The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Construction of Major Renovation works at DHEPARGAON M.E.S. (18240123103), District Tamulpur under Dharti Aaba Janjatiya Gram Utkarsh Abhiyan (DAJGUA) Tribal Affairs (Plain) for the Financial Year 2026-27.
2026_BTC_54816_2
ACE-83/NIT/DAJGUA/BTC/26-27/27
Open Tender
Civil Works - Building
Item Rate
365 days
Tamulpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
₹1.5 L
Yes
5 Nov 2026
5 Nov 2026
1 Dec 2026
5 Nov 2026
30 Nov 2026
5 Nov 2026
5 Nov 2026 - 30 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of Existing School Bld.1
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
15.28.1G.S. Sheet | 416.73 | Sqm | - | - |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:
15.12.1 Of area 3 sq. metres and below | 20 | Nos | - | - |
| 3 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:
15.14.1 Of sectional area 40 square centimetres and above | 3.45 | Cum | - | - |
| 4 | Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).
12.64.1 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092
mm, cover width 1000mm. | 416.73 | Sqm | - | - |
| 5 | Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of
the sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal
and SS plain washer complete :
12.66.1 Precoated/mill finish aluminium Ridges plain (500- 600mm) | 44.75 | Rm | - | - |
| 6 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.3 Kiln seasoned and chemically treated hollock wood | 3.45 | Cum | - | - |
| 7 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.1 Second class teak wood | 0.68 | Cum | - | - |
| 8 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:Butt hinges and necessary screws shall be paid separately)
9.5.1 Second class teak wood
9.5.1.1 35 mm thick shutters | 24.2 | Sqm | - | - |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand) | 5.9 | Sqm | - | - |
| 10 | 12 mm cement plaster:
13.1.2 1:6 (1 cement : 6 fine sand) | 89.45 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.32 MB
Tendernotice_2.pdf
PDF • 4.40 MB
Tendernotice_3.pdf
PDF • 0.52 MB
BOQ_85849.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .