Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.8 Cr+₹1.7 L (0.30%)Rejected-Finance | ₹5.8 Cr+₹1.7 L (0.30%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹5.9 Cr+₹10.0 L (1.72%)Rejected-Finance | ₹5.9 Cr+₹10.0 L (1.72%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹13.1 Cr+₹7.3 Cr (126.3%)Rejected-Finance | ₹13.1 Cr+₹7.3 Cr (126.3%) | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹6.0 L
Closing Date
9 Nov 2020, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC PALAM, DELHI CANTT-10
PROVISION OF MARRIED ACCOMODATION FOR DSC AT NTS GURGAON
2019_MES_265112_4
CEWAC/GUR/T-37/2019-20
Open Tender
Civil Works
Lump-sum
455 days
GURGAON
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) GURGAON
₹6.0 L
Yes
8 Jan 2021
14 Oct 2020
11 Nov 2020
14 Oct 2020
9 Nov 2020
27 Oct 2020
14 Oct 2020 - 20 Oct 2020
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of Md accomodation building for one JCO including scooter garage with permanent specifications complete all as specefied as shown on drawings.
Construction of Md accomodation building for one 28 Ors (DSC) (G+7 storey) with permanent specifications complete all as specefied as shown on drawings.
NOTE: Schedule ‘A’ Part II to XI under are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING " as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “FIRE FIGHTING " as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “LIGHTING PROTECTION" as listed in Schedule ‘A’ Part XI
SCHEDULE `A' PART - XII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
S&F LED bulb 09 watt complete all as specified and directed by Engineer-in-Charge. Make:Bajab/philips/Havells.
Supply and fixing ceiling fan 1200mm sweep complete including modular type fan regulator 230 volts (single phase) and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge.Make for Fan : Crompton/Bajaj/ Havells.
Supply and fixing fiber body exhaust fan of size 300 mm sweep, 900 RPM 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed. Make for Exh fan: Crompton/Bajaj/ Havells.
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 90 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.Make:- Crompton Greaves Cat Part No. DMLN1LT8-16 & LTT8-20 or equivalent in Philips/Bajaj/Havells.
S&F LED bulkhead luminaire 10 watt, wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable PVC sheathed complete all as specified and directed by Engineer-in-Charge.Cat No- HLBH-02-10-CW(HALONIX) or equivalant in Phillips/Havells/Osram
S&F LED sleek mirror light fitting 10 watt provided with high output diffuser 2 ft long, 230 Volts complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in-Charge. Cat No- HLB-03-10-CW-AL(HALONIX) or its equivalent in Bajab/philips/Havells. or equivalant in Phillips/Havells/Osram.
Supply & Fixing LED security Flood light fitting 50 watt, having uniformaty ratio 0.25, high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection comlete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed. Cat No- HLFLD-ML17-50-CWL(HALONIX) or its equivalent in Bajab/philips/Havells. or equivalant in Phillips/Havells/Osram.
NOTE FOR ITEM N 3.02 TO 3.08 :- (i) For all types of LED fittings and luminaire should be same manufacturer. (ii) LM -79 cretificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material.(iii) System efficacy should be more than 100 lummens / watt (d) CRI should be 80 (v) THD should be less than 20% (vi) PF should be more than 0.95
S&F sheet metal enclosures Vertical type doubledoor (VTPN) MCCB incomer, with Acrilic Door , cement spill protector For MCCB Triple pole and neutral, 4 ways, IP-43 protection, with 100 Amps rated bus bar breaking capacity 25KA , 415 Volts complete all as specified and directed by Engineer-in-Charge. Make : Indoasian/Legrand/L&T
Supply and fix telephone socket on the phenolic laminated sheet as required.
S&F MCCB 3 pole, 415 Volt, C curve fixed type 100 Amps with breaking capacity 16 KA complete all as specified and directed. Make : Indoasian/Legrand/L&T Cat part No- 830228 of Opti pro INDOASIAN
S&F MCB SP 6 to 16 Amps, C Curve type 10 KA breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811122 TO 811126 of Opti pro INDOASIAN
S&F MCB SP 16 to 32 Amps, C Curve type 10 KA breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811127 TO 811129 of Opti pro INDOASIAN
S&F MCB SPN 32 Amps, C curve type 10 KA Breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811151 of Opti pro INDOASIAN
S/F socket outlet modulor type 6 &16 Amp, 3 & 6 pin combined shuttered type 230volts complete all as specified and directed.
S&F switch modular type 1 way 6 A, one module 230 volts complete all as specified and as directed.
S&F switch modular type 2 way 6 A, one module 230 volts complete all as specified and as directed.
S&F bell push modular type 6 A, one module 230 volts complete all as specified and as directed.
S&F switch modular type 1 way 16 A, one module 230 volts complete all as specified and as directed.
S&F modular metal flush box 2 module complete all as specified and as directed.
S&F modular metal flush box 3 module complete all as specified and as directed.
S&F modular metal flush box 4 module complete all as specified and as directed.
S&F modular metal flush box 6 module complete all as specified and as directed.
S&F modular metal flush box 8 module complete all as specified and as directed.
S&F modular white cover plate with frame 2 module complete all as specified and as directed.
S&F modular white cover plate with frame 3 module complete all as specified and as directed.
S&F modular white cover plate with frame 4 module complete all as specified and as directed.
S&F modular white cover plate with frame 6 module complete all as specified and as directed.
S&F modular white cover plate with frame 8 module complete all as specified and as directed.
ROAD, PATH AND HARDSTANDING
M & L for thermoplastic paint on black top surfaces or existing unpainted surfaces and applied hot mixing plant of heating of thermo plastic materials to a standard temp with gas and laying standard thickness of approximate 2 mm, by using thermo plastic materials @ 6.50 kg/Sqm, and glass beads @ 250 gms/Sqm including cleaning of old surfaces, complete all as specified and directed.
FIRE FIGHTING
Providing supply, erection, commisioning and testing of Gun Metal Air Release Valve 25 mm on wet riser, with shut off Forge Brass ball valve
Providing supply, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 250 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color ( Sample to be approved prior to entire supply) complete all as specified and directed.
Terrace pumps for-440 V, 3 Phase, 50 Hzconfirming to IS- 12469 :1988 With CLCasing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 4A0 volts, 3 phase, 50 Hz 36m head, 900 LPM discharge.
Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system.The panel shouled be suitable for automatic operation for the fire pump as per the specifie parameter. The panel shall be completely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Contineous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable enteries complete all as specified and directed .
Supply and laying of 1mm x 6 core copper wire for electrical pane! complete as required.
Supply.lnstallation, Testing and commissioning of ARM Cortex Microprocessor Based Intelligent Fire Alarm Panel UL listed 9th edition , 40 x 4 Characters LCD display, Maximum 4 number of loop cards with Class A Style 5,6 or 7 / Class B style 4 wiring, 254 devices per loop, Day / Night Mode Facility, USB 2.0 Interface for PC connectivity, RS 485 Communication facility for Network / Repeater, Programmable Auto Silence Facility, Programmable Trouble Reminder Facility, Programmable AC Loss Delay, Programmable Silence Inhibit, Two no's of Programmable Inputs, Loop wise test facility, Battery low visual warning with audible tone, Three Programmable Form C relay for Fire, Fault and supervisory, Two nos. of Supervised Notification Appliance Circuits, Auto dialer /
GSM Module, Ethernet Module, Printer Interface Module, Loop card : 4 Nos. Maximum, Numberof Devices per loop : 254, Loop resistance : 40 (Max.), Loop capacitance : 0.6 pf (Max.), Loop Current: 300mA (Max.), One conventional zone Class B Style B/C operation, Normal Operating Voltage : 14-21 VDC, Alarm Current: 15 - 30mA Short Circuit Current: 45mA Maximum, Loop resistance : 100 Maximum, End-Of-Line Resistor: 4K7, 1/2watt, Standby Current: 7mA (2mA for Detectors) with battrey backup of 30 minutes in alarm condition and 24 hours in Normal Condition Note - The work should execute by the party who is having Manufacturer Authorization support letter.
Supply,installation,Testing and commissioning of Addressable Manual Pull Station, ULJisted 9th Edition,Type A Indoor Use, Resettable by an align key,shall painted by Die casting Housing,shall have a break Glass Rod,Shall have Single gang Mounting,Shall be RED in'colour,Shall have corrosion fre£ gold Contact with 10 A rating* Shall be integrated with addressabel aanel thru Monitor Module^UL Listed) : Make Edward, Notifier, Ravel
Supply,installation,Testing and commissioning of Sounder cum Strobe with addressabel control Modules, UL Listed 9th Edition, Operates on 24VDC, 100db, Ceiling / Flush Wall Mount,Input Voltage : 24V DC (15-30V), Current: 100 mA @24V, Relative Humidity : 93 ± 2 @ 32 C, Operating Temperature : -10 to 50 C, Sound Level : 112 db +/- 5dB @ 30cm, Tone Type . Sweep Siren, Size : 126(W)*126(H)*55(D)mm Make Edward, Notifier, Ravel
Supply.installation,Testing and commissioning of Analog addressable Active Repeater Panel 32 bit processor.160 (40 X 4) Characters LCD display.Touch Keypad for user friendly operation.Remote silence and evacuate can be done from Repeater Panel.Remote Programming and control of any main panel in the network / system .RS 485 Communication for Standalone / Network Repeater.1000 Event storage with Real Time Clock.Battery low audio visual warning.One supervised Notification Appliance Circuits.One Form C relay for Common fire.USB 2.0 for PC Interface.
Supply & installation of Photo Lumicient EXIT Signage
Supply, installing, testing and commissioning of 2c x 1.5 sq. mm, PVC insulated FRLS Armoured copper cable for SLC Loop & Power Supply, confirming to IS standards and specifications..Complete as required as per technical specification.
EXTERNAL WATER SUPPLY
Supply,erection, testing and commissioning of factory assembled and tested electric motor driven three phase 415 Volt AC, 50HZ, Centrifugal type water pump set capable of delivering not less than 300 LPM of water as at minimum 30 mtr head and capacity not less than 5 HP comprising of heavy duty type centrifugal pump, Cast iron body with bronze impeller, casing ring, sleeves etc. coupled to TEFC electric motor of suitable RPM as recommended by manufacturer of pump by means of flexible coupling and mounted on a common fabricated MS base frame and Gl pipe heavy duty at suction and Gl heavy duty delivery pipe of suitable size as recommended by manufacturer upto suitable length at suction end and delivery connection to header with necessary Fittings. Note: - (i) Cost of Gl pipe heavy duty at suction and Gl heavy duty delivery pipe of suitable size as •ecommended by manufacturer upto suitable length at suction end and delivery connection to leader with necessary fittings shall be in overall cost quoted. ii) Cost of foundations as per manufacturer recommended drawings with Nuts , Bolts, Anti /ibration pads included in overall rates quoted.
M&L for construction of brick stone masonary valve pit / chamber of 900 MM X 600 MM X 1000 MM (internal dimensions) under mentioned sizes, all as shown in drawing No TD-573, including necessary excavation and earth work, PCC, plaster in CM 1:6 on inside and outside (above ground), MS angle iron 40 x 40x6.0 mm thick.
Supply and fixing in replacement Non return valve 80 mm Dia heavy duty PN-1.6 confirming to IS- 5312 both end flanged complete with neoprene rubber gasket, nuts , bolts, washers etc all as specified and directed.
Supplying , MS pipe of size 80mm dia header, cutting and fixing for position of pump, including all fittings, valves etc by welding/brazing/nuts, bolts or any other jointing process all as required at site or as specified and directed by Engr-in-Charge.
Supply and fixing , testing , commissioning flanged non rising type cast iron foot valve of size 80 mm suitable for pressure rating duly drilled holes for fixing by nuts and bolts, rubber gasket, washer complete ISI marked, confirming to IS all as specified.
Supply and fixing DOL starter 3 phase 5 HP, 415 Volts including electric connection complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply install,testing and commissioning LT panel outdoor type, dust and vermin proof totally enclosed platform mounted factory made (Protection class IP-54) double shutter gears front and rear frame work and 3.15 mm thick CRCA sheet duly painted with powder coated over two coats of redoxide primer and made of 40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 300 amps capacity aluminium bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable
(B) Outgoing :- (i) MCCB 63 A,4 Pole,35 KA,with adjustable thermal and magnetic settings - 03 Nos ( 02 FOR LIFTS AND 01 SPARE). (ii) MCB DP, 20 A, 1 OKA. -01 No. (C) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-l using 20 mm graded crushed stone aggregate ori top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Supplying, installation . coinmissing and testing of APFC panel indoor type of capcity 40 KVAR in 4 stages with microprocessor based APFC relay control, factory made of suitable size dust & vermin proof ,fully ventilated front side openable and fabricated out of MS CRCA sheet of 2.0 mm thick and mounted on 70 cms long legs of angle iron of size 50mm x50mm x 6mm out of which 30 cm shall be embedded in PCC foundation of PCC of 1:2:4 type B-l, 20 mm stone aggregate. The panel shall be painted with two coats o synthetic enamel paint over a coat of red oxide primer and provided with suitable size lugs and cable glands for incoming/ out going connections complete all as specified and directed. The panel shall be suitable to house and must be consisting of the following main parts in addn to any other part recommended by the panel manufacturer :- (1 ) Bus bar chamber with 4 Nos aluminium strip of 300 Amps rating and fixed on epoxy insulation complete with colour coding in colour code as per IE rules -01 set. (a) Main MCCB lOOAmps, 25 KA, 3 pole, with thermal & magnetic adjustable type type - 01 NO (for Incoming)
(d) One light duty fan in false ceiling. (e) Aluminium chequored plate (3 mm thick) as flooring. (f) Non stopbutton / in dependat operation. (g) Over load warning indicator both audio and visual type. (h) Front door, operations with a minimum time of 10 secods and up to a maximum time of 30 secods. (k) Car size shall be in conformity with IS - 3534 -1976 and body to be stainless steels of 16 gauge. (m) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (n) Specification piate. (o) Wire rope of 13 mm dia of suitable length and. (p) Other standard fixtures and fittings like sheaves, counter weights with guards, buffers, guides, sears, brakes, control panel, motor, locks, Governor, car operational panel, power, control and trailing cables complete. Testing:- Testing shall be done complete all as specified and as directed by Lift Inspector. The testing of lift is deemed to be included in the rate quoted.
(a) Fire man switch. (b) Automatic rescue device during power failure including mannual operation provision. (c) Emergency light (flouresant), alarm, and stop button in car with rechargeable arrangement. (c) Emergency light (flouresant), alarm, and stop button in car with rechargeable arrangement. (d) One light duty fan in false ceiling. (e) Aluminium chequored plate (3 mm thick) as flooring. (f) Non stopbutton / in dependat operation. (g) Over load warning indicator both audio and visual type. (h) Front door, operations with a minimum time of 10 secods and up to a maximum time of 30 secods. (k) Car size shall be in conformity with IS - 3534 -1976 and body to be stainless steels of 16 gauge. (m) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (n) Specification plate. (o) Wire rope of 13 mm dia of suitable length and. (p) Other standard fixtures and fittings like sheaves, counter weights with guards, buffers, guides, 3ears, brakes, control panel, motor, locks, Governor, car operational panel, power, control and.
(q) Lift shall be of ’Machine Room Type" i.e with machine room. (r) Drawing of lift shall be approve by GE before placement of order by the contractor. (s) Lift shall be inspected by the rep of Accepting officer as well as rep of State Govt authority before ssue of completion certificate by GE. (t) Nothing shall be paid on this account.
DG SET
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, 90 BHP engine as per IS: 10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity upto 62.5 KVA, (i) DIESEL ENGINE The Engine shall be Air cooled , oil lubricated,Exhaust silencer,Self seating arrangements and battery charger unit developing 1500 rpm suitable for above output of alternator at 40°C, 50 % RH & at 300 meter MSL and conforming to BS 5514, BS 649, IS 10000, Capable of taking 10% overloading for 1 hour after 12 hour of continuous operation. The engine will be fitted complete with all the required accessories like oil type air cleaner,Exhaust silencer suitable for canopy, Expansion bellow,Lube oil cooler,Full flow lube oil filter,Fuel filters(Pre and micro) in-line mono block fuel injection pump,mechanical Governor and fuel feed pump,Flywheel with starter ring and bell housing suitable for close coupling.Exhaust gas driven turbocharger, 12 Volt electric starter motor,
Battery charging alternator, microprocessor based controller fixed in power panel,Protection system for Low lube oil pressure,High cylinder head temperature,Fuel off solenoid,Initial fill of lube oil,Lube oil drain arrangement,Breather Pipe .AVM's etc complete all as specified. (ii)ALTERNATOR The Alternator shall be designed for output of 62.5 KVA ,415 volts,0.8 PF,50 Hz,3 phase 4 wire brush less self regulated,self excited with class "H "
insulation in SPDP enclosure floor mounted with ball bearings with end shields and confirming to IS 4722/BS 2613, suitable for tropical condition. (iii) FUEL TANK (62.5 kVA Air cooled) :-Draw out type fuel tank with Fuel guage air vent and drain plug arrangement with fuel filling cap with -lock & key arrangement is made on the canopy complete all as specified. (iv) BASE FRAME :- The base frame shall be Epoxy coated Sheet metal base frame suitable for mounting the Canopy structure iirectly on the channels.the cross members are designed in such way that it can house engine and alternator. Base frame will have provision to mount fuel tank and Battery. End channel will be of removal tank for removing the fuel tapk etc.Base frame will have provision for Lube oil drain hose and Breather hose. (v ) BATTERY (62.5 kVA) :- The Battery as per OEM spcifications and capacity with one set of connecting leads of 25 Sqmm size Copper cable as specified by Engineer in charge. (vi) EXHAUST PIPING :-
The exhaust piping shall be DG set in complete with Exhaust piping i.e Silencer is mounted and connected by means of MS pipe through flexible pipe to the engine manifold.Entire exhaust piping inside the canopy (cold zone) is insulated by means of ceramicwool and aluminium gladded. SPECIFICATION OF CANOPY (i) Acoustic Enclosure: The Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet 1 he silent canopy shall be of hut bolt type construction.Critical process of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1mm . Powder coating is done after seven tank surface preparation process of sheet metal.Canopy panel and doors shall have inside lining of Fire Retardant foam as acoustic material . Four hinged doors shall be provided to canopy one door shall have glass window for control panel along with following connected accessories/arrangements like Emergency stop button with wiring ,12 Volt Emergency light with wiring,4 nos Slam type Lock with key,4 Nos lifting hooks,
Viewing glass for control panel in the door,Rock wool stuffing in hot air zone,25 mm thickness FTD J2 model foam,3 Iran thickness polyurethene cross link tape provided in between top roof and hood,Rain cover plate for Exhaust pipe opening in the roof,All external fasteners used are SS and internal aie MS with Green Passivation,Exhaust piping system provided with tail pipe after silencer. (ii) Performance Parameters:-The average sound level, when measured in green field condition(ISO 3744or 8528 PT 10 ) at 1- meter distance from all four sides shall be less than 75-dbA averages as per CPCB nonns.The average stabilized hot air temperature rise within the canopy is maintained within 10 °C over and above ambient temperature. (iii) Testing:- Testing shall be done complete all as specified and as directed by Testing Officer. The fuel consumption for testing of DG is deemed to be included in the rate quoted.
Apex HVAC Services Pvt. Ltd.
M/s Innovative Coolings and Constructions
Saraogi Infrastructure
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .