| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹21.4 L+₹6.5 L (43.8%)Rejected-Finance AT 381 341 SARITA APARTMENT P O KHARAGPUR KHARIDA MAIN ROAD MIDNAPORE WEST WEST BENGAL 721301 | MEDINIPUR WEST | WEST BENGAL | 721301 | L2 | Rejected-Finance Higher bid value |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) KALAIKUNDA
CWE (AF) KALAIKUNDA, KALAIKUNDA AIR FIELD POST, DIST - WEST MEDINIPUR, WB - 721303
REPAIR/MAINT OF HT DISTRIBUTION LINE AND MISC E AND M WORKS
2022_MES_548094_3
8608/KKD/03/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AT AF STATION SALUA
Class E, Category b (ii)
2 documents required · 2 mandatory
₹500
GE (AF) KALAIKUNDA
₹30,000
Yes
12 Jan 2023
28 Nov 2022
28 Dec 2022
28 Nov 2022
26 Dec 2022
6 Dec 2022
Amount
Excavation in trenches Hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth complete all as specified & directed .
Returning and filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick with soils complete all as specified & directed .
Removing excavated soils not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified & directed .
Supply, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable punned down to 18 cm for under ground cable complete all as specified & directed .
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, flat, size 300mm x 180mm x 40mm complete all as specified & directed .
Supply and fixing in replacerment of GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified & directed .
All as per ser item No 06 but here-in-before 80 mm bore complete all as specified & directed .
Taking out old UG Cable of any size and description, Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 (E), grade cross sectional area 95 sq. mm 3 core complete all as specified and as directed .
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed..
Material and labour for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 Volts complete all as specified and as directed .
S & F in replacement of triple pole mechanically operated mounted on insulator and steel frame with operating mechanism air break gang operated switch and DO fuse, worked ground for current rating up to 200 Amps 11000 volts complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamalled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps, bolts, and nuts of approved size for HT 25X20 cm complete all as specified and directed.
S& F Anti climbing device comprising spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L for replacement of Cross arms, bracings, supports, clamps and black plates fabricated from structural steel sections incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and incl of primer on coat, and under coat and one finishing coat of paint complete all as specified and directed.
Supply and fixing LT bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 25 KVA to 160 KVA complete all as directed and specified .
All as per item No 17 here-in-before but for transformers of capacity 200 to 400 KVA complete all as directed and specified.
Supply and fixing HT bushing including heat resistance gasket, brass spindles, nuts, bolts, washers for transformers of capacity 25 KVA to 160 KVA complete all as directed and specified .
All as per item No 17 here-in-before but for transformers of capacity 200 to 400 KVA complete all as directed and specified .
Material and labour for replacement of silica gel of air breather filled complete for transformer of capacity 25 to 500 KVA complete all as directed and specified
Supply & Fix silica gel breathers assembly filled complete for transformer cap 25 to 125 KVA complete all as directed and specified
All as per item No 22 here-in-before but for transformers of capacity 150 to 400 KVA complete all as directed and specified
M&L in repair for Filteration and dehydration of HV grade transformer oil of distribution and Power transformer of out door type of 11/.433 KV, 25 KVA to 400 KVA min three cycle to achive die elctric strength of 40 KV to 60KV for 1 Minute at 4 mm gap as per relevent IS complete all as specified and directed. Note : (i) Filteration to be done by Dehydration machine till the desired level of dielectric strength of tranformer oil comes to 60 KV . (ii) Each sample of oil will be tested with a transformer oil test machine at site in presence of concerned JE's/Engr-in-charge and test result will be submitted accordingly). (iii) Centrifugal machine with all T&P and Testing Machine , oil required shall be arranged by contractor. (iv) Oil required for topping up the transformer oil will be measured and paid seperately in relvent item.
Supply & top up and filling of transformer oil suitable for Voltage stablizers, transformer, OCB, etc. confirming to IS and dielectric strength less than 60 KV in sealed containers of Make : Power Oil/Indian Oil/Universal or equivalent complete all as directed and specified
Disconnecting and takingout,repairing existing APFC HT 11 KV for seviceable & reuse from housing and cleaning,rubbing and overhauling the mechanical parts and making serviceable of local/remote electrical operation of the panel including Greasing,oiling,replacement of UNSV Trip coil,breaker charging motor,gear pinion,roller switch and reassembling the same after replacement of spare parts as required including testing complete all as specified and directed (Note : All Spares parts of panel will be Measured and paid sepratly under respective items of this schedule here in after as supply only)
Supply only in replacement of MCCB 125 A- 4 pole complete all as directed and specified .
Supply only in replacement of MCB 63 A - 3 pole complete all as directed and specified .
Supply only in replacement of Auxiliary contact block complete all as directed and specified .
Supply only in replacement of Contactor AC operated complete all as directed and specified .
Supply only in replacement of fuse link (HRC) complete all as directed and specified .
Supply only in replacement of LED indicator lamp complete all as directed and specified .
Dismantling of LT Voltage stabilizer 150-400 KVA carefully & opening for strip inspection, & replacement of worn out defective parts such as relay ckt , dimmer ckt ,coil , fuse unit, fuse carrier assembly, etc. to the entire satisfaction as to make it fully functional & filling /dehydratation of oil appropriate level having including cleaning of the chamber complete all as directed . Note:- stabiliser oil shall be meaured and paid separately.
M&L for disconnection of complete incomming and outgoing HT cables & servicing of VCB 11 KV 400/630 Amps any make and type complete calibration of relay ( earth fault and over current ) and check out tripping system at desired current rating incl replacement of minor fitems such as No volt coil , treminals , wires for wirings of panels and indicator lamps , fuse links etc incl lubricating material like grease / petrolium jelly shall be icl in quoted rates and after servicing reconnection of cables and testing panel on load complete all as specified and directed. (Note : All Spares parts of panel will be Measured and paid sepratly under respective items of this schedule here in after as supply only)
Supply only in replacement of Vacuum Interrupture complete all as directed and specified .
Supply only in replacement of Closing Coil complete all as directed and specified .
Supply only in replacement of Tripping Coil complete all as directed and specified .
Supply only in replacement of Breaker Auxilaiary Switch complete all as directed and specified .
Supply only in replacement of Limit Switch 4 terminal complete all as directed and specified .
Supply only in replacement of Phase Spout complete all as directed and specified .
Supply and fix of HT Cable Route Indicator made out of MS Plate 30x20x5 mm thick fixed on 1.5 mtr height angle iron of size 20x20x3mm duly painted with two coat of synthetic enamel blue colour paint over a coat of red oxide primer and written as 'HT Cable' in Red paint letters of 2 inch size, The Cable route indicator shall be embeded in PCC (1:3:6) of size 300x300x300mm (20 mm grade) with fine finish and to be fixed complete all as directed and specified .
Supply and spreading gravel stone aggregate of size upto 40 mm evenly under GO/DO structure after cleaning the surfacecomplete all as directed and specified . (Brick work all around the structure as directed by Engg-in-charge are included in over all rates quated)
S&F in replacement of Copper strip 32X6 mm for roof conductors and bracing to down conductors above ground complete all as directed and specified .
S&F in replacement of Copper strip 20 x 3.15 mm for roof conductors and bracing to down conductors above ground complete all as directed and specified .
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth plate not less than2.25 M in deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to copper earth strip 20x 3 mm by means of bolts, nuts, check nuts and washers of Copper and connected to earthing test point all as specified and directed including necessary earth work in any type of strat and PCC 1:3:6 type B1 for chamber and RCC chamber cover 50 mm thick in lieu of CI cover and copper strip protected by 40 mm GI pipe medium grade complete inlcuding filling of agrictulture sand brought from outside defence land for earth pit complete all as directed and specified .Excavation and removal of excavated soil and filling of agriculture sand brought from out side defence land shall be included in the overall rate quoted. No extra payment shall be paid Note:- (a). The quoted rate includes the rate of Magnesium Sulphate of 40Kg per earth pit poured with salt and charcoal.
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 25 to 400 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as directed and specified .
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 11/0.433 KV transformer complete all as specified and directed.
M&L for detecting of fault in 11KV (E) HT cable of any size(within 1-3 km length) , 3 core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed and specified . Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & Jointing kit shall be measured & paid separately. (iii) As the work is releated to maintenance, the work of fault detection has to be carry out on Priority and on requirement basis as on occurance of fault within 24 hrs so as to rectify the fault and to restore the electric supply of stn. If contractor delay the job, necessary panlty at the rate of Rs 1000.00 per hrs (after 24 hrs) will be impose on contractor.
Lotas Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .