Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹23.5 L+₹2.2 L (10.6%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.5 L+₹4.3 L (20.2%)Rejected-Finance NA | NA | NA | 121004 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.6 L+₹5.4 L (25.6%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.2 L+₹13.0 L (61.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
29 Jun 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/REPLACEMENT OF SWITCHGEAR, LOOPING BOX, CHANGEOVER SWITCH AND ALL OTHER CONNECTED MISC ACCESSORIES AT TECH AREA AND VSV AREA AT AF STN UNDER GE (AF) TUGHLAKABAD
2024_MES_652631_1
GE/TKD-15/2024-25
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹500
GE AF Tughlakabad
₹56,000
Yes
9 Nov 2024
31 May 2024
1 Jul 2024
31 May 2024
29 Jun 2024
15 Jun 2024
Amount
S&F in replacement of PVC cable loop box, size not less than 145mm x 145mm x 95mm, out door type, duly fitted to poles with suitable clamp, nuts, bolts & washers including one No of 6 to 32 Amps single pole MCB, porcelain insulated connectors for incoming and outgoing cables complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 160 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 250 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 400 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 630 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 125 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole 63 amps alongwith spreader /link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacemen of ACB 4 Pole, 415 V, 630 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed by Engr-in-charge
S&F in replacemen of ACB 4 Pole, 415 V, 800 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed by Engr-in-charge
S&F in replacemen of ACB 4 Pole, 415 V, 1600 amps commissioning and testing with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps complete all as specified and directed by Engr-in-charge
S&F in replacement of LED highbay light 150 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source, IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge
S&F in replacement of LED highbay light 100 watts surround type suitable for 240 volts , 50 HZs single phase power supply , fabricated with die cast aluminium with high power LEDs as light source ,IP 66 complete with all standered accessories complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement MCCB 4 Pole alongwith spreader/link, 415 V,adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed by Engr-in-charge
S&F in replacement of MCB TPN 4 pole 16 to 32 amp 415 volt, ;C; curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
S&F in replacement of MCB TPN 4 pole 40 to 63 amp 415 volt ;C; Curve 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
S&F in replacement of MCB SPN 4 pole 32 to 63 amps 240 'C' curve volt 10 KA breaking capacity complete all as specified and directed by Engr-in-charge
S&F in replacement of ON-Load changeover switch 320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
S&F in replacement of ON-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
S&F in replacement of ON-Load changeover switch 400 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
S&F in replacement of OFF-Load changeover switch 320 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
S&F in replacement of OFF-Load changeover switch 200 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
S&F in replacement of OFF-Load changeover switch 400 amps ,415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-charge
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement of LED light fitting 2x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge
S&F in replacement of switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engr-in-charge
Supply, Installation, Testing and commissioning in replacement of APFC capacity 150 KVAR panel in replacement cubical consist of 2 mm thick CRCA sheet (Indoor type) APFC relay & power factor meter & making bank connection with suitable size of copper/busbar, CTR, copper busbar & use with angle iron 50x50x6 mm frame (Bottom portion of the panel) grouting by using PCC foundation (1:2:4 type B-1 with 20 mm graded stone aggregate, thimbling & cable entry boxes with cable gland including locking arrangement & painting with two coats of synthetic enamel paint over a coat of red oxide primer, the APFC panel shall be fully type tested at an independent laboratory & shall comply with IEC 61439-1&2 & IEC 61921, IS-16636 (2017), the degree of protection of enclosure system of APFC panel shall be min IP 41 in accordance with IEC 60529, the APFC shall be indoor type conforming to IS 13341:1992 & 13440:1993 floor mounted design complete all as specified and directed by Engr-in-charge comprising the following:-
S&F in replacement of 3 pole power contactor MNX 325, current rating 600 amp amp 415 volt AC coil voltage 110/220/415 volt AC 50 HZ complete all as specified and directed by Engr-in-charge
Supply, Installation, Testing and commissioning in replacement of APFC capacity 100 KVAR panel in replacement cubical consist of sheet metal steel enclosure of 2 mm thick APFC relay & power factor meter & making bank connection with suitable size of copper/busbar, CTR, copper busbar & use with angle iron 50x50x6 mm frame (Bottom portion of the panel) grouting by using PCC foundation (1:2:4 type B-1 with 20 mm graded stone aggregate, thimbling & cable entry boxes with cable gland including locking arrangement & painting with two coats of synthetic enamel paint over a coat of red oxide primer, the APFC panel shall be fully type tested at an independent laboratory & shall comply with IEC 61439-1&2 & IEC 61921, IS-16636 (2017), the degree of protection of enclosure system of APFC panel shall be min IP 41 in accordance with IEC 60529, the APFC shall be indoor type conforming to IS 13341:1992 & 13440:1993 floor mounted design complete all as specified and directed by Engr-in-charge comprising the following:-
S&F in replacement of A one 4 Kg ABC powder type fire Exitinguisher with wall mounted complete all as specified and directed by Engr-in-charge
Supply and fixing inreplacement of digital Voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of digital Amp meter of range 0-300 Amps alongwith suitable ratio of CTs, single phase, class 01 of size 96 X 96mm suitable for existing LT panel complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement of flame proof exhaust fan & 300mm sweep, 230V, 1440 rpm, CMRI certified recommended recommended for gas/vapor group of Iia & IIIB, Zone 1 & 2 and IP 65 protection with flame & heat resistant body material complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size incl cutting of holes, complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement of Automatic transfer switch of capacity 400 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of Automatic transfer switch of capacity 200 Amp 4 pole,AC-31 A,50 HZ,415 V automatic/ manual with inbuilt time delay complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 4 Pole 1000 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
S&F in replacement of MCCB 4 Pole 800 amps alongwith spreader/link, 415 V,with Microprocessor release with breaking capacity 36 KA complete all as specified and directed by Engr-in-charge
Neeraj Enterprises
M/s Sagar Construction Company
Deepak Electricals
Surjit and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .