Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAdmitted-Finance | ₹27.9 L | L1 | Admitted-Finance |
| 2 | L2₹34.2 LAdmitted-Finance | ₹34.2 L | L2 | Admitted-Finance |
| 3 | L3₹35.0 LAdmitted-Finance | ₹35.0 L | L3 | Admitted-Finance |
| 4 | L4₹38.0 LAdmitted-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | ₹38.0 L | L4 | Admitted-Finance |
| 5 | L5₹38.3 LAdmitted-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹38.3 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | India enterprices L2 | ENJOY L5 | Shri Krishna Trading Corporation L6 | Shree Ayyappa Engineering L7 | K A ELECTRIC CO L4 | M/S VEDHANT ASSOCIATES L3 | NAGESHWAR ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections, dismantling, cleaning geyser tank body properly and removal of scaling etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.
Notes :- (i) Work shall be carried out at the site on routine basis ,
(ii) Spares i.e heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). | 300 | Each | 280 ₹84,000 | 280 ₹84,000 | 280 ₹84,000 | 200 ₹60,000 | 270 ₹81,000 | 200 ₹60,000 | 90 ₹27,000 |
| 2.00 | Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections for repair/replacement of inner tank, assembly, painting etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.
Notes :- (i) Work shall be carried out at the site/workshop as per the requirement/nature of repair.
(ii) Spares i.e inner tank, assembly, heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). | 200 | Each | 280 ₹56,000 | 320 ₹64,000 | 320 ₹64,000 | 150 ₹30,000 | 310 ₹62,000 | 250 ₹50,000 | 80 ₹16,000 |
| 3.00 | S& F in replacement of cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100Volts grade from socket /switch to geyser. | 400 | RM | 145 ₹58,000 | 158 ₹63,200 | 158 ₹63,200 | 168 ₹67,200 | 155 ₹62,000 | 150 ₹60,000 | 90 ₹36,000 |
| 4.00 | M&L for repair of geyser inner tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete | 100 | Each | 190 ₹19,000 | 200 ₹20,000 | 200 ₹20,000 | 400 ₹40,000 | 192 ₹19,200 | 1,500 ₹1.5 L | 120 ₹12,000 |
| 5.00 | S&F D Box with MCB protected Socket with plug 20 A surface/recessed mounting with sheet steel/PVC Enclosure suitable for AC/Geyser & industrial use (without wire) as specification IS 13032 & IS 8623 Cat part No DHDTCSN0251020 of make Havells or its equivelent. complete all as specified and directed by Engineer-in-Charge. | 95 | Each | 540 ₹51,300 | 560 ₹53,200 | 560 ₹53,200 | 900 ₹85,500 | 550 ₹52,250 | 1,500 ₹1.4 L | 620 ₹58,900 |
| 6.00 | S&F in replacement of Geyser water storage tank vertical/horizental type capacity 25 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge | 100 | Each | 1,800 ₹1.8 L | 2,000 ₹2 L | 2,000 ₹2 L | 900 ₹90,000 | 1,950 ₹1.9 L | 2,500 ₹2.5 L | 2,200 ₹2.2 L |
| 7.00 | S&F in replacement of of Geyser water storage tank verticle/horizental type capacity 50 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge | 30 | Each | 2,800 ₹84,000 | 3,000 ₹90,000 | 3,000 ₹90,000 | 1,500 ₹45,000 | 2,916 ₹87,480 | 3,500 ₹1.1 L | 2,800 ₹84,000 |
| 8.00 | S&F in replacement of outer cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge | 120 | Each | 1,800 ₹2.2 L | 1,250 ₹1.5 L | 3,000 ₹3.6 L | 350 ₹42,000 | 2,916 ₹3.5 L | 1,200 ₹1.4 L | 240 ₹28,800 |
| 9.00 | S&F in replacement of outer cover of geyser vertical/horizental type capacity 50 ltr of existing make/model all as specified and directed by Engineer-in-Charge | 30 | Each | 1,180 ₹35,400 | 250 ₹7,500 | 1,250 ₹37,500 | 350 ₹10,500 | 1,230 ₹36,900 | 1,500 ₹45,000 | 290 ₹8,700 |
| 10.00 | S&F in replacement of outer top/bottom cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge | 120 | Each | 300 ₹36,000 | 450 ₹54,000 | 250 ₹30,000 | 100 ₹12,000 | 289 ₹34,680 | 800 ₹96,000 | 180 ₹21,600 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
16 May 2026, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REP /MAINT TO FANS, EXHAUST FANS, GEYSERS AND ACS AT INS SHIVAJI LONAVLA
2026_MES_761522_1
GE/LONAVLA/8428/E8
Open Tender
Civil Works
225 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (I) (NAVY) LONAVLA
₹82,000
Yes
5 Jun 2026
23 Apr 2026
18 May 2026
23 Apr 2026
16 May 2026
9 May 2026
23 Apr 2026 - 7 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections, dismantling, cleaning geyser tank body properly and removal of scaling etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.
Notes :- (i) Work shall be carried out at the site on routine basis ,
(ii) Spares i.e heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). | - | Each | - | - | |
Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections for repair/replacement of inner tank, assembly, painting etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.
Notes :- (i) Work shall be carried out at the site/workshop as per the requirement/nature of repair.
(ii) Spares i.e inner tank, assembly, heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). | - | Each | - | - | |
S& F in replacement of cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100Volts grade from socket /switch to geyser. | - | RM | - | - | |
M&L for repair of geyser inner tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete | - | Each | - | - | |
S&F D Box with MCB protected Socket with plug 20 A surface/recessed mounting with sheet steel/PVC Enclosure suitable for AC/Geyser & industrial use (without wire) as specification IS 13032 & IS 8623 Cat part No DHDTCSN0251020 of make Havells or its equivelent. complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - | |
S&F in replacement of Geyser water storage tank vertical/horizental type capacity 25 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge | - | Each | - | - | |
S&F in replacement of of Geyser water storage tank verticle/horizental type capacity 50 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge | - | Each | - | - | |
S&F in replacement of outer cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge | - | Each | - | - | |
S&F in replacement of outer cover of geyser vertical/horizental type capacity 50 ltr of existing make/model all as specified and directed by Engineer-in-Charge | - | Each | - | - | |
S&F in replacement of outer top/bottom cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf