Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹32.6 L
EMD Value
₹65,300
Closing Date
17 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Manav Pant, CWE
HQ CWE (AF) Chakeri, Kanpur
SPL REPAIR REPLACEMENT OF BER ACS AND COOLING APPLIANCES AT 24 ED UNDER AGE I AF MANAURI
2025_MES_741504_1
CWE(AF)/CHK/MNR/T-37 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Manauri
Please refer tender documents
7 documents required · 7 mandatory
₹500
AGE(I) Manauri
₹65,300
31 Dec 2025
25 Nov 2025
24 Dec 2025
25 Nov 2025
17 Dec 2025
10 Dec 2025
Supply, installation and testing Air cooled Inverter based split AC 1.5 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode) Air conditioner will have following conditons :- (a) Refrigerant - R-410 a/R-32 (b) EER-5 Star Rating (c) Tonnage - 1.5 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments
Supply, installation and testing Air cooled Inverter based split AC 2.0 TR unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C± 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410 a/R-32 (b) EER-5 Star Rating (c) Tonnage - 2.0 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments
Note for Item No 1 and 2: The cost of following items deemded to be included in quoted rate. (a) Copper pipe duly insulated between indoor/outdoor unit upto length 10mtr for each unit (b) MS Bracket for outdoor unit duly power coated with fixing arrangement. (c) Making of hole in walls including civil work, sleeves and making good to the disturbed surface/wall as per existing sarface. (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) PVC round sheathed copper cable of suitable size for connecting Indoor and outdoor unit upto supply point as per site requirement (f) Contractor will submit manufacturer's warranty certificate to the GE.
Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 Ltrs and nominal cooling capacity 40 Ltrs complete with all accessories complete all as specified and directed. Note: Contractor will submit manufacturer's warranty certificate to the GE.
Supply, installation, commissioning of Glass Top Deep Freezer double door storage capacity 320 Ltrs, single phase 240 volt, 50 Hz complete with all accessories complete all as specified and directed. Note: Contractor will submit manufacturer's warranty certificate to the GE.
Supply, installation, testing and commisioning of refrigerator double door storage capacity 270 Ltrs 5 star rated, single phase, 240 Volt, complete all as specified and directed. Note: Contractor will submit manufacturer's warranty certificate to the GE.
Taking down complete AC of capacity 1.5/2.0 TR including disconnecting all electrical connection, copper piping and deposit to MES store yard complete all as specified and directed.
Supply and installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180V to 250V with voltage stabilzer at 230V with Digital display, accuracy of (+) 2.5% and capacity 4 KVA complete all as specified and directed.
Taking down old unsv sub main wiring and M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC conduit of size 19/20 mm (ISI marked) including PVC accessories (conduit on wall complete including making good to disturbed surface etc)complete etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6.00 Sqmm cable and one run of 6.00Sqmm earth wire & 20 mm PVC conduit shall be measured as one unit length complete all as specified and directed.
Supply and fixing sheet metal enclosure with socket and plug top single pole and neutral enclosure with two pin and earth plug and socket complete with one MCB 20-25 Amp 'C' series single pole complete with connection complete all as specified and directed.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as specified and directed.
Supply and fix MCB single pole and neutral (SP&N) 40 to 63 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed.
S&F MCB single pole (SP) 20 to 25 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 25 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands complete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under respective items herein
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8 cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose.
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cushioning in trenches for cable protection complete all as specified and directed.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.04 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
BOQ_830304.xls
BOQ • 1.02 MB
TENDERT37BERACANDCOOLING.pdf
Tender Documents • 1.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .