Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | ₹34.7 L Quoted ₹34.9 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹42.7 L+₹7.8 L (22.3%)Rejected-Finance | ₹42.7 L+₹7.8 L (22.3%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹45.4 L+₹10.5 L (30.1%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | ₹45.4 L+₹10.5 L (30.1%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹45.5 L+₹10.6 L (30.4%)Rejected-Finance | ₹45.5 L+₹10.6 L (30.4%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹46.5 L+₹11.6 L (33.3%)Rejected-Finance | ₹46.5 L+₹11.6 L (33.3%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Jun 2023, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8520/E8
2023_MES_595608_1
8520/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VASCO
Class D Category b i
7 documents required · 7 mandatory
₹500
GE NW VASCO
₹90,000
Yes
7 Aug 2023
15 May 2023
14 Jun 2023
15 May 2023
12 Jun 2023
30 May 2023
16 May 2023 - 29 May 2023
Amount
S & F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and as directed.
S & F in repairs 1x60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights complete all as specified and as directed.
M & L for in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed.
Supply and fix in repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole / high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection complete all as specified and as directed.
Supply and fix in repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on PCC pole/high mast pole/wall by providing MS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection complete all as specified and as directed.
S & F in repairs wind LED well glass luminaires 1x30 watts Energy saving, environment friendly & robust open type vertical LED luminaire with high power LED as light source complete all as specified and as directed.
S & F in repairs LED High bay luminaires 1x195 / 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source complete all as specified and as directed.
S & F in repairs LED High bay luminaires 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source complete all as specified and as directed.
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core type complete including conduits/casing caping etc, removing the materials/ debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etccomplete all as specified and as directed.
All as per item No 10.00 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
All as per item No 10.00 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor. (Note :- For Srl Item No. 10.00 to 12.00 two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit)
All as per item No 10.00 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor.
All as per item No 10.00 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor. (Note :- For Srl Item No. 13.00 to 14.00 four runs of cable, two run of earth continuity conductor and one run of PVC casing caping/conduit of suitable size shall be measured as one unit)
S & F in repairs Switch Flame proof WP Rotary type with termination box in LM6, 15A single pole 250V complete all as specified and as directed.
S & F in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and as directed.
Supply and fixing LED light fitting 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing in repairs flame proof exhaust fan motor with body of size 300 mm sweep complete all as specified and as directed.
Supply and fixing in repairs flame proof exhaust fan sweep of size 300 mm sweep complete all as specified and as directed. Note:- Fan Blade make and size should be supply with the mach of under relivent item of Sch A serial No 22 as above.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed.
All as per item No 23 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar triple pole.
S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
All as per item No. 23.00 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
All as per item No. 23.00 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
S&F in repairs MCCB DB TPN, 8 way, (MCCB + 24 way O/G) double door, vertical type provision one MCCB of 100 amps breaking capacity 18 KA, 4 pole without MCB complete all as specified and as directed.
S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and as directed.
S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 125 to 160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed.
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed.
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed.
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and as directed.
Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA, 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed.
Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed.
Supply and Fixing Energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lights complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and necessary fixing arrangement at any height and removing old unserviceable complete all as specified and as directed.
Supply & fix recess mounting high lumen LED flat panel 1'x1' 18 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
Supply & fix in repairs recess mounting high lumen LED flat panel 4'x1' 36 Watt, white powder coated CRCA housing with high power LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
S&F in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic driver complete all as specified and as directed.
S & F in repairs Fluorescent tube light fitting. 1x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc complete all as specified and as directed.
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials complete all as specified and directed by Engr-in-charge. .
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
S & F copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed.
S & F in repairs Copper strip 32 x 6 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc incl taking out old one complete all as specified and as directed.
Material and lobour for Servicing of earth pit structure by disconnecting earth strip by opening nuts and bolts 4 pole structures LT/HT including checking all joints, jumpers etc for any loose connection, replacement of burnt jumper with new one, replacement of rusted nut bolts and apply petroleum jelly for all moving contacts complete all as specified and as directed. Note:- All the spares required for the work is included in the quoted rate.
M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub-station yard along with fencing, around the pole, under the HT/LT transmission lines, yards or any description by manually / mechanically and keep the sub-station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean throughout the period of contract and each cleaning will be measured and paid separately.
M & L for Cutting and trimming of tree branches 3 mtr all around of any size obstructing lumination of street light and touching LT/HT Over head line incl removing trimmed tree branches all as directed.
Supply and wrapping of LT insulation tape 12 mm width in 5 mtr roll complete all as specified and as directed.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed.
S & F Perforated cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width / sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/ floor/ through wall crossing and making good the surface complete all as specified and as directed.
S&F in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and as directed. Note :- Wright matters will be provided by department as per requirement.
M & L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and as directed.
S & F in repairs capacitor of 2.5/3.15 mfd capacity for ceiling fan of any sweep complete all as specified and as directed.
S&F in repair Analog time switch fixed in timer panel including connection with screw. nuts and bolts etc. complete all as specified and as directed.
Taking down Aluminum strip of size 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and refixing in the same location with new nuts and bolts, screws of suitable size and length and connected to air termination rod on op of the hangar complete all as specified and as directed.
sapna enterprises
Sagar Constructions
S and G Constructions
Susheel Enterprises
OM SAI ELECTRICALS
D.K. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .