HLUESS BARC Trombay
Servicing of pumps, blowers, split air conditioner, FCU and associates at PRAFPUL, S-61 and SPF at BARC, Trombay, Mumbai-400085
2022_BARC_675465_1
BARC/HUES/RM-264/38/2021-2022
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
540 days
BARC Trombay
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹52,000
Yes
HLUESS Office PRAFPUL South Site BARC
12 Jul 2022
28 Feb 2022
29 Mar 2022
28 Feb 2022
28 Mar 2022
28 Feb 2022
28 Feb 2022 - 15 Mar 2022
16 Mar 2022
Amount
Servicing of following Pumps (Excluding motors) as per clause No. 1 of the technical specification.
Attending to quarterly (once in three Month) preventive maintenance of the following capacilty pumps.
Condenser & chilled water circulation pump capacity 300 to 400 CMH at 30 & 40 M head, 55 KW motor.
Horizontal split casing domestic water pump, Capacity 40 CMH at 40 M head, 7.5 KW motor.
Horizontal split casing chilled water booster pump, Capacity 39 CMH at 30 M head, 7.5 KW motor.
Overhauling (including providing of consumables) of following pumps.
Condenser & chilled water circulation pump capacity 300 to 400 CMH at 30 & 40 M head, 55 KW motor.
Horizontal split casing domestic water pump, Capacity 40 CMH at 40 M head, 7.5 KW motor.
Horizontal split casing chilled water booster pump, Capacity 39 CMH at 30 M head, 7.5 KW motor.
Servicing of Fans (excluding motors) and attending all complaints/breakdowns of fans as per clause No. 2 of the technical specification.
Capacity 36000 CFM at 100 mm WC static for P-I supply air system. 30 KW motor.
Capacity 42000 CFM at 250 mm WC static for P-I exhaust air system. 75 KW motor.
Capacity 20000 CFM at 80 mm WC static for P-II supply air system 18.5 KW motor.
Capacity 24000 CFM at 250 mm WC static for PII exhaust air system. 55 KW motor.
Capacity 4000 CFM at 300 mm WC static for P-II Fume hood exhaust air system. 11 KW motor.
Capacity 12000 CFM at 50 mm WC static for P-I recirculatory AHU. 5.5 KW motor.
Capacity 8700 CMH at 300 mm WC static for SPF exhaust air system. 5.5 KW motor.
Capacity 2824 CFM at 80 mm WC static for SPF AHU. 2.2 KW motor.
Capacity 8500 CMH at 300 mm WC static for S-62 exhaust air system. 5.5 KW motor.
Capacity 8500 CMH at 300 mm WC static for S-60 exhaust air system. 5.5 KW motor.
Capacity 4414 CFM at 80 mm WC static for S-62 AHU. 2.2 KW motor.
Capacity 4414 CFM at 80 mm WC static for S-60 AHU. 2.2 KW motor.
One time servicing of pot strainers (size approx 400 mm diaX 400 mm height) of water cerculation system at PRAFPUL as per clause No. 3 of technical specification.
Servicing of Split Air Conditioners as per clause No. 4 of technical specification.
Bi-monthly servicing including complaint/break down maintenance of 1.5 TR capacity split air conditioners.
Overhauling (BDS) of split air conditioners of 1.5 TR capacity split air conditioners.
Monthly maintenance & servicing of in-line water purifiers/filters as per the clause No- 5 of the technical specifications.
Supply and one time replacement of all filter elements (pre-filter, fine filter, charcole filter, etc) for UFM technology based in-line water purifier units (Item No. 7) as per the clause No-6 of the technical specifications.
Comprehensive monthly maintenance & servicing of water coolers/water dispenser as per the clause No- 7 of the technical specifications.
Servicing and maintenance of following fan coil units including repair of defective parts as per clause No.8 of technical specification.
Bi-monthly servicing of slim type FCU (with remote control)
One time overhaul servicing of above FCU.
Maintenance and servicing of following sizes fresh air filter which involves unloading, cleaning, drying, loading of filters and carrying out minor repair to its frame as and when required as per clause No. 9 of technical specification.
HDPE filters of Size 500 X 500 X 50 mm (Approx.)
HDPE filters of Size 600 X 600 X 300 mm (Approx.)
HDPE filters of Size 500 X 500 X 150 mm & 600X600X150
Metal filters (SS) of Size 600 X 600 X 100 mm (Approx.)
Servicing & cleaning of FRP cooling tower basin (About 16 M2 area, 400mm depth Approx.) (including repair/ replacement of float valves, nozzels etc. Dpt supply) as per clause No. 10 of technical specification.
External Cleaning of rectangular/circular air supply grilles/VCD with soap solution having surface area up to 0.25 m2 approximate as per clause No. 11 of tech specification.
Office rooms and inactive (general) corridoors
Laboratory and active corridoors
External cleaning of cooling coil banks upto 5M2 at PRAFPUL, SPF, S-61 & S-62 by suitable cleaning agent, using portable water jet cleaning equipment & wire brush as per clause No. 12 of tech specification.
Carrying out miscellaneous jobs (not covered in above items) like shifting of filters and scrap materials etc., using semi-skilled/suitable manpower as and when required as per clause No. 13 of tech spec.
Supply, Replacement, Installation of silent, slim and sleek type fan coil units of 2 TR capacity, of continuous rating along with flow control valve, remote control, temperature control & variable speed etc. and suitable for chilled water application and as per clause No. 14 of technical specifications.
Welding and gas-cutting job for M.S./ S.S. Structure and pipes etc by providing suitable technician for this contract period as per clause no. 15 of technical specification.
Servicing of Daikin make Condensing units (Model no. RXQ14ARY6) connected to DX type Air Handling System as per clause No.16 of technical specification.
Servicing of Process cooling unit as per clause No. 17 of technical specification.
EMPIRE ENGINEERING CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .