Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.3 L+₹4.9 L (17.8%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹33.8 L+₹6.3 L (23.1%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹34.4 L+₹6.9 L (25.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.5 L+₹11.1 L (40.3%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹36.9 L
EMD Value
₹73,800
Closing Date
8 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair and maintenance to cooling appliances and other allied works at Old Cantt and Fort Cantt Allahabad.
2022_MES_506251_1
8538/E8
Open Tender
Civil Works
Item Rate
270 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹73,800
Yes
7 Apr 2022
7 Feb 2022
10 Mar 2022
7 Feb 2022
8 Mar 2022
1 Mar 2022
7 Feb 2022 - 14 Feb 2022
60 days
Amount
Checking of Air conditioner at site, transporting to workshop in E/M yard, dismantling of Air conditioner and taking down of compressor of air conditioner window/Split type 1.5/2.0 ton capacity cutting & brazing of suction/ discharge tubing complete all as specified & directed. Note :- (i) Air conditioner shall be repaired within 05 days from the day of taking down. (ii) Delay in repair and refixing after 05 days a sum of Rs 1000/- per air conditioner shall be levied upon contractor and deduction from contractor payment.
Supply only sealed compressor unit of capacity of 1.5 Ton window type air conditioner/ split type AC complete all as specified & directed. Make : ACCEL/ CARRIER/ Kirloskar Copland / VOLTAS/Copland as approved by GE.
Supply only sealed compressor unit of capacity of 2 Ton window type air conditioner/split type complete all as specified & directed. Make : ACCEL/ CARRIER/ Kirloskar Copland / VOLTAS/Copland as approved by GE.
Gas charging in Air conditioner window/Split AC 1.5/2 Ton Capacity with appropriate quantity of refrigerant Gas after fixing new compressor including replacement of filter strainer and testing complete all as specified & directed.
Detecting the cause of leakage rectifying the same and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity suitable for window type AC/ split type AC including testing for smooth functioning complete all as specified & directed.
Repair/ Servicing to window type/split type AC 1.5 ton/2 ton capacity any make by dismantling the blower motor, condenser fan motor, fan blade, blower drum any type etc cleaning and servicing of serviceable parts, replacement of wiring kit, knob and unserviceable spare parts etc , replacement of insulation foam 3 mm thick, air filter and re- assembling the serviceable spare parts etc and testing for smooth functioning and re-installation at site or deposit in MES store yard complete all as directed by Engineer-in-Charge. Note :- (i) Air conditioner shall be repaired within 05 days from the day of dismantling / taking down. (ii) Delay in repair and refixing after 05 days a sum of Rs 1000/- per air conditioner shall be levied upon contractor and deduction from contractor payment. (iii) Spare parts required shall be measured and paid seperatly as 'Supply only' under respective item.
Supply only following spare parts of window type AC/split type AC :-
Supply only Running capacitor 36/45/50 + 6mfd ± 5%, 440 Volt AC. Make : Usha/ Asian/ Crompton greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only Relay for window AC. Capacity 1.5 T/2 T
Supply only Thermostate
Supply only Blower motor, single phase, 230Volt AC for window air condtioner. Make : KIRLOSKAR/ JYOTI/ BEACON as approved by GE.
Supply only Blower fan blade made of plastic for air conditioner.
Supply only Condensor fan blade made of plastic for window or split air conditioner.
Supply only condensor motor 1/10 HP single phase 230 V AC electric supply for outdoor unit of split
Supply only condensor motor 1/20 HP single phase 230 V AC electric supply for outdoor unit of split
Supply only PLC unit for split type air conditioner as same make and capacity. Make : CARRIER/ VOLTAS/ ACCEL /LG/Samsung/Blue Star as approved by GE.
Supply only Split AC contactor single phase 230V of suitable capacity for Split AC 1.5 Ton/2 Ton including coil. Make : CARRIER/ VOLTAS/ ACCEL as approved by GE.
S&F sub main wiring with two single core PVC insulated & unsheathed cable 6.0 Sqmm (nominal area) FR type multi stranded copper conductor drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring with and including cutting chases and making good of disturbed surfaces & applying finishes & including 6 sqmm FR type PVC insulated unsheathed cable multistranded copper conductor as earth wire connected to common earth as per IS including taking down existing complete wiring complete all as specified & directed. NOTE : NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
M & L Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of PVC casing / caping 25mm dia and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly and making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
S&F in repair Sheet metal enclosure with three pin earth plug and socket complete with MCB 20 Amp Single Pole 240 Volt 'C' curve and ultimate breaking capacity 10 KA including taking down existing unserviceable MCB DB complete all as specified & directed.
Checking of water cooler any capacity at site, transporting to workshop in E/M yard, dismantling of water cooler and taking down of compressor any capacity and type cutting & brazing of suction/discharge tubing complete all as specified and derected.
Supply only new sealed compressor unit of water cooler 120 Litre cooling capacity and make for suitable existing water cooler. MAKE: Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG.
Supply only new sealed compressor unit of water cooler 40 Litre cooling capacity and make for suitable existing water cooler. MAKE: Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG.
Gas charging in water cooler with appropriate quantity of refrigerant gas after fixing new compressor including replacement of filter strainer and testing complete all as specified & directed.
Labour only for Detecting & rectification of leakage and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity of refrigerant suitable for water cooler including replacement of fitter strainer testing for smooth functioning complete all as specified & directed.
Labour for Disconnecting of electric connection and water connection of water cooler, opening the condensor fan motor blade, electrical accessories and spare parts of system, carefully servicing of serviceable parts, replacement of un-serviceable parts oiling of fan motor etc, reassembling all spare parts including rewiring of internal connection of water cooler, re-connecting elec& water cooler connection ,testing and commissioning complete. Notes :- (i) Warn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item. (ii) Replacement of nut & bolts washers deemed to be included in unit rate. (iii) Minor repair of chassis by brazing/ welding work deemed to be included in unit rate.
Supply only following spare parts for water coolers:-
Supply only running capacitor 25/36 mfd ±5% 440 Volt AC supply. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only running capacitor 20/10 mfd ± 5% 440 Volt AC supply. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only starting capacitor 60/70 mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only starting capacitor 40/50 mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only starting capacitor 80 mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only start Relay for water cooler any capacity.
Supply only over load protector same make and capacity.
Supply only thermostate
Supply only condensor motor 1/35 HP single phase 230V.
Supply only condensor motor 1/24 HP single phase 230V.
Supply only Condensing coil
Supply only plastic drain hose pipe (not exe 1.0 Rm)
Supply only Push cock/lift cock brass with chromium plated.
Supply only capillary Tube (not exceeding 0.60m).
Supply only Float Valve 1/2 " including assembly brass made
Detection and rectification of leakage of storage tank of water cooler by brazing, soldering/ welding as required at site or at work shop and unserveciable spare parts such as Nipple adaptor, Push cock, float valve & Bush, nut, bolt, washer, rubber/plasting packing are included in unit quoted rates not any claim on this account will be replaced for smooth functioning & testing for leak proof complete all as specified and directed.
M&L for spray painting of water cooler after preparation of old surface of water cooler with one coat of synthetic enamel paint as approved complete all as specified and directed.
M&L replacement of drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting including refixing back complete all as specified and directed.
Repair maint of refrigerator, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator, re-assembling all spare parts including rewiring of internal connection of Fridge, testing and commissioning complete all as specified and directed Notes:- (a) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item of BoQ. (b) nut/bolt & washers etc deemed to be included in unit quoted rate. (c) Minor repair of chassis of brazing/welding work deemed to be included in unit rate. (d) Refrigerator shall be repaired within 05 days from the day of taking down. (e) Delay in repair and refixing after 05 days a sum of Rs 1000/- per Refrigerator shall be levied upon contractor and deduction from contractor payment.
Replacement of unserviceable compressor from refrigerator any capacity by cutting and brazing suction/ discharge tubing including charging of required qty of refrigerant gas complete including testing and commissioning for smooth functioning and satisfaction of Engineer-in-Charge. Note: (i) Compressor & spare parts shall be measured and paid separately under respective item of BoQ supply only item. (ii) Replacement of nut & bolts washers deemed to be included in unit quoted rate. (iii) Minor repair of chassis of brazing/welding work deemed to be included in unit quoted rate. (iv) Refrigerator shall be repaired within 05 days from the day of taking down. (v) Delay in repair and refixing after 05 days a sum of Rs 1000/- per Refrigerator shall be levied upon contractor and deduction from contractor payment.
Detecting & rectifying of leakage and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity suitable for refrigerator including testing for smooth functioning and satisfaction of Engineer-in-Charge.
Supply only sealed compressor unit of refrigerator 160 to 240 Litre cooling capacity complete all as specified and directed.
Supply only sealed compressor unit of refrigerator 280 to 340 Litre cooling capacity complete all as specified and directed.
Supply only following spare parts for refrigerators suitable for existing size and make at site:-
Supply only Relay
Supply only Over load protector
Supply only Thermostate
Supply only Cooling coil
Supply only Condensing coil
Supply only Bulb Holder
Supply only Bulb pin type /screw type 15 Watt
Supply only Door switch
Supply only Chilled tray
Supply only Vegitable tray
Supply only Bottle supporter
Supply only Capillary Tubeing (note exceeding 0.40m)
Opening of the automatic voltage stabilizer Capacity 5 KVA/4 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified and directed by Engineer-in-Charge
Opening of the automatic voltage stabilizer Capacity 2KVA/ 3 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified and directed by Engineer-in-Charge
Opening of the automatic voltage stabilizer Capacity single phase 230V 1 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified by directed by Engineer-in-Charge. Notes for item No. 26 to 28 of BoQ :- (a) Worn/ unserviceable spare parts to be replaced with new spare parts shall be measure and paid seperately under respective item of BoQ (b) Providing flexible 3 core sheathed cable of size 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM which will be deemed included in the unit quoted rate.
Supply only following spare parts suitable for voltage stabilizer of any make and any capacity :-
Supply only Volt meter (0-300 volts).
Supply only Control relay.
Supply only IC controlled circuit for 5 KVA/4 KVA.
Supply only IC controlled circuit for 3 KVA.
Supply only control transformer rating input 170 to 250 Volt and output 230 Volt.
Supply only low/high voltage cut off and TDR system.
Supply only main transformer for 5 KVA/4 KVA.
Supply only main transformer 3 KVA
Supply only main transformer 1 KVA
Opening of the Desert Cooler of any capacity and make, dismantling of complete items and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, opening of Fan motor from their brackets, scraping out of old paint of complete body (internally & externally) of Desert Coolers making good, smooth surface and applying spray painting with one coat of synthetic enamel paint for external surfaces/ internal surface, replacement of wooden wool pad - 3 Nos and fixing of Fan Motor and Pump, replacement of internal wiring and rotary switch with pump and Fan motor connection and testing after repair complete. Note: (i) Overhauling/Oiling of fan motor, Vertical pump replacement of Nuts, bolts washers/elbow, if required shall be deemed to be included in unit quoted rate. (ii) Cost of replacement of grass pad deemed to be included in quoted rate. (iii) Unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item. (iv) Minor repair of chassis of brazing/welding work deemed to be included in unit rate. (v) Provide PVC Sheathed cable of 23/.0076 up to 1.5 meter in replacement if required will be deemed included in the unit rate.
Supply Only following spare parts suitable for Desert Coolers existing make or existing capacity:-
Supply only fan motor of 1/6 HP to 1/10 HP 230V AC electric of same capacity and same make
Supply only Blade for kit Fan.
Supply only MS Bracket for kit Fan Motor
Supply only Submersible Pump set suitable for desert coolers of fractional H.P. Make : CG/Bajaj/Havells/Vansal or Summar cool/ Zolta (Khaitan).
Supply only Rotory Switch
Supply only Piano type Switch, 5 Amp 230 Volt AC
Supply only Front Directional Grill
Supply only PVC pipe 10 mm dia flexible
Supply only Side panel made out of PGI Sheet 1 mm thick of size not less than 0.5 m width and 0.7m height complete.
Supply only Storage tank made out of PGI Sheet 1 mm thick of size not less than 0.7 m X 0.7M and height 0.2m complete.
Rewinding of fan motor Kit fan 450 mm sweep with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishing complete all as specified and directed by Engineer-in-Charge. Notes :- (a) removing the defective fan & rectifying after repair including removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair/servicing including oiling, greasing, washer, lock bolts, connector etc. depositing the fans to AGE E&M. office/ yard and testing complete to the entire satisfaction of Engineer-in-charge.
Supply only metal bush bearing for ceiling fan/ exhaust fan/ cabinet/ pedestal fan of any make/ sweep complete
Supply only capacitor 3.15/ 4 mfd + 5% 440V AC. Make: Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE
Supply only PVC sheathed white colour three core copper flexible cable of size 23/.0076 complete.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for Ceiling Fan of 1200 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for ceiling Fan of 1400 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 450 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 380 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 300 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 225/230 mm sweep size of fans of any make complete all as specified and directed.
Rewinding of fans complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for cabin/padestal Fan of 400 mm sweep size of fans of any make complete all as specified and directed. NOTE for item No. 36 to 42 of BoQ : Collection of fan from AGE E&M office under contractor own arrangement for repair the same, removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair including oiling, greasing, washer, lock bolts, connector etc.replacement of worn out/ unserveciaval parts, if required to be included in unit quoted rate depositing the fans to AGE E&M. office yard and testing complete to the satisfaction of Engineer-in-charge (Supply of spare parts will be measured and paid seperately under respective items of schedule).
Supply only Ball bearing size No. 6201 for ceiling/exhaust fan
Supply only Ball bearing size No. 6202 for ceiling/exhaust fan
Supply only Ball bearing size No. 6203 for ceiling/exhaust fan
Supply only capacitor 2.5 mfd rating complete all as specified and directed. Make: Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE.
Supply only rotor shaft for Ceiling/exhaust fan of any make/sweep complete all as specified and directed.
S&F in repair twisted two core copper flexible cable of size 23/.0076 from connector to the ceiling rose complete all as directed
Taking down from site, transporting to workshop and Over hauling only ceiling fan of any sweep/make i.e. opening of fan and cleaning ball bearing, filling grease/oil and changing of nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling including refixing at site complete all as specified and directed. Notes:- (i) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item of BoQ. (ii) Replacement of nut, bolts & washers deemed to be included in unit quoted rate quoted by contractor. (iii) Minor repair of chassis by brazing/ welding work deemed to be included in unit quoted rate. (iv) Ceiling / exhaust / Cabin fan shall be repaired within 05 days from the day of taking down. (v) Delay in repair and refixing after 05 days a sum of Rs 200/- per Ceiling / Exhaust /cabin fan shall be levied upon contractor and deduction from contractor payment.
M & L for spray painting of fan of any size with two coat of synthetic enamel paint (white) after cleaning of body, blades, down rods from dust, dirt, oil, grease etc. including re-writing MES fan Nos. on the body of fan, using black paint complete all as specified and directed.
Supply only canopy for ceiling fan suitable for any sweep / make as required complete all as specified and directed.
Supply only nut bolt of size 8mm dia 100mm length complete all as specified and directed.
Supply only rubber reel for ceiling fans complete all as specified and directed.
Supply only CLIP for down rod complete with rubber reel and nut bolts for ceiling fans complete all as specified and directed.
Supply only down rod of size 1 ft/2ft for ceiling fans complete all as specified and directed.
Supply only fan blade aluminium painted with white colour and suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Engraving of MES No. on ceiling fans complete all as specified and directed.
S&F ventilator fans AC single phase 230/240V of size 230 sweep "metallic range" complete including making holes and necessary make good disturbed surfaces complete all as specified and directed. Make : Havells Cat part No. Ventil air DSP
S&F in repair fan hook made out of 40x6 mm flat iron suitable for hanging of ceiling with proper size nut bolt and washers to be fixed in pipe of 40 mm bore dia complete all as specified and directed.
S&F stepped socket type electronic fan regulator flush type AC 230 volt 120 W suitable for any type of ceiling fan complete all as specified and directed.
S&F GI tubing 40mm bore medium grade in required length and grouting in wall for hanging of ceiling fan all as directed by Engr- in -Charge ande making good disturbed surface of wall to match existing surface complete al as specified and directed.
Taking out old PVC /HDPE fins cooling tower, cleaning inside and outside , refixing new PVC /HDPE fins for proper cooling , size of cooling Tower 1250mmx1250mmx1400mm,including replacement of Nozzel , complete all including testing complete all as specified and directed.
Taking out old unserviceable compressor of 5.5 Ton capacity AC plant make of AC plant : Voltas including disconnecting all electrical and gas connection and supply and fixing new tharmetically sealed compressor reciprocating type suitable for R-22 of same capacity connecting with gas and electric connections complete all including testing complete all as specified and directed. Make : Kirloskar/copeland
Taking out old unserviceable draft fan of cooling tower and supply and fixing draft fan 450 mm sweep heavy duty 3 phase 440 V AC electric supply 3 HP capacity on cooling tower including necessary fixing arrangement by weilding /MS nuts, bolts etc including electrical connection and testing complete all as specified and directed
Taking out old unserviceable booster pump (condensor pump) 3 phase 440 v AC electric supply operated 3 HP capacity centrifugal type, disconnecting all electrical and water supply connections and rewinding burnt copper winding with enamelled copper wire of existing guage and turns including replacement of bearing and repair to pump by dismantling all parts and replacement if bearing, water seal, defective shaft complete all as specified and directed.
Taking out old unserviceable booster pump(water pump) 3HP capacity centrifugal type , disconnecting all electrical and water supply connections including replacement of bearing and repair to pump by dismantling all parts and replacement if bearing, water seal, defective shaft complete all as specified and directed
Supply only refrigerant gas (R-22) in sealed container with cylinder and valve duly tested complete all as specified and directed.
Cleaning of condensors of 5.5 Ton AC plant by disconnecting all gas connections, mannually or mechanical scrubbbing , scrapping by using suitable chemical solution complete all as specified and directed
Supply and fixing in repair fan belt suitable for blower motor 3 HP capacity complete all as specified and directed.
Cleaning of AHU inside and outside including taking out all Micro filter/Mesh filters/fibre filter by mannual cleaning of all filters and AHU housing with suitable chemical solution complete all as speicified and directed
M&L for leak testing of complete system of AC plant and making leakproof including repair of leakages in AC plant complete all as specified and directed.
Gas charging of AC plant with R22 Gas after leakage , repair and testing complete all as specified and directed. (Note : 1. Gas used for charging will be used from item No 67 above. 2. All T&P required shall be provided by Contractor.
S&F in repair of copper tube 1/8" size of refrigeration line and gas weilding complete all as specified and directed
S&F in repair 50mm bore Gun metal valve with iron wheel spindle including necessary cutting and threading pipe complete all as specified and directed
M&L for scrapping , scrubbing , removing rust , preparation of old surfaces, applying one coat of synthetic enamel paint inside and outside on central AC plant 1x11 TR capacity including compressor, condensor, water pumps, blower motors, pipe lines etc all as per existing colour code complete all as specified and directed.
S&F in repair pressure gause round dial boudon type range (0-7 Kg/Cm2) Complete all as specified and directed
sethi tradres
8M/S TIWARI and SONS
Raj and satish enterprises
DINESH ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .