CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
COMPREHENSIVE MAINT/REPAIR/IMPV OF E and M INSTALLATIONS INCL SECURITY LIGHT, POLE BOXES, PROTECTION PIPE AND TIMERS ETC AND ALLIED WORKS UNDER AGE(I) DARJEELING
2023_MES_607301_1
CWE/136-WE/21 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E, Category b(ii)
9 documents required · 9 mandatory
₹500
AGE(I) Darjeeling
₹30,000
Yes
19 Sept 2023
30 Jun 2023
9 Aug 2023
30 Jun 2023
7 Aug 2023
15 Jul 2023
30 Jun 2023 - 8 Jul 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5mtr in depth for foundation. (Laying of under ground cables) in soft/loose soil and getting out all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil all as directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point all as directed.
M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required cover all as directed.
Supply and laying of fly ash bricks of best qualitylaid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection as directed .
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item excavation/taking down) complete all as directed.
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed .
Supply and lay trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm incl taking down complete all, as specified and directed . Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No.08 above but 2 Core 10 Sqmm
M&L for 40mm dia steel tubes (light grade) galvanised with fittings, clamp, nuts bolts etc laid in trenches or fixed to wall/pole/road crossing for protection of underground cable.
M&L for 25mm dia steel tubes (light grade) galvanised with fittings, clamp, nuts bolts etc laid in trenches or fixed to wall/pole/road crossing for protection of underground cable.
M&L for 15mm dia steel tubes (light grade) galvanised with fittings, clamp, nuts bolts etc laid in trenches or fixed to wall/pole/road crossing for protection of underground cable.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) for mounting of security lights including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Red oxide Primer (Externally from Top of Coping) including writing MES Pole No. with Synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
Supply and fix stay assembly using GI stay rod 16 mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1. (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed.
Supply and fixing loop type insulator large size porcelain vitreous of size 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as directed .
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone agrregates as in pedestal of pole/ strut and in copping including necessary form work and finishing exposed faces of concrete even and smooth using extra cement all as directed.
M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundations of poles,filling and mass concrete complete all as specified.
Material and labour for spreading /Loose filling with aggregates of gauge 40-80MM mm size, evenly inSwitch Yard or power house complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of part I including necessary excavation and earth work GI pipe 40mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to HT/LT poles/panel board as indicated including testing complete.
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 200 Amps, 3 pole / 4 Pole, 36 KA,ics=icu=100% 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed.
All as per item No. here in before but of capacity 160 Amps, 4 pole, 16KA, ics=icu=100%
All as per item No. 24 here in before but of capacity 25-100 Amps, 3P, 16 KA,ics=icu=100%
All as per item No.24 here in before but of capacity 125 Amps, 3P, 16 KA,ics=icu=100%
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed .
Supply & fix in Replacement street light fitting LED type 100 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit and necessary mounting arrangements where required etc and taking down old unsv any size/watt of security light all as directed .
Supply & Fix in Replacement LED Flood light 120 Watts fitting ,IP65 protection and including mounting arrangements where required /driver unit etc and taking down old unsv any size/watt of flood light all as directed.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern & etc taking down old unsv cable all as directed.
S & F On Load changover switch (4 pole) 100A
S & F On Load changover switch (4 pole) 63A
S&F Pole box with suitable terminal connector for single/three phase connctions loop in and out 10 to 16 Sqmm 2/4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polysterene/polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, flame retradant glow wire test at min 75°C internally embeded gasket with provision for cable entry through IP 66/67 themoplastic metric size glands and/or grommets enclosure size (155 X 210 X90 LBH), GI clamps made out of GI flat of size 25mm X 3 mm bend to shape incl 01 No MCB 6A and making connections all as directed.
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/3.5/4 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed. Note: ( Earth work, sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item)
Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work, sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevent Item)
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 35 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and directed.
All as per item No 37 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 60-90 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 100/110/120 watts LEDstreet light fittings/ flood light fittings of any make complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
supply & fix in Replacement street light fitting LED type 30Ws with extruded aluminium construction complete all as directed.
supply & fix in Replacement seperator for LT overhead conductor incl all arrengement complete all as specified and directed.
Repair/Maint of APFC Panel of Capacity 75 KVAR to 125KVAR after disconnecting all connections for fault, finding/trouble shooting and carryout necessary repairing works by replacing the defective spare parts, complete all as specified and as directed. Note defective parts will be measured and paid seperately
Supply only 02 KVAR standard duty power capacitor (Extra low loss) suitable for APFC panel, complete all as specified and as directed.
Supply only 05 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed.
Supply only 10 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed.
Supply only 15 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed.
Supply only 20 KVAR capacitor double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed.
S&F in repair capacitor contactors for 20 kVAr capacitor, 415 Volts all as specified and as directed .
S&F in repair capacitor contactors for 10 kVAr capacitor, 415 Volts all as specified and as directed .
S&F in repair capacitor contactors for 5 kVAr capacitor, 415 Volts all as specified and as directed .
S&F in repair control relay (auxiliary contractor), 415 Volts all as specified and as directed .
S&F in repair control relay (auxiliary contractor), 415 Volts all as specified and as directed .
S&F in repair overload relay suitable for contractors, 410 Volts Ac all as specified and directed.
S&F in repairs Indicating lamp Red/Green as per existing complete all as specified and as directed.
S&F in repairs CT coil as per existing complete all as specified and as directed.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected.
GEETA CONSTRUCTION
Darjeeling Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .