Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹13.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹13.8 LRejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | ₹13.8 L | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹14.7 LRejected-Finance | ₹14.7 L | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹15.0 LRejected-Finance H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹15.0 L | L4 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | KEWAL SONS L1 | dinesh enterprises L3 | M/S SHRI RAM BUILDERS L2 | M/S PRADEEP KUMAR L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in any type of soil, complete all as specified and directed. | 101 | Cum | 69 ₹6,969 | 50 ₹5,050 | 70 ₹7,070 | 100 ₹10,100 |
| 2.00 | All as per item No 1here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth, complete all as specified and directed. | 0.5 | Cum | 100 ₹50 | 80 ₹40 | 100 ₹50 | 101 ₹50.50 |
| 3.00 | Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each, complete all as specified and directed. | 70 | Cum | 10 ₹700 | 5 ₹350 | 15 ₹1,050 | 65 ₹4,550 |
| 4.00 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. | 31 | Cum | 10 ₹310 | 5 ₹155 | 15 ₹465 | 65 ₹2,015 |
| 5.00 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid. | 20 | Cum | 300 ₹6,000 | 230 ₹4,600 | 200 ₹4,000 | 400 ₹8,000 |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class HV, type 1,flat , size 300mm x 180mm x 40mm. | 1,389 | Each | 18 ₹25,002 | 20 ₹27,780 | 15 ₹20,835 | 18 ₹25,002 |
| 7.00 | Supply and laying in trenches / on roof / on wall / steel water tubing 80mm dia galvanised light grade with all fittings complete all as specified and directed. | 20 | RM | 700 ₹14,000 | 700 ₹14,000 | 500 ₹10,000 | 600 ₹12,000 |
| 8.00 | Supply ,laying , testing & commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor,6.35/11 KV grade (Earthed system cable) as per IS 7098 Part-II, of size 3 Core 95 Sqmm all as directed ,complete all as specified and directed. Note:- (a) Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately. | 285 | RM | 890 ₹2.5 L | 900 ₹2.6 L | 1,025 ₹2.9 L | 900 ₹2.6 L |
| 9.00 | M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination cold shrink type joint 3 Core 50 sqmm to 95 sqmm complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . | 3 | Each | 4,500 ₹13,500 | 4,500 ₹13,500 | 3,985 ₹11,955 | 4,000 ₹12,000 |
| 10.00 | all as per item no 09 here in above but indoor type complete all as specified and directed. | 1 | Each | 4,500 ₹4,500 | 4,200 ₹4,200 | 4,500 ₹4,500 | 4,000 ₹4,000 |
Updated dates
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
8 Jan 2026, 6:00 pmClosed
CWE PATHANKOT
HQ CWE PATHANKOT
PROVN OF EXTERNAL ELECTRIFICATION AND TRANSFORMER FOR MULTIPURPOSE HALL AT MIL STN UNCHIBASSI UNDER GE SOUTH PATHANKOT
2025_MES_743917_1
CWE/P-75/2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE SOUTH PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH PATHANKOT
₹29,000
19 Feb 2026
10 Dec 2025
10 Jan 2026
10 Dec 2025
8 Jan 2026
25 Dec 2025
Amount
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in any type of soil, complete all as specified and directed.
All as per item No 1here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth, complete all as specified and directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each, complete all as specified and directed.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class HV, type 1,flat , size 300mm x 180mm x 40mm.
Supply and laying in trenches / on roof / on wall / steel water tubing 80mm dia galvanised light grade with all fittings complete all as specified and directed.
Supply ,laying , testing & commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor,6.35/11 KV grade (Earthed system cable) as per IS 7098 Part-II, of size 3 Core 95 Sqmm all as directed ,complete all as specified and directed. Note:- (a) Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately.
M&L for cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination cold shrink type joint 3 Core 50 sqmm to 95 sqmm complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed .
all as per item no 09 here in above but indoor type complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M&L for Design, supply, erection, commissioning and testing of indoor type LT feeder pillar box, double door, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Copper bus bar not less 400 Amps for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and mild steel channel (75 MC) base frame at bottom and having welded equal angle of 75mmx75mmx6mm of length 0.9mtr, 04 nos, 30cm of of angle shall be embedded in PCC 1:2:4, 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engr-in-charge at site. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation.
Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-stranded type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. INCOMING : MCCB 4 Pole, 250 Amp 415 Volt, 25 KA (Thermal magnetic release) Isc=100% Icu and adjustable overload setting 80% to 100 % -01 Nos(Incoming) OUTGOINGS : (a) MCCB 4 Pole, 160 Amp, 415 Volt, 25 KA (Thermal magnetic release) Isc=100% Icu and adjustable overload setting 80% to 100 % -04 Nos(outgoing ) (b) MCCB 4 Pole, 100 Amp , 415 Volt, 25 KA (Thermal magnetic release) Isc=100% Icu and adjustable overload setting 80% to 100 % -02 Nos(Outgoing) (c) Bakelite fuse holder with 5 Amps HRC type control fuse - 03 Nos.
(d) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No. (e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (f) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 No (g) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos (h) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (j) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. Note : 1. The feeder pillar Box shall be designed in such a way that adequate workable space is made available inside the compartments and the front area of the panel shall not be less than 1.5 sqm and 500mm depth). 2. The contractor shall submit LT panel/feeder pillar box drawings to the Engr-in-charge for approval before procurement of material.
Supply , install, testing and commissioning of HT 11 KV Switch air break, gang operated, triple pole , 9 insulator, mechanically operated, mounted on insulators and MS channel frame, with operating mechanism made out of 25 mm dia GI medium grade pipe suitable for operation from ground level with locking arrangement complete for current rating 200 Amps , complete all as specified and directed.
S&F HT lightening arrestor metal oxide type (gap less) heavy duty single pole for 11 KV overhead line , suitable for 12 KV rated highest system voltage, long duration distribution discharge class type, IP 55 Degree of protection, 100(kVp) at 65 kA High current impulse withstand voltage and 9 KV Arrestor rating with normal discharge current of 10 KA complete with all fittings conforming to IS: 3070 part-3 effectively connected with earthing system complete all as specified and directed by Engr-in-Charge. Note:- Manufacturer's Test certificate for lighting arrestor shall be produced before claiming for payment, complete all as specified and directed.
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-55 (11.0 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A', complete all as specified and directed.
M&L anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and directed.
S&F expulsion fuse single phase above 50 & up to 100 AMPS capacity, 11000 Volts, complete all as specified and directed.
M&L for alluminium conductor steel reinforced for interconnection the HT line complete all as specified and directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings, complete all as specified and directed.
M&L for fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one, complete all as specified and directed.
M&L for fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wire including dismantling old one, complete all as specified and directed.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old one, complete all as specified and directed.
Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay , complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc , complete all as specified and directed.
Plain cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) for coping of pole, transformer plinth/foundation complete all as specified and directed.
S&F cable route marker of size 100mm x 5mm thick GI plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC 1:2:4 type B 1 as required for HT/LT cable including necessary earth work complete all as specified and directed.
Supply , installation, commissioning and testing of AC 3 phase 50 HZ 100 KVA capacity, step down transformer , Outdoor type 11000/433 volts(at no load), as per IS-2026, LEVEL - 3 copper wound, ONAN, oil cooled, oil immersed with oil tank and filled with ISI marked insulating oil (IS-335) up to the top level in oil tank with oil level indicator, Breather assembly with silica gel, lifting hook, drain valve, air vent valve , wheel with channel and locking arrangement to put on the plinth with external cooling tubes, core type, delta star connected in accordance with vector symbol DYN-11(vector group-4) with neutral brought on (LV) side & having tapppings in 7 steps in equal steps of 2.5%, (Plus/Minus 7.5 % on plus and minus side to vary the secondary voltage primary side by means of hand operated off load tap changing gear, so as to change/correct HV voltage on secondary side including provision of all necessary /standard fittings including all jointing materials, connecting with electrical system, earthing, testing and commissioning all as conforming to Level -3, IS 1180 (Pt-I)/2014 and mainly comprising of the following.
(a) One cable end box on HV side having cable glands suitable for 95 sqmm 3 core XLPE 11 KV HT cable (consisting of 3 Nos porcelain H.T bushings with brass/gun metal bushing rods complete with nuts and washers).(b) One cable box on secondary (LV) side consisting of 4 Nos porclain bushings with GM bushing rods complete with GM nuts, and washers and suitable size extended copper bus bar strip for connecting of 400 sqmm 3.5 core cable with two No cable gland suitable for reception of 1 run of INCOMING LT PVC sheathed armoured cables of size 400 sqmm 3.5 core (c) Oil conservator with filter type, drain valve and oil level gauge. (d) Dehydrating breather assembly with first fill of denydrating agent. (e) Explosive vents. (f) Thermometer pocket on tank cover. (g) One temperatoure indicator 150mm dia with alarm and trip contact, and one winding temperature indicator with alarm and trip contact with marshalling box and connector in and including providing of suitable core control cable, armoured to connect Marshalling box to RMU/VCB complete and testing on completion (h) Rating plate owith terminal markings. (j) Two earthing terminals on tank /tank cover to facilitate fixing of 32x 6m GI earth strip. (k) Oil level guage. (l) Oil drain and filter valves. (m) Oil filter hole with cap /plug wityh connections complete. (n) Lifting lugs. (o) Air relief valve plug.
(p) Four plan solid cast steel detachable rollers. (q) First fill of fresh oil conforming to relvant IS and testing upto 40 KV dielectric strength. (r) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral (s) Buchholz relay with alarm and trip contact and shut off valves and connecting to marshalling box or RMU/VCB for making Buchholz functional complete. (t) Provision of 2 Nos of danger boards 250x200 mm size made out of 1.6 mm thick MS plate , vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (u) Any other fittings/accessories so as to conforming to Level -1, IS 1180 (Pt-I)/2014. (v) PCC plateform as directed by Engr-in-charge for mounting of transformer Make of Transformer- ITE Gurgoan, Siemens, Schneider
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M&L for construction of platform of size 3000 x 2500 x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangement complete all as per Drg No. CEPZ/C-TD/002/13 complete all as specified and directed.
Supply and laying synthetic Insulating Mat of size 2m X 1m and 2.0 mm thick for up to 3.3 KV for electrical purpose as per is 15652-2006 ,(Superseding IS 5424) suitable for electrical shock safety made from synthetic insulating material, free from any insertions leading to detoriation of insulating properties. Note : The upper surface should have small aberration (Rough Surface) with out edges to avoid slippery effects.The mat should be fire retardant & self extiguishing complete all as specified and directed.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
M/S SHRI RAM BUILDERS (BID ID -3513480)
dinesh enterprises (BID ID -3513438)
M/S PRADEEP KUMAR (BID ID -3519585)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tender75.pdf
Tender Documents • 1.18 MB
BOQ_832983.xls
BOQ • 1.11 MB
Download all tender documents and submit your bid