MU BLOCK PITAMPURA DELHI 110034
Renovation / Strengthening / Servicing of ALSTOM make transformer HT panel, VCB at Sec 23 BPS
2020_DJB_196146_14
e NIT No 14 EnM NW 2020 21
Open Tender
Miscellaneous Works
Item Rate
60 days
MU BLOCK PITAMPURA DELHI 34
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
A/C NO. 50448339804
₹17,900
11 Dec 2020
29 Oct 2020
4 Nov 2020
29 Oct 2020
4 Nov 2020
29 Oct 2020
Dismantling of HT Panel VCB including bushing, moving contact and operating mechanism etc as required,
Servicing of VCB, cleaning of inner male & female contacts with CRC Repairing of Operating mechanism for smooth operation of VCB Assembling of VCB after. Rectification of wiring etc. as required
Servicing of Vacuum contactor , cleaning of vacuum bottle, solonite coils and Auxiliary contacts with CRC Repairing of Operating mechanism for smooth operation of vacuum contactor Rectification of wiring etc. as required
Calibration and testing of 30 V DC relay for tripping system. The job includes Disconnection of relay from the panel and calibration after servicing and testing with Primary injection test. The job includes the replacement of defective wiring as reqd as Site
P/Fixing of indicating lamp unit with holder L&T make
Repairing of P.T. Replacement of HT Fuses –3 Nos. Replacement of auxiliary contacts
P/Fixing of power pack of rating 110 V /30 V DC for providing the supply to the tripping system Make Mahamai
Insulating the bus bar supporting HT insulator with epoxy paint
Wiring of panel for protection relays and metering system
Calibration of HT CT with primary injection set and testing the same as per site requirement
Assembling the complete panel & testing on load for satisfactory performance
100 KVA TransformerDisconnecting of HT supply from main HT panel after proper switching off 11 KV VCB discharging the supply. Complete drain out of transformer oil from transformer to empty oil drum by oil machine, dismantling of conservator tank all protection relays cable end boxes vent pipes and other items as required.
Cleaning of transformer oil tank and removing of sludge settled in the bottom with the help of vacuum pressure cleaning machine thoroughly, cleaning of core and winding of transformer with hot oil and proper safety precaution to prevent the winding damage as required, cutting of old overheated insulation of winding and re-insulation of weak point with the help of HT insulation material and proper taping etc. Heating the HT & LT winding with inductance heating, removing the moisture improvement the IR value of HT & LT Winding
Replacement of top cover gasket vertical vent gasket & missing hardware to stop the oil leakage
Replacement of silica gel.
Insulating the HT leads
Complete assembling of transformer cleaning of complete transformer tightening of all connection of incoming and outgoing side and testing & checking of IR test with megger of winding & cable of both sides with HI pot machine.
Filling of T/oil to up to top up level as required to make power
P/Fixing of winding protection pad
Dehydration & filtration of complete transformer oil and checking the die electric strength up to 50 KV at site as required
Complete cleaning and chemically washing of oily and muddy transformer body and painting of transformer with enamel paint.
TIMEX ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .