Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹7.5 L+₹32,571.59 (4.55%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹7.8 L+₹60,578.09 (8.46%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹7.9 L+₹74,578.09 (10.4%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹8.2 L+₹1.0 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 Oct 2020, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
OUTSOURCING FOR MANNING OPERATION AND REPAIR MAINT SERVICING OF SEWAGE DISPOSAL MOTORS IN DOMESTIC AND TECH AREA AT AF STATION BARNALA UNDER GE AF HALWARA
2020_MES_379686_1
GE/HAL-39/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Halwara
MES ENLIESTED CONTRACTORS CLASS E CATEGORY d v
11 documents required · 11 mandatory
₹500
Yes
GE (AF) Halwara
₹20,000
Yes
24 Nov 2020
22 Sept 2020
28 Oct 2020
22 Sept 2020
26 Oct 2020
5 Oct 2020
Amount
BOQ (Part-I, OUTSOURCING SERVICES AGAINST SL ITEM NO 1 TO 3 ONLY)) Manning & operaion of sewage installation in one shift from 0900 hrs to 1700 hrs (Each shift of 08 hrs) to be operated by one operator per shift in domestic area at sewage pump house No -02 (Cdr Chowk) comprising of the machine/equipment including all minor repair and smooth functioning of pump sets
Manning & operaion of sewage installation in one shift from 0900 hrs to 1700 hrs (Each shift of 08 hrs) to be operated by one operator per shift in domestic area at sewage pump house No -01 (Dhobi Ghat) comprising of the machine/equipment including all minor repair and smooth functioning of pump sets.
Manning & operaion of sewage installation in one shift from 0900 hrs to 17oo hrs (Each shift of 08 hrs) to be operated by one operator per shift in domestic area at sweage pump House No 03 (Main Guard Room)_ comprising of the machine/equipment including all minor repair and smooth functioning of pump sets. Note for item No 1 to 3 - Major part of pump sets for repair if required shall be measuread and paid seperately) (a) Dusting and cleaning of of LT panel and starter inside and outside of the sewage permises is the full responsibility of contractor. (b) Cleaning of surrounding area is the full responsibility of the contractor and any negligency occured in cleaning by weekly inspection by the undersigned a fine of Rs 1000 (one thousand ) will be deducted from the bill. ( c) Rectification of minor electrical faults in panel and starter replacement of burnt copper /AL wire upto 30 CM with lugs is the responsiblity of the contractor. (d) Emergency electrical fault occured in the entire system will be rectified by contractor. (e) The following equipment intalled in installation shall be the reponsibility of contractor to maintain and he will also be responsible for any damage of property. (i) Non clog centrifugal sewage pumping set driven by three phase electric driven motor 12.5 HP (02 Nos ) , 440 Volts, 1440 RPM complete with panel. (ii) Sluice valve & reflex valve complete with suction and delivery pipe. (iii) Internal electrification as per inventory
NOTES for item No 1 to 3 (Contd...) (g) No payment to Conactor shall be made unless proof of online payment of wages to the workers/labour Aadhar linked bank account is submitted by the contractor. proof of slatutory deduction in favour of workers/labour shall also be submitted by the contractor. (h) The amount for contribution toward EPF, ESIC'and bouns shall also be payble after submission of vaild and authetic document as proof of payment. (j) The rates quoted for items of outsourcing shall not be less than minimum wages as notified by goverment of India/concemed state goverment/local body whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective headings/sub-items in case the rates quoted are less than the prevailing rates/instructions under any heading(s) the bid will be treated as non-bonafide/invaild, shall be disqualified and such bids will not be considered for acceptance. In such case the lowest bider shall be detemined from amongst the vaild/bonafide bids only. (k) Quotations with Nil or Zero consideration (overhead and profit) shall be considered non bonifide. (l) GST shall deemed to be included in the rates quoted against items of outsourching Any variation in tax(including variation in GST rate) shall be adjusted and reimbursed to/recovered from the contractor. (m) Any varition in minimum wage, liablity of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Varition in minimum wage including other related statutory provision shall be adjusted in items of condition 63 of GCC (IAFW-2249) (ii) Varition in percentage/rate of GST and LWC shall be adjusted as specified.
NOTES for item No 1 to 3 (Contd....) (n) Rates shall be quoted only upto two digits after decimal if any rates quoted/derived by the contractor works out to more than two digits after decimel then the same shall be rounded off upto two digits after decimal. The rounding off shall be done in accordance with rules rounding off of Numercial values in accordance with IS-02 of 1960 (Revised 2016) of BIS. (o) The contractor will be required to submit copy of valid licence from the labour commissioner within 15 days of commencement of the work, if the contractor fails to submit the same within this stipulated period, the contract shall be lible to be cancelled and the performance security of the firm shall be forfeited accordingly. (p) The contractor will provide suitable reliver (Trademen) during weekly rest of employed workers without any extra cost to department). (q) The contractor or his represetative (supervisor) would maintain the daily complaint register/complaint slip/log book/duty roster and required douments and putup all the documents once in a week to JE concerned/Engr-in-charge. (r) Trademan should inform to JE concerned about any major breakdown. (s) The contractor will provide full dress to the staff employed by him and no duty will be perform without proper dress.
BOQ (PART-II) REPAIR/MAINT SERVICES FOR SL ITEM NO 6 TO 22) M&L for cutting and removing the existing rusted flange of coloumn pipe and refix new flange including cutting of coloumn pipes threading and welded with 2 Nos heavy duty flange not less than 12mm thick duly drilled with cable slot all as directed.
M & L for flat iron clamp 75 cm long of size 100mm x 6mm thick made out of MS suitable for 100mm bore GI pipe with complete nuts, bolts and washer etc.
S&F in replacement MCCB 415V AC, 4 pole current rating 125 Amp with breaking capacity 16 KA with fixed magnetic and thermal settings complete all as directed.
S&F in replacement MCCB 415V AC, 4 pole current rating 100Amp with breaking capacity 16 KA with fixed magnetic and thermal settings complete all as directed .
Dismantling and taking out non-clog sewage pump set suitable using for motor 12.5HP, 3 phase capacity form foundation disconnecting all connections and transpoting to work shop for pump repairing purpose and taking out the worn out pump parts , overhauling including shaft metaling, welding and grinding the shaft and replacing of all worn out/defective parts of pumps and making it in properly serviceable condition and re-assembling at site including refixing in same position after repair work and connecting the electic supply testing complete all as specified and as directed Note : All repair to Centrifugal pump incl mechanical work & replacement of spare if any will be measured and paid seperately under relevant item.
Supply & fixing mild steel coupling with rubber bush as per existing sample with nuts and bolts suitable for 12.5 HP non clog pump set, complete all as specified and directed.
Supply & fixing ball bearing as per existing sample suitable for 12.5HP non - clog pumping set complete all as specified and directed.
S & F in repairs impellers for centrifugal,monoblock, sewage pump,12.5 HP capacity supplied by the original manufacturer after taking out old unserviceable impeller complete all as specified and directed.
S & F gland box iron for 12.5HP non clog pumping set complete all as per specified and directed.
S&F Rubber coupling for suitable size of 12.5 HP non clog pump set as per sample.
M&L for removing rewinding and refixing of induction motors 12.5 HP for sewage centrifugal pump set, opening of motor,cutting removing old burnt winding coils ,cleaning filling the starter slots necessary mechanical works for shaft/bearing housing , rewinding with suitable gauge of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearings, two coats of synthetic enamel spray painting, suitable main connections from coil to tterminal box,preparing and inserting coil running/starting winding interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and fro transportation, testing at site and satisfactorily running all as specified and directed .
M & L for suction pipe line 100mm bore GI heavy grade with flange, 4 hole for sewage pump complete with nut bolt and gasket as specified and directed.
M & L for suction pipe line 80mm bore GI heavy grade with flange, 4 hole for sewage pump complete with nut bolt and gasket as specified and directed.
Supply only LT tape high adhesive 30 mtr lengh 25 mm width all as specified and as directed
Supply and fixing of mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,dia meter of neck in 11 to 15 mm , each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long all as specified and as directed.
Taking out old burnt gland from pump and replacement of new gland packing, cleaning and greasing complete & testing all as directed by the Engineer-in-Charge.
M&L for PVC pipe 100mm dia, heavy duty nylon/PVC braided with connected to suction side of pump line with suitable clamps complete all as specified and directed.
Repair to the foundation of centrifugal motor of different capacity with cement motor and aggregate of ratio 1:2:4 & replacement of foundation bolts & nuts complete all as specified and directed.
S&F ML 2, FASD starter with relay range 12 to 21 Amp, 3 phase 415 volt complete all as specified & directed
CHOUDHARY ENTERPRISES
M/S SANGA SINGH AND CO
NARINDER KUMAR SONS
IK ONKAR ENGINEER AND CONTRACTOR
JASSI TRADERS
M/S J N TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .