| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LQualified | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹20.9 L+₹1.5 L (7.80%)Qualified 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹21.0 L+₹1.6 L (8.34%)Qualified NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L3 | Qualified MSE, MII, Category: General | |
| 4 | L4₹22.1 L+₹2.7 L (14.1%)Qualified 01 VILLAGE BABOORI BARARI MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L4 | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Nov 2023, 9:00 pmClosed
and removing the sludge and silt
All as per item No. 13 but Raw sewage water tank of size 2.6m x 2.4m x1.4m deep at STP 0.250 MLD and removing the sludge and silt
S and F in replacement filter media for sludge drying bed Sand 2.5mm to 4.75mm including taking out existing filter media
S and F in replacement filter media gravel of size 6.5mm to 15mm for sludge drying bed coarse type including taking out existing filter
Taking out filter media carefully from Daul media filter activated carbon filter and depositing at a distance not less 50 mtr where directed
Re use of gravels of size 40 to 6mm obtained from item above after screening and segregation size wise and washing cleaning with using suitable non toxic chemical acid
Supply and lay MNO2 compound duly treated in activated carbon filter of size 2200mm dia x 1800mm height at 1250 KLD STP
Supply and lay in layers activated carbon compound duly treated in activated carbon filter of size 2200mm dia x 1800mm height at 1250 KLD STP
Supply and laying in layers pea gravels duly cleaned and washed of following grades complete all as specified and directed A. 40mm to 30mm grade
B. 30mm to 20mm grade
C. 20mm to 10mm grade
D. 6mm to 10mm grade
Supply and laying in layers filter sand of uniform grading of 16 or 32 mess size dry and cleaning properly complete all as specified and directed.
Supply and lay MBBR media duly treated in MBBR I and II at 250 KLD and 1250 KLD STP complete all as specified and directed.
Cast iron pipe with flanged ends including nuts bolts washer and neoprene rubber gasket jointcentrifugally cast class A in any length for replacement A. 80mm bore.
B. 100mm bore
MS ERW pipe fixing with header non return valves sluice valves etc. laid on pillars as per existing including taking down old unserviceable pipe size in replacement A. 65mm bore.
B. 80mm bore.
C. 100mm bore
D. 150mm bore.
M and L for Cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending etc
Butterfly valve of cast iron body as per IS 13095 ISI marked heavy duty including nuts bolts washer and neoprene rubber gasket joint size in replacement A. 65mm bore.
C. 100mm bore.
Cast iron body sluice valve heavy duty class PN 1.6 of 150 mm bore ISI marked with IS 14846 both flanged ends and drilled with forged brass spindle A.100mm bore.
B. 150mm bore.
Cast iron body NRV ISI marked with IS 14846 both flanged ends and drilled with forged brass spindle CI gate with brass ring non rising type A. 100mm bore.
B.. 150mm bore.
Supply and fixing in replacement of cast iron foot valve ISI marked with gun metal flapper and high quality pressure stop gasket nuts bolts and washers etc A. 65 or 80mm bore
B. 100mm bore.
C. 150mm bore.
M and L for carrying out maintenance repairs by removal and dismantling air blower throughly cleaning correct setting timing of impellers
All as per item No 47 above but Cap 185 Cum hr type UGRK 140SS complete all as specified and directed.
S and F in replacement of following parts for making the air blower make Uhsa Air Compressor
Air filter of Usha air blowers cap 185 Cum hr as per existing complete all as specified and directed.
Supply and filling of oil grade castrol Hypo B 90 servo gear super 90 HP gear oil X P90 for replacement top up
Air blower Belt size as per existing size STP .25MLD complete all as specified and directed.
Air blower belt as per existing size stp 1.25mdl
Blower Bearing as per existing
size STP 0.25MLD complete all as specified and directed.
size STP 1.25MLD complete all as specified and directed.
Sodium
5525484
GEM/2023/B/4144336
Two Packet Bid
Under ground sewage sump well of size internal dia 4.0m and depth 9.0m complete all as specified an
150 days
Punjab; Jalandhar
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
40%
Exempted
10 Nov 2023
28 Oct 2023
7 Nov 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Under ground sewage sump well of size internal dia 4.0m and depth 9.0m complete all as specified and directed. | Under ground sewage sump well of size internal dia 4.0m and depth 9.0m complete all as specified and directed. | 4 | each job | anil11 | 150 |
| 2 | Under ground sewage sump well of size internal dia 6.0m and depth 9.0m complete all as specified and directed. | Under ground sewage sump well of size internal dia 6.0m and depth 9.0m complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 3 | Under ground sewage sump well of size internal dia 5.20m and depth 4.5m complete all as specified and directed. | Under ground sewage sump well of size internal dia 5.20m and depth 4.5m complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 4 | Under ground raw sewage water sump of size 10.0m dia and 2.5 deep at STP 1.2 MLD complete all as specified and directed. | Under ground raw sewage water sump of size 10.0m dia and 2.5 deep at STP 1.2 MLD complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 5 | Under ground sewage sump of size 4.6m x 4.6m x4.6m deep.at STP 0.25 MLD complete all as specified and directed. | Under ground sewage sump of size 4.6m x 4.6m x4.6m deep.at STP 0.25 MLD complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 6 | Raw sewage water tank of size 8.3m x 2.5m x2.5m deep at STP 2.0 MLD complete all as specified and directed. | Raw sewage water tank of size 8.3m x 2.5m x2.5m deep at STP 2.0 MLD complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 7 | Raw sewage water tank of size 2.6mx2.4mx1.4m JCO ORs MAP Qtrs complete all as specified and directed. | Raw sewage water tank of size 2.6mx2.4mx1.4m (JCO ORs MAP Qtrs) complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 8 | Chlorine contact tank of size 8.3mx2.5mx2.5 STP 1.2MLD complete all as specified and directed. | Chlorine contact tank of size 8.3mx2.5mx2.5 (STP 1.2MLD) complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 9 | Chlorine contact tank of size 2.5mm and 2.50mx1.4m STP 0.25MLD complete all as specified and directed. | Chlorine contact tank of size 2.5mm and 2.50mx1.4m (STP 0.25MLD) complete all as specified and directed. | 1 | each job | anil11 | 150 |
| 10 | Cleaning and desludging of sewage sump well of size internal dia 4.00m and9.00m deep from ground level by removing sludge and slit completely | Cleaning and desludging of sewage sump well of size internal dia 4.00m and9.00m deep from ground level by removing sludge and slit completely with suitable means(mechanical and/or manual) from the bottom of sewage sump by scrapping out deposit, sludge etc including the side walls of sewage sump well with the help of scraper, wire brush etc cleaning with clear water using pressure water jet. removing the sludge and silt and depositing where directed to a distance not exceeding 08 Kms from the sewage well by covered motor van/ tractor trolley ensuring that sludge does not spoil the roads. cleaning the area around the sewage sump not exceeding 2m on either side including cutting of bushes etc and cleaning the site complete (approx deposit of sludge/silt 0.95 mtr height). | 4 | each job | anil11 | 150 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_5525484.pdf
GEM_BID
sewage_2023-10-28-20-18-37_4fe2c38d9c37db1b933cff25f04c06cb.pdf
BOQ
sewage_2023-10-28-20-18-37_5c966f48e5d25000341c699fcbdf0258.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .