| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.4 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹31.6 L+₹2.4 L (8.33%)Rejected-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹32.3 L+₹3.2 L (10.9%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹34.4 L+₹5.2 L (18.0%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-4 | Rejected-AOC L-4 | |
| 5 | Rejected-Technical 16 20 GALI NO 7 8 SWAROOP NAGAR EXTENSION DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | - | Rejected-Technical No, not enlisted in eligible category |
Tender Value
Refer Docs
EMD Value
₹70,200
Closing Date
4 Nov 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR MAINT OF EXTERNAL ELECTRIFICATION, MAINT OF TRANSFORMER, 33/11 KV VCB, SERVO STABILIZER AND OTHER CONNECTED WORK AT DRDE GWALIOR AND REPAIR REPLACEMENT OF OLD UNSERVICEABLE LT PANEL BOARD, REPLACEMENT OF DEFECTIVE MCCB, PAINTING OF PANEL BOARD
2023_MES_622227_1
GE/RND-71/GWL/2023-2024
Open Tender
Civil Works
Item Rate
270 days
Agra and Gwalior
Class-D, Cat - b(i), b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹70,200
Yes
17 Jan 2024
7 Oct 2023
6 Nov 2023
7 Oct 2023
4 Nov 2023
21 Oct 2023
Amount
Disconnecting & taking out non functional VCB and SF-6 Braker of any description and any make of rating 33 KV,1250 Amps dismantling / opening of the VCB / SF-6 Braker for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed. Note :- 1. The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as `supply only ‘
Supply only following spare parts for 33 KV VCB.
Micro switch
Motor cut of limit switch
Closing coil 110 VDC
Triping coil 110 VDC
Segment gear Assembly (Full Teeth-Big )
Triping Half shaft
Trip Catch with linkage assembly
Spring charging motor assembly 230 VAC
Motor Gear Box Assembly.
Closing Half shaft
Auxiliary switch assly
Ratchet wheel with key & Set of pawls with pin
Motor contractor
Limit switch
Vacuum Interceptor ,Make:-CG,Schnider,Siemens
Taking down the existing IDMT relays (two nos over current and one no earth falult relays fixed in 33 KV HT Panels for primary and secondary injection and calibration of all the relays and setting the relay tripping timings in advance to the feeding sub-station to ensure pockets vise installation of various relays in position with complete control and test and trial Note :- (i) The primary injection kit shall be arranged by the conductor. (ii) The DC supply for relay testing shall be arranged by the contractor. (iii) The contractor shall be prepare the relay adjustment and tripping timing chart in follow up fashion and submit it to complete all as specified and directed.
Disconnecting and taking down the unserviceable/damaged/non operational existing lightening arrestor of 33KV Switching yard and supply , fixing & testing and commissioning of new lightening arrestor 33KV, 10KA suitable for 33KV and maximum voltage of 36KV for (MRS) with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work and all as specified and directed. Make : Obleium/ jaipuriya/pactil
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 400 Amps of 33 KV and supply and fix new air break switch gang operated Triple pole mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch . all as specified and directed. Make: Jaipuria Brothers/Atlas/Pactil/HEI/ECE Calcutta/MEC Trivendrum
Taking down existing unserviceable Drop out fuse set outdoor type upto ratio 400 Amps of 33 KV and supply and fixDrop out fuse set mounted on insulator and steel frame complete all as specified and directed. Make:- Jaipuria /pactil /atlas
Disconnecting GOD of capacity 33 KV, dismantling of GOD for complete repair & overhauling and checking the serviceability of spares and operating mechanism and replacement of defective/worn out spare parts for making the GOD functional including reassembling of operating mechanism oiling & greasing of moving parts, fine setting of mechanism, making the GOD perfect operational in manual mode complete all as specified and directed. Note :- The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as `supply only ‘
Supply only following spare parts for 33 KV GOD.
Male contact
Female Contact
Tinned copper flexible jumper
M S Carrier
Back Connector plate
Disconnecting and taking out old unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of new digital Ammeter size as per side required of range For suitable for panel, 11 KV HT VCB Complete all as specified and directed.
Disconnecting and taking out existing unserviceable Potential transformer (PT) of any description and in any position and supply, installation, commissioning and testing of 11 KV single phase out door oil cooled potential transformer all as specified and directed.
Disconnecting & taking out non functional VCB/OCB of any description and any make of rating 11 KV, 400 Amps to 800 Amps dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing Complete all as specified and directed. Note: - The quoted rates of the contractor includes for replacmen of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as supply only.
Supply only following spare parts for 11 KV VCB 400/630 Amps capacity of any make.
Isolating Contacts . Make :- CG,Schnider,Siemens
Closing shaft. Make:-CG,Schnider, Siemens
Triping shaft. Make :-CG,Schnider,Siemens
Big Gear Assembly. Make :-CG,Schnider,Siemens
Small Gear Assembly. Make:-CG,Schnider,Siemensr
Motor Cut off limit switch. Make:-CG,Schnider,Siemens
Micro switch assembly. Make:-CG,Schnider,Siemens
Breaker Control switch. Make:-CG,Schnider,Siemens
Spring charging Motor 230 VAC. Make :-CG,Schnider,Siemens
Segment Gear Assembly (squir type). Make:-CG,Schnider,Siemens
Trips catch assembly. Make:-CG,Schnider,Siemens
Bus bar support insulator. 61mm dia. Make:-CG,Schnider,Siemens
Epoxy Bussing insulator for 11kv. Make:-CG,Schnider,Siemens
ON/OFF push butten Assembly. Make:-CG,Schnider,Siemens
Charge Dischasge indicator assembly. Make:-CG,Schnider,Siemens
Indicating lamps Blue 230 VAC spring charging. Make:-CG,Schnider,Siemens
Indicating lamps Red,Yellow,110 VAC. Make:-CG,Schnider,Siemens
Indicating lamps Blue 110 VAC. Make:-CG,Schnider,Siemens
CGI 14N Numerical Relay CGL. Make :-CG,Schnider.L&T,Aroba)
Closing / Trip coil Make:-CG,Schnider,Siemens
Spout busing upper & lower 11kv 400 to 800A with CC parts. Make:-CG,Schnider,Siemens
CRC Spry for lubricant
Vacuum Interceptor. Make:-CG,Schnider,Siemens
Decorbonising\cleaning complete HT 11 KV 3 Phase bus bar chamber of HT panel electrical connection rods complete HT VCB switch gear arrangement incoming and out going breaker after removing complete monoplast putty cleaning with CTC solution and ensure proper decorbonising refixing the same after applying beacon (red) insulating compound to the spout checking all connections tightening the nut and bolts washers of incoming and out going connections Complete all as specified and directed. Note : The rate is inclusive for replacement of worn out bolts nuts & washers, lugs, glands etc
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 200+100\5+5 A having protection core class 5P 10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking caP of 13.1 KV for 1.0 second all as specified and directed.
Supply and fixing in repair battery 12v 150 AH Lead acid low maintanance complete all as specified and directed. Make :- EXIDE/SF/TATA/AMCO
M & L in Replacement jointing and testing for outdoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of95 to 120 Sqmm 3 core.complete material and labour including cutting the faulty outdoor end termination joint of any description and in any position.
M & L in Replacement jointing and testing for Indoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of 95 to 120 Sqmm 3 core.complete material and labour including cutting the faulty outdoor end termination joint of any description and in any position
M & L in Replacemente Jointing and testing of Straight through heat shrinkable joint suitable for 11 KV, XLPE/PVC insulated cable size of 95 to 120 sqmm complete material and labour including cutting the faulty straight through of any description and in any position.
M & L in Replacemente Jointing and testing of heat shrinkable end termination joint suitable for 33 KV, XLPE/PVC insulated cable size of 120 sqmm complete material and labour including cutting the faulty end termination of any description and in any position.
Removal of existing broken/damaged PCC duct over of any description and Material & labour for duct cover of pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) of size 430mm x 600mm x 60mm thick, cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways with 02 Nos 12mm dia MS round bar handle with and including necessary work complete all as specified and directed.
Removal of old stone aggregate cleaning screening and relaying at same or another location complete all as specified and directed.
M&L for 40 to 63 mm graded stone aggregate of black trap / granite / basalts spread in layers not exceeding 25cm thick, & well rammed to a true surface removal of old stone aggregate cleaning screening cum and relaying at same or another location. Complete all as specified & directed
Disconnecting defective indoor/outdoor type transformer of various capacities 200 KVA to 315 KVA from HT/LT sides drain out transformer oil completely and keep storing the oil in suitable clean container (to be provided by the contractor) opening Top Cover and lifting assembly and core assembly carefully and checking the condition, refilling the transformer oil completely after necessary repair, and fixing the top cover complete all as specified and directed .Note:- (a) Rewinding of the transformer shall be measured and paid separately. (b) In case of major repairs/replacement in transformer which cannot be undertaken at site the transformer shall be shifted to civil workshop and the quoted rate shall be exclusive of this aspect.c) Dismantling of core and repairs shall be measured and paid separately.d) Shifting of transformer shall be measured and paid separately. Complete all as specified and directed.
All as per item Ser No 23 above but transformer of capacity exceeding 400 KVA but not exceeding 500 KVA.
All as per item No 23 above but for transformer of capacity 1000 KVA.
Dismantling and taking out the existing unserviceable circuit tap changer assembly and supply and fix off circuit tap changer assembly suitable for any make of 100 KVA to 500 KVA transformer with 7 tapping position including opening top cover breaker etc, complete all as specified and directed. Note: - Contractor is solely responsible for making good of any damage to transformer during tap changing operation without any extra cost.
Supply, filling and topping up the transformer/OCB’s with new transformer oil duly filtered with filtration plant complete all as specified and directed.
Filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 60KV. Note :- (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b) The contractor shall ensure to Avoid wastage at transformer oil. (c) The contractor fully responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.
Supply and fixing silica gel complete all as specified and directed.
Supply only insulation material PCB electrical grade such as barriers coil to coil insulation block and rings insulation cylinders, ebonite sleeves Complete all as specified and directed.
Removing and refixing of new HT & LT coils/strips, disconnecting the 200 KVA to 315 KVA 11KV/430Volts indoor/outdoor transformer HT/LT side, drain out transformer oil completely, storing the oil in suitable container/barrels properly cleaned ones (to be provided by the contractor) lifting the transformer from the sub station and shifting to civil workshop and opening the top cover. and Taking out core Assembly , Opening HT/LT brush damage coil opening / removeing the save and fixing New HT/LT copper coil Made out of proper size suitable for DPC copper wire of high quality suitable rating sleeve insulating materials like varnish etc, complete after necessary arrangement with new coils, necessary insulation spacing blocks, runners and proper refixing of core. Note:-(i) HT & LT copper coil/strips and insulation material PCB electrical grade such as barriers coil to coil insulation block and rings insulation cylinders, ebonite sleeves shall be measured and paid separately under relevant item schedules. (ii) The rate quoted is deemed to be included for cutting / chipping of RCC and for the minor grill work such as PCC, plastering foundation work. (iii) Proper drying has to be done in drying chamber after drying, taking the core coil assembly, filling the filtered transformer oil having good dielectric strength, replacement of suitable size rubberized cork gasket, bolts and nuts etc complete by fixing top cover, conservator etc, through cleaning and painting to the transformer with good quality paint complete and testing complete at civil workshop. (iv) Transformer oil shall be measured and paid separately under relevant item of schedule. (v) Installation of transformer, testing and connecting the both HT & LT cables, commissioning of transformer after checking voltage and all loading the transformer to the full load all as specified and directed. (vi) The cost of coil will be inclusive of varnish sleeving and insulating material.
All as per item No 31above but transformer of capacity exceeding 400KVA but not exceeding 500 KVA.
Supply only new LT copper strips Coil made out of proper size of DPC copper strips super enameled of high quality matching with the existing impedances and insulation for 100 to 1000 KVA transformer Complete all as specified and directed.
Supply only new HT copper coil made out of proper size DPC copper wire super enameled of higher quality matching with the existing impedance and insulation for 100 to 1000 KVA transformer. Complete all as specified and directed.
S&F in replacement HT(11 KV ) bushing assembly including brass stud nuts washers insulators etc. suitable for indoor/outdoor transformer of capacity 100 to 1000 KVA Complete all as specified and directed.
S&F in replacement 12mm dia LT bushing assembly including brass stud nuts, check nuts washers oil seal insulators etc Complete all as specified and directed:-
All as item No. 36 above but of size 16mm dia.
All as item No. 36 above but of size 20mm dia.
All as item No. 36 above but of size 40mm dia.
Inspecting/Checking for operation of the servo voltage stabiliser 400 KVA to 1000 KVA, servising /maintenance up to satisfactory level, so that the constant output voltage (For single phase 230-240 Volt & for 3 phase 415 volt with +- 2.5% volt correction factor ) can be supply to labs,in respective incoming voltage 360 Volts to 470 Volts with any variation in phase to phase. Note :- Any unserviceable part to be replaced shall be measuered and paid separately as supply only.
Supply only Servo digital panel
Supply only Servo motor
Supply only Voltmeter 96mm up to 500 Volt
Supply only Amp meter 96 mm
Supply only RC
Supply only Carbon brush
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded with 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip 32x6mm by means of nuts, bolts and washers. GI strip laid in 40 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with comprising of following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion:- (a) GI strip 32x6 mm upto 7.5 meter. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil, PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 using 20mm graded stone aggregate, exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 using 20mm graded stone aggregate, reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earthing complete with copper plate electrode 600mmx600mmx3.15mm thick buried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper earth strip 32x6mm by means of nuts, bolts and washers. Copper strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a) Copper strip 32x6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia mild steel TMT bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 200 Amps of 11 KV and supply and fix new air break switch gang operated Triple pole ( 9Insulator ) mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch . all as specified and directed Make: Jaipuria Brothers/Atlas/Pactil/HEI/ECE Calcutta/MEC Trivendrum.
Disconnecting, taking out and removing old existing unserviceable underground, HT 11 KV cable of any description and in any position complete including taking down protection pipe etc all as specified and directed.
Supply, laying , jointing & testing 11 KV (Earthed) , aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having following cross sectional area 95 Sqmm 3 core complete all as specified and directed.
Demolition for cement concrete in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed
M&L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete making good as per existing surface etc complete all as specified and directed .
M & L in Replacement, laying & jointing GI water tubing, 100 mm bore,light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed.
Excavation in trenches in soft loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested Complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point Complete all as specified and directed.
M&L for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection. Complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary manual of 100 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed.
Supplying, laying, jointing & testing of 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 95 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole or under floor /road or laid in trenches including taking out old unserviceable cable complete all as specified and directed.
All as per ser item No. 56 here-in-before but 70 Sqmm 3.5 Core.
All as per ser item No. 56 here-in-before but 50 Sqmm 3.5 Core.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable, complete all as specified and directed.
M&L for GI pipe (light grade) with all fittings laid in trenches/wall complete for protection UG cable when crossing the road of size 40 mm bore including taking out old unserviceable pipe complete all as specified and directed.
M&L for GI pipe (light grade) with all fittings laid in trenches/wall complete for protection UG cable when crossing the road of size 50 mm bore including taking out old unserviceable pipe complete all as specified and directed.
M&L for boring of holes by manually / machine under road, pavement, hard standing by trenches for laying of 40 mm GI pipe for cable laying, Complete all as specified and directed.
S&F MCCB TPN 630 Amp,36 KA Amp 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable complete all as directed.
S&F MCCB TPN 400 Amp,36 KA 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable complete all as directed.
S&F MCCB TPN 250 Amp,36 KA 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable complete all as directed.
S&F MCCB TPN 160 Amp 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable Complete all as specified and directed.
S&F MCCB TPN 125 Amp 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable Complete all as specified and directed.
S&F MCCB TPN 63 Amp 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable Complete all as specified and directed.
S&F MCCB TP 250 Amp,36 KA 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable Complete all as specified and directed.
S&F MCCB TP 160 Amp 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old unserviceable Complete all as specified and directed.
S&F MCCB TP 125 Amp 415 Volts, 50 Hz suitable as per existing sample and connection with copper lugs including taking down old one Complete all as specified and directed. Make: HAVELLS Load line/L&T d sine /Legrand
S&F MCCB TP 63 Amp 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable. Complete all as specified and directed.
S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as directed.
S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as directed.
S&F MCB SPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as directed.
M & L for preparation old painted surface of steel material of any description, over 10cm in width or girth apply one coat of synthetic enamel paint complete all as specified and directed.
S & F LED indicating light ( R,Y,B ) of LT panel suitable for 230 V ,50 Hz as per existing sample including taking out the old unserviceable. Complete all as specified and directed.
S & F steel lock for LT electric panel in place of old unserviceable lock including taking down the old one as per existing sample complete all as specified and directed.
S & F door hinges for LT electric panel in place of old unserviceable lock including taking down the old unserviceable as per existing sample complete all as specified and directed.
Supply installation testing and commissioning of street light panel single phase suitable for max load of 5 KW with nature switch sensor and hensel enclosure conforming to IP 66,25 amp MCB suitable and including mounting on wall/pole for control street light/aviation light including connections with the cable gland aluminium lug, MS fixing clamp ,cutting the hole in wall of suitable size including taking out the old main switch/MCB/MCCB complete all as specified and directed. Make - SWADEEP-66-5KW1P or equivalent as approval by GE.
Supply installation testing and commissioning of street light panel three phase suitable for max load of 5 KW with natureswitch sensor and hensel enclosure conforming to IP 66,25 amp per phase MCB suitable and including mounting on wall/pole for control street light/aviation light including connections with the cable gland aluminium lug, MS FIixing clamp ,cutting the hole in wall of suitable size including taking out the old main switch/MCB/MCCB complete all as specified and directed. Make - SWADEEP-66-5KW3P or or equivalent as approval by GE.
S & F TPN DBs double door vartical type suitable for incomer MCCB 125 Amps TPN as incomer and 12 Nos MCB SP as outgoing 415 Vol,50Hz including taking down old unserviceable complate Note:- Cost of MCCB and MCB will be measured and paid seperately.
S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc including taking down old unserviceable complete all as specified and directed.
S&F MCB single pole and neutal,32 Amp to 40 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc including taking down old unserviceable complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded with 15cm thick layers of common salt and charcoal dust starting from ground below with 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4mm dia by means of Copper nuts, bolts and washers. GI wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with comprising of following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire 4 mm dia upto 7.5 meter. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil, PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 (using 20mm graded stone aggregate) reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
GUPTA ENGINEERING WORKS
Aaradhya Ables Group
Pradeep Bros
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .