Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ACHNAMBAL ZAFFRON COLONY PANTHACHOWK SRINAGAR J K INDIA 191101 | SRINAGAR | JAMMU AND KASHMIR | 191101 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
27 Apr 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex Engineer std pulwama
Office of Ex Engineer STD Pulwama
Stage Contract for Maintenance of 33 KV Lines Falling under the Jurisdiction of Sub Transmission Division Pulwama for the Year 2022-23.
2022_PDD_166526_1
NIT 03 of 2022-23 std pul
Open Tender
Electrical Works
Item Rate
15 days
STD Pulwama
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Ex Engineer STD Pulwama
₹20,000
2 May 2022
12 Apr 2022
28 Apr 2022
12 Apr 2022
27 Apr 2022
12 Apr 2022
90 days
Amount
Supply, Erection, testing and commissioning of ST Pole with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Erection, testing and commissioning of ST Pole with base plate and top cap including excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard (ST pole to be supplied by deparment)
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Dismantling of ST Pole complete with allied accessories and returning and stacking of same to divisional stores.
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Dismantling of wooden poles of different sizes complete with allied accessories and returning and stacking of same to divisional stores.
Straightening of existing tilted poles
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
DW Wooden Pole
Providing/ Painting of S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Providing and laying of Cement Concrete (PCC) using 20/40mm crush stone aggregate including shuttering ,form work etc in the following ratios
Ratio 01:04:08
Ratio 01:1-1/2:03
Ratio 01:02:04
Providing and laying of Cement Concrete (RCC) using 20/40mm crush stone aggregate including shuttering, form work etc in the following ratios
Ratio 01:1-1/2:03
Ratio 01:02:04
Providing and fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard
Fixing of Galvanised spiral Earthing (in a separate pit) of 8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard
Providing and Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip
Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip
Providing and fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete)
Fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete)
Dismanteling of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete)
Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for
0.2 ACSR Conductor
0.15 ACSR Conductor
0.1 ACSR Conductor
Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for
0.2 ACSR Conductor
0.15 ACSR Conductor
0.1 ACSR Conductor
Laying,stringing ,tensioning and binding of ACSR Conductor as per REC Construction standard (material to be provided by the department)
0.2 ACSR Conductor
0.15 ACSR Conductor
0.1 ACSR Conductor
Supply, Laying,stringing ,tensioning and binding of ACSR Conductor as per REC Construction standard
0.2 ACSR Conductor
0.15 ACSR Conductor
0.1 ACSR Conductor
Re-stringing of loose conductor including tensioning, binding etc
0.2 ACSR Conductor
0.15 ACSR Conductor
0.1 ACSR Conductor
Loading of Steel Tubular Poles including manual carriage from stacking site upto loading site upto a lead of 25mtr
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Unloading of Steel Tubular Pole including manual carriage (manual) upto dumping site and then proper stacking upto a lead of 25mtr
13 mtr Long ST Pole (ST-410SP-69)
11 mtr Long ST pole (ST-410-SP56)
9mtr Long ST PoleST-410 SP-33)
Manual Carriage of ST Poles
Upto first 100mtr lead
For every additional 50mtr or part there off
Loading of Steel and sundry items like CGI sheet, nuts and bolts, Angle Iron, hardware fittings , cross arms etc including manual carriage, proper stacking and sorting etc upto loading site upto 50mtr
Unloading of Steel and sundry items like CGI sheet, nuts and bolts, Angle Iron, hardware fittings , cross arms etc including manual carriage, proper stacking and sorting etc upto loading site upto 50mtr
Manual Carriage of Sundry Items
Upto first 100mtr lead
For every additional 50mtr or part there off
Loading of Conductor Reels ( 0.1ACSR/ 0.2 ACSR/ 0.15 ACSR ) including manual carriage from dumping site and then proper stacking
Unloading of of Conductor Reels ( 0.1ACSR/ 0.2 ACSR/ 0.15 ACSR ) including manual carriage stacking site upto loading
Supply, installation,testing and commissioning of 33KV Polymer Toughened Glass Disc Insulators with fittings Shed diameter 90 mm, Min. Cree page distance 840mm, 25mm Height confirming to Standard: IEC, ANSI, BS Certificate: ISO9001 (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.1/0.15ACSR Conductor (insulators of spark or rashtriya or equivalent make)
Installation,testing and commissioning of 33KV Polymer Toughened Glass Disc Insulators with fittings Shed diameter 90 mm, Min. Cree page distance 840mm, 25mm Height confirming to Standard: IEC, ANSI, BS Certificate: ISO9001 (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.1/0.15ACSR Conductor (insulators of spark or rashtriya or equivalent make)
Supply, installation,testing and commissioning of 33KV Polymer Toughened Glass Disc Insulators with fittings confirming to Standard: IEC, ANSI, BS Certificate: ISO9001 (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.2ACSR Conductor (insulators of spark or rashtriya or equivalent make)
Installation,testing and commissioning of 33KV Polymer Toughened Glass Disc Insulators with fittings confirming to Standard: IEC, ANSI, BS Certificate: ISO9001 (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.2ACSR Conductor (insulators of spark or rashtriya or equivalent make)
Supply,installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.2(Panther) ACSR having 40mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
Installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.2(Panther) ACSR having 40mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
Supply,installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.15 ACSR having 40mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
Installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.15 ACSR having 40mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
Supply,installation,Testing and commissioning of 11KV Disc insulators (45KN) with fitting confirming IS:731 (1971) 3188:1980/ IS:2486 Part -II and IEC-61109-2008 with latest amendments thereof (Porcelaine Type)
Installation,Testing and commissioning of 11KV Disc insulators (45KN) with fitting confirming IS:731 (1971) 3188:1980/ IS:2486 Part -II and IEC-61109-2008 with latest amendments thereof (Porcelaine Type)
Providing and fixing of 11KV pin Insulators (5KN)with GI pins conforming to IS : 731 (1971) standards with latest amendents thereof
Fixing of 11KV pin Insulators (5KN)with GI pins conforming to IS : 731 (1971) standards with latest amendents thereof
Providing and fixing of tension fitting heavy duty type suitable for
0.1ACSR conductor
0.15ACSR Conductor
0.2 ACSR Conductor
Fixing of tension fitting heavy duty type suitable for
0.1ACSR conductor
0.15 ACSR Conductor
0.2 ACSR Conductor
Providing and fixing of danger plates (6"X8"X4mm thick) with clamps
Providing and fixing of anti climbing devices using GI Barbed wire at least 2.0kg per pole fixed with clamps on both ends as per REC Standards
Providing and fixing of fabricated GI Channel / Angle of sorts as per site requirement and REC Standards
Fixing of fabricated GI Channel / Angle of sorts as per site requirement and REC Standards
Providing and Fixing of jumper sets (3 pieces) for 33KV line
Fixing of jumper sets (3 pieces) for 33KV line
Extensive Branch cutting of trees coming in the coridor of 33KV line including cutting of trees beneath the 33KV line (complete job)
Supply,erection,testing and commissioning of 33KV, Single core Aluminium, round wire Armoured XLPE Cable , FRLS One spare cable
Erection,testing and commissioning of 33KV, Single core Aluminium, round wire armoured XLPE Cable , FRLS One spare cable
Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size
Fixing of Cable Termination Kits (indoor/outdoor) for 33KV Grade single core cable of size
Providng and fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts
Fixing of guard netting of existing 33KV line using 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts
Providing and fixing of fabricated MS Angle Iron /Channel Iron of different sorts and sizes as per site requirement
Providing and fixing of Aluminium Jointing Sleeves
Felling trees of the grith (measured at height of 1mtr above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unservicable material.
Beyond 30cm girth upto and including 60cm girth
Beyond 60cm girth upto and including 120cm girth
Beyond 120cm girth upto and including 240cm girth
Above 240cm grith
Fixing of fabricated MS Angle Iron /Channel Iron of different sorts and sizes as per site requirement (Material to be supplied by Deptt.)
Providing and fixing of G.I Nuts and Bolts of Sizes as per site requirement and REC standards.
Providing and fixing of Hollow Copper Tube with external dia 38mm and thickness of 3mm as per site requirement and REC standards.
Supply,installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.1 ACSR having 32mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
Installation,Testing and commissioning of 33 KV 10 KN Polymeric Insulators with pin (composite pin type insulator) with Silicon Rubber for sheds/housing, Glass-fiber reinforced epoxy resin rod (ECR type) for core, Hop dip galvanized cast steel for metal fittings, Confirming to ISO9001: 2008 standards (suitable for temp from -10 to 40 degree Centigrade) suitable for 0.1 ACSR having 32mm dia fiber rod (insulators of spark or rashtriya or Equivalent make)
M/S ARB CONSTRUCTIONS
M/s SHEERAZ ENGINEERING WORKS
M/S AKASH ELECTRICALS AND MECH
Ess Bee Electricals
M/S KHAN ELECTRICAL ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .