| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.7 LAccepted-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹57.7 L | L1 | Accepted-Finance Qualified as Rank L1 |
| 2 | L2₹67.8 L+₹10.2 L (17.6%)Rejected-Finance 32A GROUND FLOOR ANSAL CLASSIQUE TOWER RAJOURI GARDEN NEW DELHI 110027 | WEST | DELHI | 110027 | ₹67.8 L+₹10.2 L (17.6%) | L2 | Rejected-Finance Rank L2 |
| 3 | L3₹74.7 L+₹17.0 L (29.4%)Rejected-Finance 17 JASDEEP OMPLEX 17 JASDEEP OMPLEX RK ROAD RK ROAD LUDHIANA PUNJAB 141003 | LUDHIANA | PUNJAB | 141003 | ₹74.7 L+₹17.0 L (29.4%) | L3 | Rejected-Finance Rank L3 |
| 4 | L4₹74.9 L+₹17.2 L (29.8%)Rejected-Finance | ₹74.9 L+₹17.2 L (29.8%) | L4 | Rejected-Finance Rank L4 |
| 5 | L5₹75.3 L+₹17.6 L (30.5%)Rejected-Finance | ₹75.3 L+₹17.6 L (30.5%) | L5 | Rejected-Finance Rank L5 |
Tender Value
₹64.9 L
EMD Value
₹1.3 L
Closing Date
6 May 2026, 3:00 pmClosed
Executive Engineer(E)
Executive Engineer (E), PWD HMED SW (NCTD), Ist floor, Samaj Sadan, DAP Lines, Vikas Puri, New Delhi
SITC of Air Cooled Cassette Type Air Conditioner System in B-block at Guru Gobind Singh Govt. Hospital, Raghubir Nagar, New Delhi
2026_PWD_290474_1
14/EE(E)/PWD HMED SW/2026-27
Open Tender
Electrical Works
Works
60 days
Guru Gobind Singh Govt. Hospital
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.3 L
21 May 2026
28 Apr 2026
6 May 2026
28 Apr 2026
6 May 2026
28 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. Inverter Type- Cooling only | |||||
| 1.01 | 1.5 TR with 5 Star BEE Rating | 4 | Each | 77,417 | ₹3,09,668 |
| 1.02 | 2.0 TR with 5 Star BEE Rating | 24 | Each | 85,731 | ₹20,57,544 |
| 1.03 | 3.0 TR with 5 Star BEE Rating | 10 | Each | 1,23,684 | ₹12,36,840 |
| 1.04 | 4.0 TR with 5 Star BEE Rating | 10 | Each | 1,42,201 | ₹14,22,010 |
| 2 | SITC of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 1.5 TR / 2 TR/ 3 TR/ 4 TR STAC duly insulated by nitrile rubber along with 3 core x 2.5 Sq.mm. copper cable & than inserted in the PVC flexible pipe with necessary support as required as per site requirement., testing i/c less credit of old dismantle material complete etc as reqd. | 500 | Meter | 1,268 | ₹6,34,000 |
| 3Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 3.01 | 3 x 4 sq. mm | 700 | Meter | 222 | ₹1,55,400 |
| 4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||||
| 4.01 | 25 mm | 600 | Meter | 168 | ₹1,00,800 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_385520.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .