Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹44.6 L+₹5.4 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Quoted High rates | |
| 3 | Rejected-Technical NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | - | Rejected-Technical Not enlisted in category | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in category |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 Jul 2021, 5:00 pmClosed
GE NDA KHADAKWASLA
GE NDA KHADAKWASLA
SPECIAL REPAIR TO A SUBSTATION BLDG AND CONNECTED WORKS AT NDA KHADAKWASLA
2021_MES_455749_1
8509/E8
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADAKWASLA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADAKWASLA
₹90,000
Yes
30 Oct 2021
29 Jun 2021
21 Jul 2021
29 Jun 2021
19 Jul 2021
5 Jul 2021
30 Jun 2021 - 30 Jun 2021
Amount
Taking down Chowkhat or frames n.exc 1.50 Sqm each (without taking off shutters from the frame) all as specified and directed.
Taking down chowkat or frames exc 1.50 Sqm but n.exc 4 Sqm each (without taking off shutters from the frames)all as specified and directed.
Rescuring or easing and adjusting without taking down shutters if any description n exc 1 sq. m each including necessary hinges required.
Rescuring or easing and adj usting without taking down shutters if any description exc 1 sq. m and n exc 2sqm each incl necessary hinges required.
S&F steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type, thickness lath 1.0mm all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410 -W (Gde-E- 250) quality-A.
M&L for preparing new steel surfaces over 10cm in width or girth,applying two coats of synthetic enamel paint over a coat of red oxide primer.
S&F IInd class Hardwood solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
S&F 35 mm thick factory made 2nd class Hardwood kiln seasoned and chemically pressure treated plain framed Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), supplied and fitted to chowkat all as specified and directed.
S&F 35 mm thick factory made 2nd class Hardwood glazed and Skelton shutter open rebated and prepared to receive glass, gauzed etc edges of framing plain chamfered fitted with cut and mitred beads for securing with mesh for securing glass size of members of windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) all as specified and directed.
S & F in repair 2nd class hard wood plain fillets. square, rectangular or triangular in section, wrought, secured with screw sectional area n exc 3 sqcm.
M&L for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) in hold fast all as specified and directed.
S&F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 410-O 0r Fe 310-O.
S&F 2nd class hardwood small fitting such as brackets of any type, latch and hinge blocks, shaped door and window stop and the like, including all necessary labours articles n.exc 200 cucm each.
S&F 2nd class hardwood small fitting in repairs such as door & windows stops incl all necessary labours articles n.exc 200cu.cm each incl necessary hinges required.
S&F Butt hinges, 75 mm size heavy weight, cold rolled mild steel, and fixed all as specified and directed.
S&F Butt hinges, 100 mm size heavy weight, cold rolled mild steel, and fixed all as specified and directed.
S&F 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed all as specified and directed.
S&Fin repairs 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F 100 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F in repairs 100 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F 150 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and directed.
S&F in repairs 150 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and directed.
S&F 100 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and directed.
S&F in repairs 100 mm long Mild steel pressed handles, oval type, stove enamelled black all as specified and directed.
S & F 300 mm Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
S & F in repairs 300 mm Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads.
S&F Sheet glass 3 mm thick , ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane.
M&L for preparing new wooden surface of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M & L for one coat of synthetic enamel paint including preparation of old painted surfaces of wood exc 10 cm width or girth etc incl filling of gaps between wooden planks with putty,POP all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M & L for terrazzo tiles 20cm x 20 cm x 20mm thick, with size of chips upto 6 mm; set jointed and pointed in neat cement slurry in floors and cut and polished grey cement and no pigment over 15 mm thick screed bed in cm 1:6.
Terrazzo tiles 20cm x 20 cm x 20mm thick, with size of chips upto 6 mm; set jointed and pointed in neat cement slurry in vertical surfaces as in skirtings, dados and risers of step and cut and polished grey cement and no pigment over 10 mm thick back coat in cm 1:4..
Taking down cement plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and directed.
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces in celing in CM 1:4 finished even and smooth without using extra cement.
M&L rendering 10mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathingwith CM (1:6) finished even and smooth with out using extra cement all as specified and directed.
M&L rendering 15mm thick in two layers, 5mm thick using WPC @3% by weight of cement over 10 mm thick on fair faces of brick or concrete surfaces with CM (1:4) finished even and fair without using extra cement.Note :- WPC will be measured and paid separately.
Supply only Integral water proofing compound.
M&L for preparation of new plastered surfaces of walls to receive distemper and applying two coats of oil bound distemper over 3mm thick wall care putty on wall complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered/unplastered surfaces of wall and applying one coat of cement base paint.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint.
M&L raking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses in lime or cement mortor and pointing in CM 1:3 complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including taking down old water proofing treatment any layers thickness including old brick bat pcc and china mosiac incl removal of debris out of MOD land and stacking at places designated by local municipal authorities.
Roughning surfaces of concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc and applying cement slurry @ 3Kg/ Sqm all as specified and directed.
M&L for screed bed 10 mm thick with CM(1:3) on concrete surfaces )on top of roof slab) mixed with water proofing compound as per manufacturer's instructions surfaces finished even and smooth without using extra cement (WPC shall be measured and paid separately).
M&L for PCC type B-0 , 1:2:4 (12.5mm graded stone aggregate) in any position mixed with water profing compound approved make. Note. Water proofing compound will be paid and mearusred separately.
M&L for WPT laid by torch application method using 3 mm thick APP modified water proofing membrane (with white mineral gravel finish) weighing not less than 3.5 Kg/ Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified & procured from any of the approved manufactures including applying oil based bituminous primer @ 300 gm/ Sqm and treating joints/change in direction with cm 1:3 mixed with SBR Latex @ 200 ml per bag of cement before laying membrane and plaster.
Demolition of reinforced cement concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work) (reinforcement cut as required to facilitate demolition)and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed. Note : (i) The RCC repairs work to be carried out in parts (ii) The additional supports/framework required to support slab at bottom in partly demolition work is deemed to be included in rates quoted.
M&L for RCC 1:2:4 type B1 (using 20mm graded agregates as in chajjas.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L TMT Bars 10mm dia and over cut to length bent to shape required including cranking bending and spirally for hooping for colums hooking ends and binding with ms wire n. less than .9mm dia.
S&F TMT bars 6mm to 8mm dia, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410 -W (Gde- E- 250) quality- A.
S & F Rolled mild steel plates as in guesset plates, base plates etc incl necessary fasterners required fir fixing complete all as specified and as directed.
S&F Mild steel bolts purpose made, with hexangonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 20cm n.exc 25 mm complete all as specified fixed to stone masonry wall.
Cutting grooves in brick/stone wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 after fixing of PGI /CGI sheet all specified and directed.
Dismantling plain or corrugated steel sheeting , any gauge , thickness all as specified.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed.
M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.
M&L for 50mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.
M&L for 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.
M & L for 100 mm thick plain cement concrete type B2 using 40mm graded stone aggregate (1:2:4) as in hard standing /path etc or simillar works all as specified and directed.
Finishing concrete surface by brooming.
M & L for forming 12 mm thick Expansion joints to the full depth of pavement concrete filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade A thickness of slab not exceeding 20cm thick complete all as specified and direccted.
M & L for forming contraction/dummy joints of size 10 mm wide 55 to 65 mm deep filled with sealing compound Grade 'A' including priming the surface all as specified and directed.
M & L for forming construction joints of size 10 mm wide x30 mm deep filled with sealing compound Grade 'A' including priming the surface all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar.
M&L for providing plain cement concrete 1:4:8 type D2 using 40mm grade agg. As in foundation filling and mass concretel as specified and directed.
M&L precast cement concrete 1:3:6 type C-1 ( using 20mm graded aggregate ) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar 1:6 complete in wall all as specified.
M&L cement concrete 1:3:6, type C-1 using 20mm graded stone as in surface channel and drains complete all as specified and as directed.
M&L for forming fair finished drain or channel 60cm inner girth in cement concrete, using extra cement including forms moulds, mitred/stopped ends etc complete all as specified.
M&L providing precast ce- ment concrete type B1 (1:2:4) 20 mm graded stone aggregate as in kerb stones , win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, columns, posts,pier caps, boundary pillars, bed plates, pintle blocks,anchorage blocks, bonders (for stone walling) corbles, brackets etc., (of any section indicate), with plain fair faces is, weatherings, throating etc., and setting in CM (1:4) complete with joints to match all as specified and directed.
Dismantling fencing wire mesh,any type.
Dismantling mild steel work of any description and in any position complete all as directed.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming
S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
Excavation in post holes in hard dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, all as specified and directed.
M & L for plain cement concrete in 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling or mass concrete or simillar work all as specified and directed.
M&L Mild steel flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or riveting etc and similar work conforming to FE-290 Gde E-165.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other, or screwed both ends, each screwed end to be fitted with washers and hexagonal or square nut length of bolt exc 10cm but n.exc 20cm long and dia of neck 11 to 15mm.
Supply only, chain link fencing of MS galvanized fencing, any size or type.
Fixing only chain link fencing including line wires, any mesh , size and type fixed to any type of standards, rails, straining bolts, etc., incliding provision of binding wire complete all as specified and directed Note : Supply only chain link fencing and line wire will be measeured and paid separately.
S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooking ends stiffeners confirming to FE-410-W ( Gde E 250) quality-A or Fe 290 (Gde E-165).
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard /dense soil all as directed.
Returning filling in soil including spreading levelling, watering & well ramming in layers n. exe 25cm (Soft /disintregated rock).
Removing excavated material not exc 50mtr and depositing where directed at a level exc 1.5 Km But not exc 5.0Km above the starting points in any type soil.
S&F UPVC Pipes 100/110mm dia as in weep holes.
Taking down/Disconnecting carefully Incoming and Outgoing LT UG Cables (approx 15-20 No of cables of size upto 400 Sqmm) from Existing LT Panel/DB/ Change Over Switch/ACB/DG Sets etc and connecting these incoming cables to newly installed Bus Bar Panels according to site requiremnt after taking proper power shut down and exercising all safety precautions for human safety including cleaning the duct/trench of size approx 15x1.5x1 Mtr (LxWxD) by opening and removing foreign material/mud from complete trench/cable duct including reconnecting all LT UG Cable connection with existing LT Panel/DB/Change Over etc according to existing system complete all as directed.
Labour for Pruning / Trimming of Tree Branches (Max 5-8 Branches per tree, dia of branch approx 200 mm) interfering or overhanging to the Transformer /Two or Four Pole Structure at Power House / 'A' Sub Station building by taking proper shut down for human safety complete all as directed. Note : Removal of tree branches and dispose away atleast 100 mtrs from substation yard and arrangement of ladder etc is the responsibility of contractor.
Labour for Lifting/shifting/transporting old unserviceable LT ACB Panel (Approx size 2.5x0.85x1.8) mtr from the 'A' Sub Stn Bldg to another panel room (distance not more than 500 mtr one way) by suitable size/capacity of crane including cleaning of complete room complete all as directed.
S & F Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7032 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, openable locking arrangement for front and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber. The panel shall be provided with aluminium bus bars, shall not be less than 700mmX50mmX10mm( L x W x thickness) electrolytic grade of adequate rating including required size of nut bolts for fixing of cables upto 400 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All Cable connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers including suitable size of Lugs, thimbles etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 1.2 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, 04 Nos of entry holes for cables from bottom side upto 400 Sqmm cable size and each bus bar shall be arranged to connect 04 Nos of cable including nut, bolts and washers etc. The overall size of the Busbar panel shall not be less than 800mmx400mm x700mm (LxWxH) including earthwork all as directed and specified by Engr in Chrage. Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved.
S & F of 11 KV HT Bus Bar Panel weather proof outdoor type single door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of Post Office Red Colour shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, openable locking arrangement for front and back side also, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber. The panel shall be provided with Aluminium bus bars Suitable for 200 Amps 11 KV HT, electrolytic grade of adequate rating. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.2 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 (Type C2) at suitable depth as per site requirement . The overall size of the panel shall not less than 1000mmX600mmX1250mm (LxBxH). The panel shall be provided with 2 Nos of Earting Terminals one on each side of the Panel with earth strip, 04 Nos of entry holes for cables from bottom side upto 300 Sqmm cable size and each bus bar shall be arranged to connect 04 Nos of cable including nut, bolts and washers etc. Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved.
Labour for taking down 5 Way RMU (size 2.5x0.85x2.0) Mtr from Angle Iron Support, disconnecting all HT Cables (Approx 05 No of Cables, size upto 120 Sqmm) of any size from RMU as well as transformers including Lifting/shifting/transporting same RMU from Existing Panel Room to Proposed Panel Room (distance not more than 50 mtr one way) with the help of suitable size/capacity of crane or maually and after completion of repair work of Existing Panel room, same RMU again re-installed back in previous Panel Room on the existing Angle Iron Stand and re-connected all HT Power Cables according to the previous system complete all as directed at site.
Labour for taking down LT ACB Panel (Approx size 2.5x0.85x2.0) Mtr from Angle Iron Support, disconnecting all LT Cables of any size (Approx 06 Nos of cable, size upto 400 Sqmm) from LT ACB Panel as well as transformers including Lifting/shifting/transporting same LT ACB Panel from Existing Panel Room to Proposed Panel Room (distance not more than 50 mtr one way) with the help of suitable size/capacity of crane or maually including all new cable termination with suitable size of AL Lugs, Nut, bolts and washers etc complete all as directed at site.
Labour for taking down LT ACB Panel (Approx size 4.0x0.85x2.0) Mtr from Angle Iron Support, disconnecting all LT Cables of any size (Approx 09 No of cables, size upto 400 Sqmm) from LT ACB Panel as well as transformers including Lifting/shifting/transporting same LT ACB Panel from Existing Panel Room to Proposed Panel Room (distance not more than 50 mtr one way) with the help of suitable size/capacity of crane or maually including all new cable termination with suitable size of AL Lugs, Nut, bolts and washers etc complete all as directed at site.
Supply and laying in trenches including testing & commissioning cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminium conductor of cross sectional area 120 Sqmm 3 core (earthed) including termination on both side of HT Bus Bar/Panel/RMU/Transformer etc complete all as directed.
Supply and laying in trenches including testing & commissioning cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminium conductor of cross sectional area 95 Sqmm 3 core (earthed) including termination on both side of HT Bus Bar/Panel/RMU etc complete all as directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm
M& L for Cable End jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm
M & L for Cable End jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.
M & L for Cable End jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm.
Supply & Laying in trenches including testing of LT UG power cables, XLPE Insulated, screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with Multi-Stranded aluminium conductor including termination on both side of LT Panel/Feeder Pillar/Sub Feeder Pillar/Street Light Junction Box etc with suitable size of AL Lugs, Cadmium plated high tensile nuts, bolts and washers etc 3.5 Core 400 Sqmm
Ditto as per item No 109 but 3.5 Core 300 Sqmm
Ditto as per item No 109 but 3.5 Core 240 Sqmm
Ditto as per item No 109 but 3.5 Core 185 Sqmm
Ditto as per item No 109 but 3.5 Core 150 Sqmm
Ditto as per item No 109 but 3.5 Core 120 Sqmm
Ditto as per item No 109 but 3.5 Core 95 Sqmm
Ditto as per item No 109 but 3.5 Core 35 Sqmm
M&L for Straight through LT cable heat shrinkable jointing kit suitable for 1100 Volts LT UG XLPE Power Cable of size 3.5 Core 400 Sqmm
Ditto as per item No 117 but 3.5 Core 300 Sqmm
Ditto as per item No 117 but 3.5 Core 240 Sqmm
Ditto as per item No 117 but 3.5 Core 185 Sqmm
Ditto as per item No 117 but 3.5 Core 150 Sqmm
Ditto as per item No 117 but 3.5 Core 120 Sqmm
Ditto as per item No 117 but 3.5 Core 95 Sqmm
Ditto as per item No 117 but 3.5 Core 35 Sqmm
M & L for Core cutting in any type of wall from 100 to 150 mm dia complete all as speciified and directed at site.
Re-laying/Re-routing of LT UG XLPE Cable, size 35 to 300 Sqmm 3.5 Core in trench or calmping on wall with suitable size of shaddle, Nut, bolts and washers etc complete all as speciified and directed at site. Note : Excavation and earth work will be measured and paid separately under respective item of BOQ.
Labour for Lifting/ shifting/ transporting old unserviceable 4 way RMU (Approx size 2.5x0.85x2.0) Mtr from the 'A' Sub Stn Bldg to another panel room (distance not more than 500 mtr one way) by suitable size/capacity of crane or manually complete all as directed.
Repair /servicing & commissioning of 200 KVA capacity indoor type AMF panel by replacing 3 pole power contactor 315 amp, multifunction meter and HRC fuse DIN type 315 amp rating -03 Nos including grouted in PCC foundtion at suitable height and both cable termination with suitable size of Cable lugs, nut bolts & washers etc including Lifting/shifting/transporting same AMF Panel from Existing Panel Room to Proposed Panel Room (distance not more than 50 mtr one way) with the help of suitable size/capacity of crane or maually and after completion of repair work of Existing Panel room the same AMF Panel again installed back in same Panel Room on the existing Angle Iron Stand and re-connected all LT Power Cables according to the previous system complete all as directed at site complete all as directed.
Repair /servicing & commissioning of 250 KVA capacity indoor type AMF panel by replacing 3 pole power contactor 400 Amp, multifunction meter and HRC fuse DIN type 400 Amp rating -03 Nos including grouted in PCC foundtion at suitable depth and both cable termination with suitable size of cable lugs, nut bolts & washers etc including Lifting/shifting/transporting same AMF Panel from Existing Panel Room to Proposed Panel Room (distance not more than 50 mtr one way) with the help of suitable size/capacity of crane or maually and after completion of repair work of Existing Panel room the same AMF Panel again installed back in same Panel Room on the existing Angle Iron Stand and re-connected all LT Power Cables according to the previous system complete all as directed at site complete all as directed.
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe in soft/disintegrated rock.
M&L for dry river sand for cushioning to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed. Note : For measurement purpose punned thickness shall be considered.
Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the cable, complete all as specified and directed.
Supply & laying un-reinforced precast concrete cable cover, class HV, Type I, flat size 300 mm x 180 mm x 40 mm complete as specified and directed.
M & L for GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 32 x 6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for transformer, LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 including with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed including testing on completion.
M & L for GI tubes, light Grade, galvanised with all fittings, laid in trenches for Cable protection or with pole /Transformer for protection by bending and grouted in cooping including fixing on wall/sufrace with suitable size of GI shaddle, screws, etc of 100 mm dia complete all as specified and directed.
Labour for cleaning the complete sub stn yard by removing tree roots, sepplings, grass etc and thrown out atleast 100 mtr away from the sub stn yard (Max Area of Sub Stn Yard 50 x 30) Mtr complete all as directed.
M&L 20/40mm graded stone aggregate for evenly spreading at substation yard upto the required thickness from natural ground level complete all as directed.
M & L for GI earth strip 32x6 mm size including connect with equipments /machinery beyond 7.5 Mtr by neans of nut, bolts, washers including SMC/FRP Insulators fixed at suitable gaps/intervals etc complete all as directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces all as directed
M&L point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unsheathed cable and including surface, PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box suitable for switches, sockets, fan regulator etcOne light/Fan point controlled by one way switch 6 Amps 240 volts
Ditto as per item No 140 but One 3 pin socket outlet, 5/6 Amps, independent
Ditto as per item No 140 but One 3 pin socket outlet, 5/6 Amps on the same board with other switches
Ditto as per item No 140 but One 3 pin socket outlet , 15/16 amps on independent board with cable 4 Sqmm and4 sqmm as earth wire
S & F switch piano flush type 5 Amps SP one way all as specified.
S&F Socket outlet, 3 pin 5 Amps flush type
M&L Switch socket Combination 16A, 3 pin, flush type
M&L Switch socket combination 2 in 1, 5A flush type
M&L in electronic step type ceiling fan regulator Conform IS 4615-1968 120W, flush type.
S&F ceiling rose surface shall comply with IS :371-1979 Bakelite 60x 25 mm two to three terminals plates and of outside diameter not less than 63.5mm.
S&F LED tube light with diffused optics ultra bright LED tube light 18/20watt with high efficiency,integrated aluminum heat sink suited for installation in existing T8 tube light with G13 lamp holders all as specified.
S&F in replacement 1x18/20W,230V surface and wall mounted batten suitable for installing LED Tube including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified .
Taking down the ceiling fan carefully and cleaning/Servicing the fan if any repairs/replacing of parts required complete including painting the fan with enamel spray paint white coloured and fixing back the fan with fixing accessoires required at site and replacing existing wornout fan hooks.
S&F in replacement LED security light fiitting 30W,IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete fixing with GI bracket made out of 40mm bore GI pipe light grade suitable length bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including surface conduit heavy grade not less than 20mm complete with accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with conduit heavy duty shall be measured as one RM)
S&F in replacement MCB DB 08 way SPN Double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site
S&F MCB SP 6 to 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
Supply and fix in replacement of C Curve MCB DP 6-40 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
GRAND SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .