Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BALVINDER SINGH S O LATE SH LAL CHAND SHERPUR SHERPUR TEHSIL DALHOUSIE CHAMBA HIMACHAL PRADESH 176306 | CHAMBA | HIMACHAL PRADESH | 176306 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.3 L
Closing Date
27 Dec 2021, 4:30 pmClosed
xen rew kathua
xen rew kathua
Constt. of toilet complex near Dhola Adda
2021_RDPR_154388_11
e-NIT No. 231 REW/K of 2021 Dated 21/12/2021
Open Tender
Civil Works
Item Rate
30 days
kathua
sbd
2 documents required · 2 mandatory
₹500
Yes
xen rew kathua
Exempted
7 Jan 2022
21 Dec 2021
28 Dec 2021
22 Dec 2021
27 Dec 2021
22 Dec 2021
Amount
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directedAll kinds of soil :1 meter from cutting edge including aLL carriages and lifts
Providing and laying in position cement concrete of specified grade inculding curing but excluding the cost of centring and shuttering- All work upto plinth level in 1:5:10(1 cement:5 coarse sand:10 garded stone )40 mm nominal size including all lift and carriages
Providing and laying in position cement concrete of specified grade inculding curing but excluding the cost of centring and shuttering- All work upto plinth level in 1:3:6(1 cement:3 coarse sand:6 garded stone )40 mm nominal size including all carriages and carriages
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete
Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square meter on damp proof courses after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) including carriage
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primerUsing flats 30x6mm for diagonal braces and central cross piece
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Suspended floors, roofs, landings, balconies and access platforms.
Edges of slan under 20 cm wide
6mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
15mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 11.50.1 In colour such as White, Ivory, Grey, Fume Red Brown
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Colour washing such as green blue or buff to give an even shade 13.48.1 New work (two or more coats) with a basecoat of white washing with lime.
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:15 mm dia. nominal bore
Providing and fixing 15 mm dia bore bib cock of approved quality
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing wash basin with C .I Brackets 15 mm C P Brass pillar top 32 mm brass waste of standard pattern including painting and filling and bracket cutting and making good the wall wherever required white viterous china wash basin size 630 x 450 mm with a pair of 15 mm brass pilar tops
Providing and fixing PVS waste pipe for sink or wash basin including PVC waste fitting complete semi rigig 32 mm dia
Providing and fixing 100 mm sand cast iron grating for gully trap
Providing and fixing 600 x 450 mm edge mirror of superior glass of approved quality complete with 6 mm thick board ground fixed to wooden with cp brass screws washers complete etc
Providing and fixing 600 x 120x5 mm glass shelf with edges round off supported to anodized alminium angle frame with cp brass brackets and guard rail complete fixed with 40 mm long screws plugs etc complete
Providing and fixing flow trap size 100 x 75 mm
Providing and fixing waste and vent pipes of approved quality 75 mm diameter
Providing and fixing collars of approved quality 75 mm diameter of sound cast iron
Providing and fixing lead covered joints to centifugally cast iron pipes and filling of diameter of approved quality 75 mm diameter
Providing and fixing PTMT towel rail complete with fixed brackets to wooden with cp brass screws with concealed filling arrangement of approved quality and colour 10 mm long towel rail with total length of 495 m 78 mm thick and height of 88 m
Providing and fixing water closet squatting pan/ indian type W C pan with 10 mm scip or strap 10 litre low level white pvc flushing cister including flush pipe with manually controlled device with all fitting complete
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
Add cost of sign board
M/S BINESH SINGH
JOGINDER KUMAR
BALVINDER SINGH GOVT CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .