Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹46.7 L+₹3.2 L (7.35%)Rejected-Finance | L2 | Rejected-Finance Being Not the Lowest Tenderer | |
| 3 | L3₹47.7 L+₹4.2 L (9.73%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Being Not the Lowest Tenderer | |
| 4 | L4₹48.2 L+₹4.7 L (10.7%)Rejected-Finance 109 D ALLAI SALT COMPOUND OLD LAKSHMI THEATRE KRISHNAPURAM COONOOR 643102 THE NILGIRIS | COONOOR | THE NILGIRIS | TAMIL NADU | 643102 | L4 | Rejected-Finance Being Not the Lowest Tenderer | |
| 5 | L5₹49.7 L+₹6.2 L (14.3%)Rejected-Finance C 150 ADG P CHENNAI | L5 | Rejected-Finance Being Not the Lowest Tenderer |
| Sl No | Description | Qty | Unit | shalom constructions L1 | S.RAMACHANDRAN L5 | A.GOVINDARAJ L2 | K.AYYAPPAN L4 | T C KARUNANITHI L6 | SREEKRUPA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement including taking out old unserviceable panel board with accessories such as MCCBs complete with following cables all as specified and directed. (9 Mal lake view sub station & Lake view near High Mast light)
(a) INCOMING:-
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 36 KA, 250 Amps 415 Volt - 1 No
(b) OUTGOING
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 200 Amps 415 Volt - 1 Nos
(ii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 160 Amps 415 Volt - 1 Nos
(iii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 100 Amps 415 Volt - 2 Nos
(iv) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 63 Amps 415 Volt - 2 Nos
(v) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 40 Amps 415 Volt - 2 Nos
(vi) Astronomical time switch for 24 Hrs setting-1 Nos.
(vii) 2 Pole power contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type-1 Nos.
(c) 500 Amps aluminium busbar for phase and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set
(d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos
(e) LED type Indication lamp 415 Volts Set of three - 1 Set
(f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.
(ii) Panels shall be placed above 0.6 mtr from ground level.
(iii) Outgoing MCCBs shall be fed with solid busbar connectors.
(iv) Cables shall be terminated using gun metal /SS glands.
(v) Location - Various places at Wellington station. | 7 | JOB | 1,31,000 ₹9,17,000 Lowest | 1,35,000 ₹9,45,000 | 1,33,000 ₹9,31,000 | 1,47,000 ₹10,29,000 | 1,48,000 ₹10,36,000 | 1,42,000 ₹9,94,000 |
| 2.00 | MCCB 4 pole, 415V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 6 | EACH | 9,900 ₹59,400 | 12,600 ₹75,600 | 12,000 ₹72,000 | 8,000 ₹48,000 Lowest | 12,380 ₹74,280 | 10,500 ₹63,000 |
| 3.00 | MCCB 4 pole, 415V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 12 | EACH | 10,900 ₹1,30,800 | 13,200 ₹1,58,400 | 12,500 ₹1,50,000 | 9,000 ₹1,08,000 Lowest | 13,422 ₹1,61,064 | 12,800 ₹1,53,600 |
| 4.00 | MCCB 4 pole, 415V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 14 | EACH | 11,900 ₹1,66,600 | 15,000 ₹2,10,000 | 13,500 ₹1,89,000 | 10,000 ₹1,40,000 Lowest | 14,633 ₹2,04,862 | 13,500 ₹1,89,000 |
| 5.00 | MCCB 4 pole, 415V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed. | 1 | EACH | 21,900 ₹21,900 Lowest | 25,200 ₹25,200 | 25,000 ₹25,000 | 30,000 ₹30,000 | 28,731 ₹28,731 | 28,000 ₹28,000 |
| 6.00 | MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 8 | EACH | 8,900 ₹71,200 | 9,000 ₹72,000 | 11,000 ₹88,000 | 8,000 ₹64,000 Lowest | 12,363 ₹98,904 | 9,000 ₹72,000 |
| 7.00 | MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 12 | EACH | 9,900 ₹1,18,800 | 10,200 ₹1,22,400 | 12,500 ₹1,50,000 | 9,000 ₹1,08,000 Lowest | 13,685 ₹1,64,220 | 9,500 ₹1,14,000 |
| 8.00 | MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 9 | EACH | 10,900 ₹98,100 | 10,200 ₹91,800 | 13,500 ₹1,21,500 | 10,000 ₹90,000 Lowest | 14,112 ₹1,27,008 | 11,200 ₹1,00,800 |
| 9.00 | Supply and replacement of 25 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed
Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete | 510 | RM | 298 ₹1,51,980 | 420 ₹2,14,200 | 310 ₹1,58,100 | 315 ₹1,60,650 | 280 ₹1,42,800 Lowest | 280 ₹1,42,800 Lowest |
| 10.00 | Supply and replacement of 35 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed
Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete | 490 | RM | 410 ₹2,00,900 | 510 ₹2,49,900 | 450 ₹2,20,500 | 465 ₹2,27,850 | 375 ₹1,83,750 Lowest | 450 ₹2,20,500 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
15 Jul 2025, 6:00 pmClosed
GE WELLINGTON
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIRS/ REPLACEMENT LT PANEL, UG CABLES AND CONNECTED ITEMS WELLINGTON STATION UNDER GE WELLINGTON
2025_MES_716279_1
8123/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
WELLINGTON
As per Tender Document
8 documents required · 8 mandatory
₹500
GE WELLINGTON
₹88,000
Yes
10 Oct 2025
23 Jun 2025
22 Jul 2025
24 Jun 2025
15 Jul 2025
8 Jul 2025
Amount
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement including taking out old unserviceable panel board with accessories such as MCCBs complete with following cables all as specified and directed. (9 Mal lake view sub station & Lake view near High Mast light) (a) INCOMING:- (i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 36 KA, 250 Amps 415 Volt - 1 No (b) OUTGOING (i) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 200 Amps 415 Volt - 1 Nos (ii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 160 Amps 415 Volt - 1 Nos (iii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 100 Amps 415 Volt - 2 Nos (iv) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 63 Amps 415 Volt - 2 Nos (v) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 40 Amps 415 Volt - 2 Nos (vi) Astronomical time switch for 24 Hrs setting-1 Nos. (vii) 2 Pole power contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type-1 Nos. (c) 500 Amps aluminium busbar for phase and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos (e) LED type Indication lamp 415 Volts Set of three - 1 Set (f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) Location - Various places at Wellington station.
MCCB 4 pole, 415V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 4 pole, 415V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 4 pole, 415V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 4 pole, 415V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and replacement of 25 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 35 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 50 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 70 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 95 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Supply and replacement of 120 Sqmm 3.5 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note: Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs complete
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/ loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 Cm thick etc complete as specified and as directed.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point and all as specified and as directed.
Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed. (Note: The punned down thickness shall only be measured)
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm all as specified and directed.
Cutting PCC/ Road 200 mm thick for laying of cable all as specified and directed
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation of steel poles/ struts as specified including necessary for work complete all as specified and directed.
GI Pipe galvanised light grade 50 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/block end including taking down old pipe all as specified and directed.
GI Pipe galvanised light grade 80 mm dia for cable protection in trenches/ at PCC pole for loopin/ loop out of cable and cable entry at Bldg/block end including taking down old pipe all as specified and directed.
GI Pipe galvanised light grade 100 mm dia for cable protection in trenches/ at PCC pole for loopin/loop out of cable and cable entry at Bldg/ block end including taking down old pipe all as specified and directed.
Tacking down old unsv Changeover switch, Supply and fix MCB Type 4 Pole Two way Centre OFF Changeover switch 63 Amps Rating complete all as specified and directed. Make: C&S product code- CSCOS4P63A or Equivalent techno Commercial make in L & L / ABB/ Legrand.
Supply and Fix in repairs Automatic Protector for Neutral Break, Floating Neutral, Low Voltage, High Voltage, Surge Voltage Automatic protection Device for Single Phase 40Amps to 63Amps all as specified and directed. Make: L&T/ C&S/ Havells
Supply and Fix in repairs Automatic Protector for Neutral Break, Floating Neutral, Low Voltage, High Voltage, Surge Voltage Automatic protection Device for 3 Phase 100Amps all as specified and directed. Make: L&T/ C&S/ Havells
Replacement of old unserviceable aluminium thimble (End terminals/ inter connector) of size up to 120Sqmm from cable end/ panel board in repairs complete all as specified and directed. Make: Dowells/ Jainson
Tacking down old unserviceable time light distribution board and Supply and fix time light distrubution baord (Security light timer) time light contactor rating 32 Amps 2 pole MCB SPN 40 Amps for street light control with enclosure complete all as specified and directed. Make - Havells/ Legrand/ ABB
Taking down old unservicable Contactor Supply and fix 2 pole power Contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type Complete all as specified and directed. Make: L&T/Legrand/ CG
Supply and fix in repairs Time light distribution board (Security light timer) time light contactor rating 32 Amps 3 pole MCB TPN 40 Amps Astronomical Timer street light panel for street light control with enclosure complete all as specified and directed. Make - Havells/ Legrand/ ABB
Taking down old earthing material and earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 × 6mm means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including necessary excavation, earth work, PCC pit, RCC cover, funnel, watering pipe etc. all as specified or indicated including testing on completion all as specified and directed.
Schedule of Credit (Minus) Rs. 58045.00 NOTE: Bidder shall insert credit amount of Rs. 58045.00 as rate in Green field under Col-5.
A.GOVINDARAJ (BID ID -3359055)
SREEKRUPA ENTERPRISES (BID ID -3359022)
K.AYYAPPAN (BID ID -3359348)
S.RAMACHANDRAN (BID ID -3359009)
T C KARUNANITHI (BID ID -3359484)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .