve, copper cable etc as per spec | — | — | — | 4,814.74 | |
| — | 1.00 | — | — | ||
| Supply and fixing pipe fittings bends sockets flanges, delivery valve and non return valve and supporting clamps (2 sets) etc. as per spec | — | — | — | 5,592.48 | |
| — | 50.00 | — | — | ||
| Supply and laying of copper flat cable size 3x6sqmm as per spec | — | — | — | 5,583.5 | |
| — | 1.00 | — | — | ||
| Supply fabrication fixing and installation of MS sheet steel enclosure free standing outdoor type with heat dissipation sides 2feet above ground level for control panel and accessories of 16swg sheet size 120x70x60cms with painting and locking arrangement and foundation with installation of automatic control panel inside the box as per spec. | — | — | — | 12,817.7 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of 40A MCCB 4 pole as per spec | — | — | — | 8,373.89 | |
| — | 1.00 | — | — | ||
| Provision of capacitor 5KVAR as per spec | — | — | — | 6,835.71 | |
| — | 1.00 | — | — | ||
| Supply and installation of automatic control panel with DOL starter for 3HP to 5HP three phase pump including connections and providing cable from main board to control panel and connection for WLC in bore well as per spec | — | — | — | 13,395.45 | |
| — | 8.00 | — | — | ||
| Supply and Providing Copper Plate Earthing 4meter deep, copper plate size 600x600x3mm as per spec. | — | — | — | 47,157.6 | |
| — | 80.00 | — | — | ||
| Supply and fixing of Copper Earth Flat strip size 25x3mm as per spec | — | — | — | 22,423.2 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
Advance Correction Slip No 1 to 11
ATTACHMENT
ESTD-17-2026-27.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
AdvanceCorrectionSlipNo1to11GCC-2022_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .