Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC AT 381 341 SARITA APARTMENT P O KHARAGPUR KHARIDA MAIN ROAD MIDNAPORE WEST WEST BENGAL 721301 | MEDINIPUR WEST | WEST BENGAL | 721301 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹28.1 L+₹3.4 L (13.6%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L2 | Rejected-Finance Higher Bid Value | |
| 3 | Rejected-Technical KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | - | Rejected-Technical Not enlisted in appropriate category | |
| 4 | Rejected-Technical VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | - | Rejected-Technical Not enlisted in appropriate category | |
| 5 | Rejected-Technical 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
17 May 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIKUNDA AIR FIELD POST , DIST WEST MEDINIPORE,721303
PROVN OF MISC E/M AND B/R WORK SERVICES FOR NEW TEST RIG SET UP
2021_MES_432998_2
8374/KKD/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AT AF STN KALAIKUNDA
Class D Category b(I) c(I)
2 documents required · 2 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹57,000
Yes
4 Jun 2021
1 May 2021
19 May 2021
1 May 2021
17 May 2021
4 May 2021
1 May 2021 - 3 May 2021
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out for laying of cable, pipes, poles etc complete all as specified and as directed by Engr-in-charge.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and as directed by Engr-in-charge.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M & L sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and as directed by Engr-in-charge. Note:-Punned thickness to be measured for payment.
Material and labour for fly ash brick laid flat in trenches over sand cushioning for cable protection complete all as specified and as directed by Engr-in-charge.
M&L for laying 100 mm bore GI pipe, light grade, ISI marked with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for laying 80 mm bore GI pipe, light grade, ISI marked with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for laying 50 mm bore GI pipe, light grade, ISI marked with all fittings, in crossing road/path and in pole/wall up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge. Note for item No. 06 to 08 :- Boring under road/path will be measured and paid under respective item
M&L for boring of road/ PCC path/ PCC hard standing/ drain for laying of any grade GI pipe up to 100 mm size in underground for laying of cable without distrubing the existing surface complete all as specified and as directed by Engineer-in-Charge.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core in underground in trench / walls etc as per site requirement including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends complete all as specified and as directed by Engineer-in-Charge.
Supply, Laying, commissioning and testing of LT power cable, XLPE insulated, screened, PVC bedded, inner sheathed, armoured, galvanized steel strip armoured, electric power cable (heavy duty), 1100 volts grade with stranded copper conductor of size 50 sqmm x 3.5 core in underground in trench / walls etc as per site requirement including connecting the cables at both ends by providing suitable size copper lugs at the termination ends complete all as specified and as directed by Engineer-in-Charge.
Supply, Laying, commissioning and testing of LT power cable, XLPE insulated, screened, PVC bedded, inner sheathed, armoured, galvanized steel strip armoured, electric power cable (heavy duty), 1100 volts grade with stranded copper conductor of size 150 sqmm x 3.5 core in underground in trench / walls etc as per site requirement including connecting the cables at both ends by providing suitable size copper lugs at the termination ends complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet metal one way enclouser for MCCB , suitable for accomodating 4 Pole MCCB up to rating of 250 Amp, in CRCA sheet, as per IEC 61439-3 IK 08, suitable for flush / surface mounting, complete all as specified and as directed by Engr-In- Charge, Model Ekinox 3 , Cat Part No. 507802 (DPX 3 250 MCCB enclosure) complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 250 Amp, 4 Pole , 36 kA, 415 V, AC, 50 Hz, Thermal adjustable type, having adjustable overload and short circuit protection, Ics = 100%Icu including, spreaders terminals, phase barriers, making all electrical connection by providing copper lugs etc Model : DPX 3 250 MCCB, Cat Part No. 420248 (DPX 3 250 type MCCB ) complete all as specified and as directed by Engineer-in-Charge.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester powder coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 500 Amps ( Size of copper strip should not be less than 50 x 6 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following.
ITEM 15 CONTD... : (A) Incoming (i) MCCB 250 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 200-250 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with rotatary handle . Make of MCCB : L&T, Cat Part No. CM92109OOP1OG or equivalent in Legrand / Seimens/ Schinder. (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Neon type for three phase. (vi) Slector switch - 2 Nos
ITEM 15 CONTD...(B ) Outgoing : i) MCCB 200 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 160-200 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 01 Nos with rotatary handle . Make of MCCB : L&T, Cat Part No. CM92109OONOG or equivalent in Legrand / Seimens/ Schinder. ( ii) MCCB 160 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 02 Nos with rotatary handle (one operational+one Spare ). Make of MCCB : L&T, Cat Part No. CM92108OOP1OG or equivalent in Legrand / Seimens/ Schinder. (iii) MCB 40 Amp Four Pole (FP) ultimate breaking capacity 10KA , C curve -02 No (iv) MCB 25 Amp Double Pole (DP) ultimate breaking capacity 10KA ,C curve -02 No
Note:- (i) All MCCB/MCB should be of Make : L&T/ Legrand /Schnider/Seimens. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 2.0 mm thick CRCA sheet with angle iron frame of 75 x 75 x 6 mm , single door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-43 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 1200 Amps (Size of copper strip should not be less than 75 x 10 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel all as specified with supply and fixing the following.
ITEM 16 CONTD.... (A) Incoming (i) ACB 800 amps rating, 4 pole ,415 V, AC, 50 HZ, draw out type, Microprocessor Based, Manuly operated type, Breaking capacity Icu = Ics = Icw (1Sec) --- 01 Nos Make of ACB : L&T , C Power, Micro processor based SR 18 G , Cat Part No. SL 96062 or equivalent in Legrand / Seimens/ Schinder. (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp, Neon type for three phase (v) Slector switch - 2 Nos (B) Outgoing (ii) MCCB 250 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 200-250 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA --- 02 Nos with rotatary handle .Make of MCCB : L&T, Cat Part No. CM92109OOP1OG or equivalent in Legrand / Seimens/ Schinder. (ii) MCCB 200 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 160-200 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 02 Nos with rotatary handle. Make of MCCB : L&T, Cat Part No. CM92109OONOG or equivalent in Legrand / Seimens/ Schinder.
ITEM 16 CONTD.... (iii) MCCB 160 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA - 01 Nos with rotatary handle. Make of MCCB : L&T, Cat Part No. CM92108OOP1OG or equivalent in Legrand / Seimens/ Schinder. (iv) MCB 40 Amp Four Pole (FP) , ultimate breaking capacity 10 KA , C curve - 02 No (v) MCB 25 Amp Double Pole (DP) , ultimate breaking capacity 10KA , C curve - 02 No Note:- (i) All MCCB/MCB should be of Make : L&T/ Legrand /Schnider/ Seimens. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB. (v) The copper extesion link from bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders. (vi) Independent Amper meter with CTs to be provided for each out going feeder. (vii) Spreader terminals and Phase barriers to be provided with all MCCB`s
M&L earthing complete with copper earth plate electrode 600mm x 600mm x 3 mm thick burried directly in ground (Earth pit not less than 3 m deep below ground level) with top edge of the plate not less than 2.25m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in any type of soil, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land, construction of PCC earth pit chamber of size 900 x 900 x 450 mm , RCC chamber cover plate, wire mess, funnel, test point, 32 mm dia GI protection pipe light grade and 40 mm GI medium grade peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Note : (i) Fresh agriculture soil (free from forigen particle)will be used for filling the dug as required to achieve the desired resistance from out side (ii) Copper strip will be laid below 100mm from ground level and connected to test point through plinth protection. (iii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor through double nut bolt and brazing of joints, argiculture soil to be bring from out side deemed to be included in the item rate. (iv) Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately.
Supply and fixing copper strip of size 20 x 3 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour ) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge.( Note : (i) Cost of insulator, brass nut bolt and washer deemed to be included in unit rate of item. (ii) Insulator to be provided on every 50 cm for fixing the strip).
M&L Earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried direct in ground (Earth pit not less than 3.00 m deep below ground level) with top edge of the plate not less than 2.25 m below ground level connected to GI earth strip 32 X 6 mm as earth lead by means of GI nut bolts and double washers as shown in electrical plate No 3 connected to earth test point including necessary excavation in any type of soil, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land, construction of PCC earth pit chamber of size 900 x 900 x 450 mm , RCC chamber cover plate, wire mess, funnel, test point, 40 mm dia GI light grade protection pipe , 40 mm GI medium grade peforated pipe for watering etc complete and testing on completion all as specified and directed by Engr-in-charge. Note : (i) Fresh soil will be used for filling the dug as required to achieve the desired resistance from out side (ii) GI strip will be laid below 100mm from ground level and connected to LT panel through plinth protection. (iii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor through double nut bolts and washer and argiculture soil to be bring from out side deemed to be included in the item rate. (iv) GI strip upto 7.5 RM will be included in the item rate and beyond 7.5 RM will be measured seperately.
Supply and fixing GI strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour suitable for mounting 32 mm strip ) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as specified and directed by Engr in Charge.( Note : (i) Cost of insulator, GI nut bolt and washer deemed to be included in unit rate of item. (ii) Insulator to be provided on every 50 cm for fixing the strip).
S&F for Test point junction box made of polycarbonate (without terminal block) of size 130x180x77 mm, IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation. Make : Hensel- Cat part No. KF 1000 H
S & F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and as directed.
Supply,fixing, installation, commessioning and testing Servo controlled Voltage stablizer For automatic operation of 150 KVA capacity confiriming to BIS 9815: Part 1 : 1994 reaffirmed 2009, 3Phase, 50 HZ, Naturally oil cooled, Indoor type, unbalanced type, copper wound, with digital display type, Relay free smooth and silent operation with 1st fill of tramsformer oil (IS335:1993, reaffirmed 2005), IP 42 designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second having following specification complet all as specified. (i) Input Voltage 300 Volt -480Volt. (ii) Output voltage stabilized at 415 V + 1%(Adjustable). (iii)Rated frequency 50 HZ. (iv) No distortion wave form. (v) Respond time shall not to exceed 10 Milisecond. (vi) Sensitivity (+ ) 1 %. (vii) Rate of correction 8 Voilt /Second for single Phase and 20 Volt / Second for Phase to Phase. (viii) No load losses less than 0.5% and full load losses less than 2.5%. (ix) Duty cycle Continuous 24 x7. (x) Efficiency more than 95%. (xi) Type of load : 3 Phase, unbalance type. (xii) Digital Volt meter/Ampere meter). Protection : (i) Overload/ Short circuit protection. (ii) High /Low voltage cut off. (iii) By pass arrangement in case of emergency. (iv) Single Phase sequence change protection.
Supply,fixing, installation, commessioning and testing Servo motor operated single phase line voltage corrector, naturally air cooled, having copper wound transformer, indoor type & designed for input variation between 140 V to 280 V with output voltage stabilized at 220 V with accuracy of ± 2.5% and of capacity 5 KVA , having electrnic control circuit, low voltage cut off and high voltage cut off feature, single phase preventor, time delay and toggle switch provided to by pass complete including making all connections all as speicifed.
Supply Installation, fixing, testing and commissioning of Split Air conditioner unit of 2.0 TR capacity (split type unit comprising of indoor and outdoor unit white colour) electric driven, Signal Phase, 230 Volt (220-240 Volt), 50 Hz and with inbuilt air ioniser and plasma fitter for better indoor air quality, having latest model of AC with 5 Star BEE rating, having ISEER value not less than 5.0 Wh, Split inverter AC, having inverter rotary compressor, having Round tube Plate fin copper tube condensor with hydrphillic coating for better protection of condenser from corrosion with R-32 refrigerant (non CFC gas), cooling capacity shall be 24000 BTU/hr including necassary fixing arrangement complete (indoor unit at suitable place and hight inside the room and outdoor unit at suitable place outside the room) including metallic bracket with fixing bolts for outdoor unit , insulated piping,making all electrical connections etc. complete all as specified and directed by Engr-in- Charge.
Supply, install and testing 5 KVA wall mounted Voltage stabilizer for automatic operation, conf to IS 8448 Latest, single phase, naturally air cooled, indoor type & designed for input variation between 120 V to 280 V with output voltage stabilized at 220 with accuracy ± 1% and speed of correction 8 Volts per second, with LED display for digital voltmeter, having copper wound transformer, inbuit thermal overload protection, automatic high and low voltage cut off, time delay system, complete all as specified and as directed.
Supply Installation, fixing, testing and commissioning of Split Air conditioner unit of 1.5 TR capacity (split type unit comprising of indoor and outdoor unit white colour) electric driven, Signal Phase, 230 Volt (220-240 Volt), 50 Hz and with inbuilt air ioniser and plasma fitter for better indoor air quality, having latest model of AC with 5 Star BEE rating, having ISEER value not less than 4.6 Wh, Split inverter AC, having inverter rotary compressor, having Round tube Plate fin copper tube condensor with hydrphillic coating for better protection of condenser from corrosion with R-32 refrigerant (non CFC gas), cooling capacity shall be 18000 Btu/h including necassary fixing arrangement complete (indoor unit at suitable place and hight inside the room and outdoor unit at suitable place outside the room) including metallic bracket with fixing bolts for outdoor unit , insulated piping, making all electrical connections etc. complete all as specified and directed by Engr-in- Charge.
Supply, install and testing 4 KVA wall mounted Voltage stabilizer for automatic operation, single phase, naturally air cooled,conf to IS 8448 Latest, indoor type & designed for input variation between 160 V to 260 V with output voltage stabilized at 220 with accuracy ± 1% and speed of correction 8 Volts per secondwith LED display for digital voltmeter, having copper wound transformer, inbuit thermal overload protection, automatic high and low voltage cut off, time delay system, complete all as specified and as directed.
Note for Item No. 25 and 27 above: (i) Air conditioner shall be initial filled/charged with refrigerant of specified quantity. (ii) Additional refrigerant pipes including filling of additional qty of refrigerant as required on site from outer unit to indoor unit beyond as supplied by manufacturers is deemeed to be included in AC unit rate. (iii) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit. (iv) Split type AC unit to supplied with cordless remote control for operation (v) The condenser unit shall be copper tube with hydrphillic coating for better protection of condenser from corrosion. (vi) The refrigerant to be used shall be R 32 (Non CFC compliance) as per latest technology. (vii) The spilt AC unit shall be latest model having valid 5 Star BEE rating as on date of installation. (viii) Contractor shall submit the brochure of AC with detail technical specification and take approval of GE before procurement. (ix) Contractor shall submit the Purchase voucher, Test certificate and warrranty certificate of AC. Contractor shall obtain the Warranty certificate from manufacture and to be submitted to department. (x) All the necessary accessories and T&P required on site for installation of indoor and out door unit shall be provided by contractor. (xi) Installation of AC to be done by manufacture authorised repesentative. (xii) Compresssor of unit shall be of min 7 yrs manufacture warranty. Contractor shall submit the warranty cetrificate to department. (xiii) Noise level (operation sound) of unit shall not be above 52 dB at high cooling. (xiv) All civil work for drilling the hole in wall of any thickness on site for laying the refrigerant pipe line, and electrical cable from out door unit to indoor unit of AC and to make good to match the surface as existing to be done by contractor with out any extra cost. (xv) Power supply electric cable to be provided with 15 Amp metal clad Pin top and to connect with source of supply by the contractor without any cost.
M & L point wiring with 4.0 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, on independent board and with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly, ISI marked of green colour for continous earth to connect in industrial metal clad socket all as specified and directed. NOTE:- Point wiring distance upto 20mtr from DB to be consider in point wiring beyond that it is considered and measured in submain wiring.
S & F single pole and neutral enclosure with two pin and earth plug and socket including top complete with 20 Amps SP MCB, C curve, 10kA, 240V all as directed by Engr-in-Charge. NOTE:- Enclosure and MCB shall be of same make.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB SPN 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge.
S&F cable route marker made up of cast iron (Round Dia ) of 100mm round plate 3 mm thick fixed on MS angle iron of size 25 X 25 X 5 mm ,800 height fixed in ground over the cable route with PCC 1:2:4 complete all as specified and directed by Engineer in Charge
Neha Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .