| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-Finance | ₹32.4 L | L1 | Accepted-Finance Lowest and reasonable |
| 2 | L2₹36.9 L+₹4.5 L (13.9%)Rejected-Finance | ₹36.9 L+₹4.5 L (13.9%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹38.7 L+₹6.3 L (19.4%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹38.7 L+₹6.3 L (19.4%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹38.8 L+₹6.4 L (19.9%)Rejected-Finance | ₹38.8 L+₹6.4 L (19.9%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹41.8 L+₹9.4 L (28.9%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹41.8 L+₹9.4 L (28.9%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
22 Apr 2025, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180003
PROVN OF CERTAIN E M WORKS AT CERTAIN HANGERS AT AFS UNDER GE AF PATHANKOT
2025_MES_702272_1
CWEAFJ-48/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
All as per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Pathankot
₹79,000
Yes
30 May 2025
25 Mar 2025
24 Apr 2025
25 Mar 2025
22 Apr 2025
8 Apr 2025
Amount
Supply, installing, testing and commissioning outdoor type floor mounted step up/ down transformer, 11KV/433 Volts (at No load) AC 3 Phase 50 Hz, 315 KVA Capacity, core type, double copper wound oil immersed, Oil Natural- Air Natural (ON AN) cooled, with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with Neutral brought out on secondary side (LV Side) and having tapings at 2.5% and ± 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45°C in oil and 55°C in HV/ LV winding when measured by resistance method after continuous full load run on an ambient temp of 40°C. The transformer shall be as per IS 1180 (part-10/2014 EE Level-2 ) standards and shall comprise of the following:-
(a) Three Nos porcelain bushing suitable for 11 KV on HV side, complete with brass rods, nuts and washers.
(b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with brass rods, complete with nut and washers, with cable glands suitable for reception/ taking out of 03 Nos single core 300 Sq mm and one No single core 150 Sqmm, LT 1100 volts grade XLPE insulated and sheathed, heavy duty, armoured cables including joints and jointing materials complete.
(c) Oil conservator with filter type drain valve and oil level guage.
(d) De-hydrating breather with first fill of dehydrating agent (Silica Gel)
(e) Exposive vent, Thermometer pocket on tank cover, Oil level guage, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, Air release valve plug and four Nos. plain solid vast steel detachable rollers
(f) One No 100 mm dia, dial type thermometer, vapour pressure release type having range 0-200º C with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 50X6 mm galvanised iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral.
(k) First filling of new and unused transformer oil, IS-335 marked (Make: Savita/ Power Link) filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all specified and directed by Eng-in-charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 240 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc, complete all as specified and as directed by Engr-in-Charge.
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road / path /drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 185 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 120 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 50 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 35 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply, laying, jointing and testing fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 25 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with act and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, all as directed by Engineer-in-Charge.
S&F Sheet Moulding Compound (SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/ Siemens/L&T equivalent product code No. GSJB-2817 of size 280mm X170mm X130mm, complete, all as directed by Engineer-in-Charge.
S&F Saucer Nextgen Highbay, energy saving ,robust highbay LED 120 watt with PDC housing suitable for ceiling/ suspended mounting with system efficiency upto 150 im/w complete all as specified and directed by Engineer-in-Charge..
S&F LED flood light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with act and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge..
Taking down old and u/s MCCB DBs / MCB DB / Main Switches including MCBs/MCCBs/ Isolaters, from wall surfaces all as specified and directed. Note : Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP & N 4 ways vertical type MCCB DB, with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management complete all as specified and directed by Engineer-in-Charge..
S&F factory made epoxy powder coated distribution board double door VTPN 8 ways vertical type MCB DB, with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management complete all as specified & directed.
S&F factory made epoxy powder coated distribution board double door TPN 4 ways vertical type MCB DB, with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management complete all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs, complete all as specified & directed.
All as per item No. 18 above but DB SPN 8 ways.
All as per item No. 18 above but DB SPN 4 ways.
Supplying & fixing in replacement MCCB, 4 pole, 63 Amps , 16 KA current rating conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified & directed.
Supplying & fixing in replacement MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed.
Supplying & fixing in replacement MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified & directed.
Supply and fixing in repair MCB single pole 240 volt C curve 10 KA 5 to 32 Amps capacity, complete all as specified & directed.
Supply and fixing in repair MCB single pole & neutral 240 volt 'C' curve 10 KA 40 Amps complete all as specified and directed.
Supply and fixing in repair MCB TP 415 Volt C curve 10 KA 25 to 63 Amps capacity complete all as specified and directed.
Supply and fixing in repair MCB TPN 415 Volt C curve 10 KA 40 to 100 Amps capacity complete all as specified and directed.
S&F 63 Amps MCCB bus bar chambers factory febricated suitable for 3 Phase & neutral iron clad with 4 Nos 100 amp rated aluminium strips including 01 No incomer of MCCB rating 63Amp 4 Pole, with two Nos Earthing connection bolt with locking arrangement front door operated complete fixed flush in wall and making good the disturbed wall surfaces complete all as required at site or directed by Engineer-in-Charge.
Taking down old and u/s aluminium conductor sub main wiring of 2/3 runs or main-wiring or twin core flat cable of any sizes from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc all as directed and making good disturbed surface of wall ceiling etc, complete all as specified and directed.
M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including PVC conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor complete all as specified and directed.. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
All as per Item No.30 above but sub main wiring using two single core PVC insulated, concealed conduit suitable size ,unsheathed FRLS multi stranded copper conductor cable of size 4.0 Sqmm with one run of PVC (green colour) insulated, unsheathed, FRLS multi stranded copper conductor of size 4 Sqmm as earth continuity conductor, complete all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
M&L for Sub main wiring complete with 4 runs of 10 Sqmm single core PVC insulated unsheathed cable 1100V, FR grade with multistranded copper conductor ISI marked drawn through PVC rigid conduit and accessories fixed on surface/wall celing etc including provision of 2 run of 10 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity, complete all as specified and directed. Note : Two runs of copper conducter and one runs of earth copper conducter shall be measured as one length.
All as per above Srl Item 32 above but sub main wiring using two single core PVC insulated,conduit suitable size, unsheathed FRLS multi stranded copper conductor cable of size 2.5 Sqmm with one run of PVC (green colour) insulated, unsheathed, FRLS multi stranded copper conductor of size 1.5 Sqmm as earth continuity conductor, complete all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
S&F PVC conduit of size 25 mm dia in wall / surface for existing telephone cable / Lane cable all as directed and specified by Enge in charge.
S&F Industrial plug (PP06P) 125 Amps,415 volt,three phase,5 pin metal enclosure and socket all as specified and directed.
S&F stainless steel pre Galvinized 50x50 mm perforated cable tray ,chanel type on ceiling in bldg ,proper hanging ,nut bolt PVC conduit of size 25 mm dia in wall / surface for existing telephone cable / Lane cable, complete all as directed and specified by Enge in charge.
M&L for earthing complete with copper earth plate elect rode 600x600x3mm thick buried directly in ground to a depth not less than 3 mtr deep below normal ground level with top edge of the earth plate not less than 2.25 mtr deep below normal ground level connected to copper strip 20x3mm size as earthing lead by means of soldering/brazing and bolts, nuts, check nuts and washers of brass, GI protection pipe light grade 40mm bore up to test point 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:2:4 type B-1, RCC cover with suitable handle, earth pit filled with ground enhancing material i.e. mixture of copper sulphate, magnesia sulphate, graphite power etc mixed in equal quantity all around earth plate up to 150 cm and filled with vegetable soil above GEM up to ground level earth work in any type of soil all as required and directed including testing on completion.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanisediron strip 32x6mm size by means of welding,bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1 , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 2009 Part-I, complete , all as specified and directed .
M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with 6mm dia M.S. round bar placed 75mm c/c and handle of 10mm dia, MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 meter long placed on top edge of earth plate, common salt & charcoal filling, funnel, wire mesh and earth work not exceeding 50 meters all as per electrical plate No 5 of SSR Part I (2009) and connected to earth test points all as specified and directed including testing on completion.
Supply,installation, testing & commisioning LT Panel board, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, outer body made out of 3.15mm thick & inner shell made out 2.00mm thick CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated and conforming to IEC-61439 part I & II, The cubical shall have frame work, bottom & 45CM long four legs of size 50 X50 X 6 mm Angle iron, Aluminum main busbar of incomer switch gear duly sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and control wiring with multistranded PVC insulated copper wire size not less then 1.5 Sqmm, complete comprising with following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder piller box shall be mounted on PCC 1:2:4 type B-1(with 20mm grade crushed stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item., complete , all as specified and directed .: At Site Sub Station No-3 Note :- Panel should be TTA in accordance with IEC-61439 part I & II
(b) Outgoing MCCB FP LT 415 volt 50 Hz, AC 160 Amps 36 KA with adjustable thermal setting With Extended Rotary Handle, Spreaders, Phase Barrier.- 08 Nos (i) On/ off/ trip indicator 08 Sets (ii) Auxiliary 1 C/O + TAC 1 C/O 08 Nos (iii) Control MCB 2A SP 10KA- 08 Nos (iv) Automatic changeover 250A FP - 01 No
(c) Outgoing MCCB FP LT 415 volt 50 Hz, AC 100 Amps 16 KA with adjustable thermal setting With Extended Rotary Handle, Spreaders, Phase Barrier.- 03 Nos (i) On/off/trip indicator 03 SETs (ii) Auxiliary 1 C/O + TAC 1 C/O 03 Nos (iii) Control MCB 2A SP 10KA 03 Nos
Supply and fixing LT panel board outdoor type fabricated out of 3.15 mm thick MS sheet, back door detachable type mounted on 45 cm high base frame made out of angle iron 40x40x6 mm duly painted and fitted on PCC base of 1:3:6, 20 mm graded stone aggregate with nuts, bolts and washers and front doors fixed with hinges and knobs, painted on all the surfaces with two coats of synthetic enamelled paint over a coat of red oxide primer complete suitable for 415V, 50Hz, 3 phase, 4 wire with and incl the following:-( Near bldg LT Panel)
[a] MCCB 315 Amps 36 KA Four pole 415 volts with adjustable thermal and magnetic setting - 01 No (incomer) [b] MCCB 160 Amps 36 KA Four pole 415 volts with fixed thermal and magnetic setting - 02 Nos (O/G) incl Spare - 01 No. [c] MCCB 125 Amps 16 KA Four pole 415 volts with fixed thermal and magnetic setting - 01 No (O/G) [d] MCCB 63 Amps 16 KA Four pole 415 volts with fixed thermal and magnetic setting - 01 No (O/G) (e) Time switches luxo switch/ light senstive switch with Lux sensor- output 16A, 250V [f] Copper busbars sleeve insulated 160 Amps capacity TPN mounted on epoxy insulators - 01 Set [g] Digital panel meter for Ampere, volt, KWH, power factor and other parameters flush mounting of 96x96 mm. [h] Indicators RYB - 01 Set [j] Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses. [k] Cable entry glands and two Nos. earthing terminals Note :- Panel should be TTA in accordance with IEC-61439 part I & II
M&L in replacement for maint free chemical earthing pit for Electric Equipement/lightening protection comprising of 3 Nos copper earthing Electrode Compound filled Model 80 MTPBC, Length 3000mm internal strip size 32X6 Copper electrode diameter 80 mm . Fixed in Three different earth pit of size 3.3 mtr deep placed in a triangular position at a distance 3 mtr each, earth pit filled with earth gel with hardener Soil Resistivity improvement Powder Compound make of compound True (hygroscopic in nature) earth electrodes inter connected using copper strip of size 25 mm x3 mm and one test point made of copper plate of size 75x75x3mm thick connecting to all three earth pits using copper strip of size 25x3 mm with soldering or brazing all as required including boring hole for earth pits and removal of surplus soil , refilling of vegetation soil and earth pits FRP Earthing chamber cover earthing pit .Earthing Chamber FRP 420mm (Top),340mm (Base),210mm Height for test points and FRP Based Earthing Display Board with support stand , FRP coated width 254mm,Length-380mm, Height 610mm., complete all as required and directed.
S&F in replacement for single pointed air termination aluminium rod 12mm dia 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as mass concrete for foundation , complete all as specified and directed by Engr-in-Charge.
M&L for test point terminal block made of steel plate of size 75x75x6 mm drilled and screwed including 3 Nos 8mm dia 25 mm long hex. head screw complete all as specified and directed by Engr-in-Charge.
S&F in replacement for aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fibere and fixing screws all as required at site or directed by Engr-in-Charge. Note :- Insulators should be approved quality & backlite fixing tightly so that it does not fall of during winds / rains.
S&F in replacement for copper strip 20x3.15 mm complete with saddles/ insulators made out of porcelain or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by Engineer-in-Charge..
Dismantling existing transformer of 100 KVA capacity by dismantling all the electrical connnection, transporting it to MES store yard and depositing it with MES.
S&F cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation, complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer -in-charge.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.
Sand cushioning to under ground cable, provided with 8 cm thick layer before laying the cable and 15 cm thick layer after laying and stretching the cable complete all as specified and directed. Note :- Sand cushioning to be punned as per SSR Part-I and punned thickness only to be measured and paid.
M&L for Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation of poles / stays etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping including necessary form work finishing the cement concrete surfaces even & smooth using extra cement complete all as specified and directed.
M&L for Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
M&L for Steel pipe galvanised light grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
M&L for Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
dadwal engineers (BID ID -3286089)
Vijay Kumar Contractor and Engineers (BID ID -3285967)
Auto India (BID ID -3282252)
JCC ENGINEERS PRIVATE LIMITED (BID ID -3281679)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .