Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being lowest one | |
| 2 | Rejected-Technical 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | - | Rejected-Technical Due to ban HQ CE(Navy) Visakhapatnam due to slow progress |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
26 Sept 2020, 6:55 pmClosed
GARRISON ENGINEER CHILKA
GARRISON ENGINEER CHILKA INS CHILKA POST KHORDHA-DIST ODISHA-752037
REPAIR AND MAINTENANCE OF SPLIT AC WINDOW AC TOWER AC WATER COOLER REFRIGERATORS OF VARIOUS CAPACITIES AND OTHER CONNECTED WORKS AT INS CHILKA UNDER GE CHILKA
2020_MES_357180_1
GE/CHL/8654 of 2020-21
Open Tender
Civil Works
Item Rate
270 days
GARRISON ENGINEER CHILKA
MES enlisted contractor of Class E category c i
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CHILKA
₹23,000
Yes
24 Nov 2020
30 Jun 2020
3 Oct 2020
30 Jun 2020
26 Sept 2020
15 Jul 2020
30 Jun 2020 - 7 Jul 2020
Amount
S&F of 1.5 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split/ window AC including testing complete all as specified and as directed.
S&F of 2 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split/ window AC including testing complete all as specified and as directed.
S&F of 3 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split AC including testing complete all as specified and as directed.
S&F of 4 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split AC including testing complete all as specified and as directed.
S&F of 1 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split/ window AC including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressors hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 120 to 180 Litre refrigerator including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 240 to 270 Litre refrigerator including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 60 to 120 Litre water cooler including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 150 Litre water cooler including testing complete all as specified and as directed.
S&F of 1/5HP, 825-1400 RPM condenser fan motor or Blower Motor pre wired, single phase, AC supply, 230 volts, 50 Hz, corrosion resistant with built- in thermal protection (as per sample) complete all as specified and as directed
S&F in repair of condensor Fan blade assembly made up of aluminium or hard PVC of suitable size as existing at site complete as specified and as directed.
S&F in repair of 10 mfd running capacitor for condensor fan of suitable size as existing at site complete as specified and as directed.
S&F in repair of 4 mfd running capacitor for condensor fan of suitable size as existing at site complete as specified and directed.
S&F in repair of 36 mfd running capacitor complete as specified and as directed.
S&F in repair 45+4 mfd running capacitor complete as specified and as directed.
S&F in repair 50/55+4 mfd running capacitor complete as specified and as directed.
S&F 80-100 mfd starting capacitors including taking out old unserviceable capacitor complete all as specified and directed.
S&F 100-120 mfd starting capacitors including taking out old unserviceable capacitor complete all as specified and directed.
Supply and charging of refrigerant R-22 industrial grade in AC, Refrigerator, Water coolers as required complete all as specified and as directed
Supply and charging of refrigerant R-134A industrial grade in AC, Refrigerator, Water coolers as required complete all as specified and as directed.
S&F in repair thermostat for AC / Refrigerator / Water Coolers electronic type with temperature range of the equipment specification with auto cut-off and auto reset feature complete all as specified and as directed.
S&F in repair timer switch with auto reset feature for Air conditioners and refrigerators complete all as specified and as directed
S&F in repair Bimetalic fuse complete all as specified and as directed
S&F in repair of OLP Kit 0072/73 suitable for water cooler/refrigirator of various capacities complete all as specified and as directed
S&F in repair Flare valves of size 1/4 inch as existing at site complete all as specified and as directed
S&F in repair Flare valves of size 5/8 inch as existing at site complete all as specified and as directed
S&F Reversing valves of any size as existing at site complete all as specified and as directed
Supply and replacement of starting relay for water cooler/Refrigirator/AC as existing at site of required capacity complete all as specified and as directed.
Supply and replacement of screw/ pin type fridge bulb 240 volts 10 watt for any type of refrigerator all as specified.
Supply and replacement of knob for window/ split type AC as per existing at site of various makes complete all as specified and as directed.
Supply and replacement of swing motor 240 volts, 50 HZ, 3-8 watts for split/window type ACs of various capacities complete all as specified and as directed.
Supply and replacement of circuit board of split/window AC of capacity 1.5/2/3TR complete all as specified and as directed .
Supply and replacement of cordless remote controller Kit including all accessories for split/ window type AC of 1.5/ 2 / 3 ton complete as specified and as directed.
Supply & replacement of Bimetal over load relay (relay range suitable for MNX18 contactor) including disconnecting & reconnecting inter connections complete all as specified and as directed
Supply and replacement of magnetic EPDM rubber gasket for refrigerator doors of industrial grade ISI marked complete all as specified and as directed.
S&F in replacement of Contactor 2/3 pole 20 to 30 Amps 240 Volt/415 Volt AC supply as existing site l complete all as specified and as directed.
S&F in repair Vertical / Horizontal louvers step motor as existing at site complete all as specified and as directed.
S&F in repair bush / bearing of required size as existing at site complete all as specified and as directed
S&F PVC drain pipe 32/40 mm dia ISI marked complete all as specified and as directed.
S&F PVC drain pipe 15mm dia ISI marked complete all as specified and as directed.
Supply and replacement of drain tray for refrigerator of required size and capacity as existing at site complete all as specified and as directed.
S&F 1/4 inches internal dia copper tube of thickness 1.20 - 1.50 mm , industrial grade ISI marked for refrigerator/watercoolers/ACs complete all as specified and as directed .
S&F 5/8 inches internal dia copper tube of thickness 1.20 - 1.50 mm , industrial grade ISI marked for refrigerator/watercoolers/ACs complete all as specified and as directed .
M&L for gas welding of copper tubes with copper or silver or any other metal as filler material as per site requirementafter required cutting and preperation before welding complete all as specified and as directed.
S&F in replacement of wall mounted 4 KVA single phase voltage stablizer low voltage corrector with input voltage of 160 to 260 volts and out put voltage 240 + 1% complete all as specified and as directed. Make :- V-Guard/Shakti/Zenith
S&F in replacement of wall mounted 5 KVA single phase voltage stabilizer low voltage corrector with input voltage of 160 to 260 volts and out put voltage 240 + 1% complete all as specified and as directed. Make :- V-Guard/Shakti/Zenith
S&F in replacement of floor mounted three phase 415 Volt voltage stabilizer of 6.0 KVA low voltage corrector with input voltage of 380 to 415 volts and out put voltage 415 + 1% of complete all as specified. Make :- V-Guard/Shakti/Zenith
S&F copper condensor coil unit complete as existing at site for ACs / Water Coolers / Refrigerators of any capacity complete all as specified and as directed.
S&F electrical box assembly complete unit for Our door unit / Indoor unit for AC of 1 Ton to 3 Ton Split/ Window AC complete all as specified and as directed .
S&F Terminal blocks 3/4/6 pole and 20 to 30 Amps for outdoor / indoor Unit for AC as existing at the site complete all as specified and as directed.
S&F Out door coil sensor unit for AC/Water Cooler/ Deep Fridgers as existing at the site complete all as specified and as directed.
Supply and replacement of 4 Sqmm three core multistranded copper conductor flexible cable PVC insulated, PVC sheathed 1100 volts grade complete all as specified and as directed. Make :- Polycab/Havells/Plaza
S&F in replacement of MCB SP 6 to 32 Amps 230volts, AC complete all as specified and as directed. Make:- C&S/ Standard/L&T
M&L for taking out Indoor/ Out-door units of AC / Water Coolers/ Deep freezer / Tower AC including shifting and re-installation at any other location as decided by Engineer-in-charge complete all as specified and as directed.
M&L for removing of water cooler of various capacity from the existing position, servicing with HCL acid and water solution and refixing the same in its original position with insulating material complete all as specified and as directed.
M&L for servicing of Air conditioning units of any size in existing position, cleaning it from inside completely, checking and fixing any minor damaged article, electrical wiring etc including testing complete as specified and directed
Supply in replacement of indoor unit of 1.5/2 ton of Split AC complete with fan motor, remote as existing on ground including testing complete all as specified and as directed.
Supply and replacement of front cover of window AC as existing on ground complete as specified and directed
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole,20 amp, 240volt MCB complete all as specified and as directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .