Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹4,549
Closing Date
22 Apr 2024, 12:00 pmClosed
EE ED-II ND
BSNL ED-II, Eastern Court, Janpath New Delhi-110001
Dismantling shifting of all electrical items like fittings fans ACs DBs AFD system, AC plant etc from the 2nd floor at Sanchar Bhawan New Delhi Ch. to ARMO of EI and fans
2024_BSNL_193523_1
01/NIT/E-Tender/2024-25/ED-II
Open Tender
Electrical Works
Item Rate
10 days
Sanchar Bhawan
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash) O/o CGM NTR BSNL
₹4,549
23 Apr 2024
16 Apr 2024
23 Apr 2024
16 Apr 2024
22 Apr 2024
16 Apr 2024
Dismantalling of the complete wiring/ conduit/ light/ fittings/ ceiling fans/Distribution board (DB's) etc complete from the 2nd floor (Other than Committee and commissioning room) with following material complete with disconnection, collection at common location and shifting to the safe place at ground/basement floor etc as reqd complete in all respect (as per the instructions of the Engineer-in-charge)
a) 1.5/2.0 TR Split AC units-15 Nos b) 1.5 TR window AC units-03 Nos c) Water storage geysers-01 Nos d) Fittingts of all types 1x40 /2x40/2'x2'LED panels -133 Nos e) Pedstal fans-04 f) Fresh air fans /Wall fans-20 g) Wiring and conduit available at above locations h) DBs-03 Jobs
Dismantalling of the complete wiring/ conduit/ light/ fittings/ ceiling fans/Distribution board (DB's) etc complete from the 2nd floor Committee and commissioning room) with following material complete with disconnection, collection at common location and shifting to the safe place at ground/basement floor etc as reqd complete in all respect (as per the instructions of the Engineer-in-charge)
a) 1.5/2.0 TR Cassette AC units-06 Nos b) 1.5 TR Tower AC units-04 Nos c) UPS 5.5 Kva -02 Nos with battery sets d) Fittingts of all types 1x40 /2x40/2'x2'LED downlighters -68 Nos e) Ceiling fans-NIL f) Fresh air fans /Wall fans-03 g) Wiring and conduit at above locations h) DBs-02 Jobs
Dismantalling of the complete AHU's each of Cpacity 33 TR complete from the 2nd floor AC plant room with following all accesories and components complete with disconnection, cutting of AHU in peices to facilitate transport and shift to Ground/basement floor ,collection at common location and shifting to the safe place at ground/basement floor etc as reqd complete in all respect (as per the instructions of the Engineer-in-charge)
a) 33 TR AHU-02 Nos b) AC GI ducting alongwith members etc -approx 275 sq mtr c) Supply air diffusers size 2'x2'- 05 Nos d) Supply air diffusers size 1'x1'- 04 Nos e) Return air diffusers size 2'x2'-04 Nos f) Return air diffusers size 1'x1'-04 Nos g) Supply air grills size 2'-6"x7-1/2"-10 Nos h) Supply air grills size 2'-6"x5"-06 Nos i) Return air grills size 3'-6"x9"-16 Nos
Dismantalling of the following size Al/Copper armoured/unarmoured powert cable complete with disconnection, dismantalling , collection at common location and shifting to the safe place at ground/basement floor (as per the instructions of the Engineer-in-charge) etc as reqd complete in all respect.
upto 120 sqmm
120 sqmm to 300 sq mm
Dismantalling of the exisitng Automatic Fire detection system complete with Cabling, detectors, RI, MCPs , Hooters etc complete with disconnection, dismantalling , collection at common location and shifting to the safe place at ground/basement floor etc as reqd complete in all respect (as per the instructions of the Engineer-in-charge)
Dismantalling of the exisitng LT panelcomplete with cables with disconnection, dismantalling , collection at common location and shifting to the safe place at ground/basement floor (as per the instructions of the Engineer-in-charge) etc as reqd complete in all respect. (From Control room )
Less on a/c dismantalled material to be credited to the agency like conduit/wiring/switch boards/DBs with MCBs/AC ducting/grills/diffusers etc (Except Fire detectors, RI, MCP, Hooters, speakers, ACs, fans, light fittings , LT panel, UPS/Inverter with battery sets, AHU and Power cables) (as per the instructions of the Engineer-in-charge) etc as reqd complete in all respect.
SCOPE OF WORK:- 1. No material shall be supplied by the department. 2. Nothing extra shall be paid on account of cartage. Suitable arrangement should be make by the firm to attend the complaint with in 2 Hours after receiving the complaint. For this purpose the contractor shall have to provide minimum 1 No. Skilled and 1 No. Un-skilled worker between 09:00 AM to 06:30 PM at Sanchar Bhawan (If more man power is required at any stage, same shall be provided by the Agency without any extra cost) from Monday to Saturday. Necessary arrangement should be made by the firm for attending the complaint throughout 24 hours. The Contractor should quote their rates accordingly. Note:- 1. The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules. 2. The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit. 3. Servicing Scrap items will be credited to the firm. The rate may be quoted accordingly. 4. Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required. 5. If annual maintenance contract charges are required to be quoted as per SOW, basic charges should be shown in column 4 & the Goods and Service Tax (GST) in column 7 to 12. 6. The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services. 7. In case, dealer is registered under compounding scheme or any rule/notification where the BSNL is not eligible for input tax credit then the bidder should not disclose any amount in column 7 to12 & 14. 8. % age Rate of FF & Packing should be shown of basic unit price excluding all taxes & charges (i.e. as %age of col.4). 9. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc. 10. Bidder must mandatorily mention HSN & SAC numbers. 11. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST. Declaration by Bidder: 1. We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date. 2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws.
pawan enterprises
kashyap electricalsd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .