Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.9 L+₹71,650 (7.04%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L2 | Rejected-Finance Highly quoted | |
| 3 | L3₹12.1 L+₹1.9 L (18.6%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance Highly quoted |
Tender Value
₹11.5 L
EMD Value
₹23,040
Closing Date
13 Mar 2021, 6:00 pmClosed
AGM(E-E)
Asstt.Gen.Manager (E-E), Airports Authority Of India, Regional Head Quarter, W/R, Integrated operational offices building, 5th floor, Parsiwada, Vile Parle (East), Mumbai-400099
Annual Maintenance Contract of Fire Hydrant, Sprinkler system and Ventilation system at Integration Operational offices building, Mumbai for 2 Years (2021-23)
2021_AAI_71898_1
AAI/Ops-off/MUM/AGM-EE/NIT9/21
Open Tender
Electrical Works
Item Rate
730 days
Mumbai
As per tender document
20 documents required · 20 mandatory
₹1,120
Yes
₹23,040
Yes
7 Jun 2021
4 Mar 2021
15 Mar 2021
5 Mar 2021
13 Mar 2021
5 Mar 2021
5 Mar 2021 - 8 Mar 2021
Amount
Annual Operation & Maintenance of Fire Hydrant, Fire Sprinkler system & Ventilation System including all fire pumps i.e Main Hydrant pump, Sprinkler pump, Jockey pump & Booster pump, Internal and External hydrants, all valves, Hose reel, Hose Boxes, Fire LT Panel, Diesel pump (Except Diesel Engine), sprinklers, fire alarm valve, SS braided flexible, Smoke Exhaust Fans, Jet Fans, In-Line fan for Atrium, Exhaust and Ventilation Panel etc as required. Work includes preventive maintenance of pumps, ventilation fans and other equipments, attending complaints/faults/breakdown and taking rectification action to ensure serviceability & satisfactory working condition of system, maintaining water pressure as required including testing of fire hydrant and fire Sprinkler system and ventilation system and maintaining records by deploying qualified manpower in General shift (shift of eight hours) on all working days including saturdays, holiday except sunday as per special conditions of contract and additional special conditions of contract.
Painting of various MS/GI pipe line of Fire Hydrant system and Fire sprinkler system including Pumps, Hose boxes, by one and more coat of red oxide metal primer and synthetic enamel paint of approved brand and colour including cleaning and scrapping of old paint with metal brush/ emery paper including numbering of hose boxes and writing the names on the pumps and panels with the paint complete etc. as required details as below :
Main Hydrant Pump (75 KW)
Main Sprinkler Pump (75 KW)
Jockey Pump (7.5 KW)
Fire Engine Pump (83 HP)
Booster Pump (12.5HP)
M.S/GI pipe (Size 25 mm to 200 mm)
Hose Box (900 x 600 x 500 mm) including MS supports.
Rewinding of 7.5 KW capacity 3 phase, 415 V AC supply Jockey Pump motor with suitable gauge copper wire including overhauling/servicing, replacement of ball bearings, varnishing, baking, dismantling, re-assembling, including transportation from site to contractor’s workshop & back to site, loading, unloading, testing and commissioning etc. complete as required. (Credit towards dismantled copper wire & damaged parts which shall be replaced may be considered the property of contractor accordingly rate shall be quoted)
Supply of 15 mm standard response, quartzoid bulb Pendent type sprinkler of rating 68 °C.
Supply of 15 mm standard response, quartzoid bulb Upright type sprinkler of rating 68 °C.
Supply of 15 mm standard response, quartzoid bulb side wall type sprinkler of rating 68 °C.
Supply of UL approved SS Braided flexible drops 25 mm dia capable to withstand maximum working pressure of 175 PSI, minimum length 1.5meter .
Supply & Fixing of following size cast Iron foot valve with strainer for negative suction complete etc. as required.
200 mm dia
80 mm dia
Supply & Fixing of Pressure Switch including connection complete etc. as required. (make: Danfoss, Model : KP 36 or Equivalent approved make)
Supply & Fixing of pressure gauge of 100 mm dia , 0-21 kg/sq.cm range with 15 mm dia stop cock valve complete etc. as required.
CENTRE TAP ENGINEERING
Manish Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .