| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹27.9 L+₹3.9 L (16.4%)Rejected-Finance C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L2 | Rejected-Finance Not Being Lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
3 Jul 2020, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GORAKHPUR
GE (AF) GORAKHPUR-273008
CERTAIN E/M AND B/R SANCTIONED WORK AT 4AFSB VARANASI UNDER GE (AF) STN GORAKHPUR
2020_MES_347256_2
8673/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) GORAKHPUR
Please refer Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) GORAKHPUR
₹56,000
Yes
18 Aug 2020
6 Jun 2020
4 Jul 2020
6 Jun 2020
3 Jul 2020
21 Jun 2020
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 ( 40mm graded stone aggregate ) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
All as above but except brick
M&L for RCC (1:2:4) type B1 ( 20mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, and plinth beams, Rcc band and similar work flat, rough finished surface concrete etc. Complete all as specified and directed.
S & F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as above but 8 mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in coping, lintels of span up to 1.5m ,bed blocks for fencing post hold fasts, etc including weathering slightly rounded or chamfered angles throating and including necessary form work and finishing the exposed surfaces complet all as specified and directed.
S&F for Mild steel work such as angle iron post , flat iron in fencing including cutting as making doubble swan neck i.e. "Y" shaped including welding with proper overlapping & Welding MS Plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to Fe 290 grade E-165 complete all as specified and directed.
S&F for 610 mm dia punched tape concertina coil (effective dia 550 mm at stretch length of coil 6 m) two handle and spikes at both ends of ends of coil with dove tail clips ( 18 SWG) including razor wire ( 07 No) 6m length in each wire with medium size,barbed length 20 mm and barbed 14mm incuding 51 pins 128 N of clips in each coil including 230 gm / sqm zinc coating on core complete all as specified and directed.
S&F for framed work with ornamental and intricate design as in doors or gate of angle or other section with gusset plates, rails, braces,etc complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive steel sheeting or other covering running rails and guides ) and hanging also fastening and fixing complete with rolled mild steel conforming to Fe.290 Gde-E-165.
S&F 0.80 mm mild steel,plain,black sheet in wall clading,steel gates and similar work;cut to size,holes punched;including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams,including bending or turning up,mitred angles,etc as required complete all as specified and directed.
M & L for two coats of synthetic enamel paint over & including a coat of red oxide primer on new steel and iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
M & L for Rendering 15 mm thick in CM 1:4 on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed.
All as above but for surfaces other than fair face of brick work or on one side lathing
Applying two coats of cement base paint over one coat of cement primer including preparation of surface etc. Complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 mm thick complete all as specified and as directed.
Removing excavated material in exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point in soft/soil all as specified and directed.
Demolition of brick wall built in cement mortar or cement lime mortar
Supply, installed, testing & commissioning split type air conditioner of capacity 1.5 TR, with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, star rated suitable for wall mounted,single phase, 230/250 volt AC with cooling and heating function including S & bracket for outdoor unit and breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning , making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed.Make VOLTAS/LG/ Carrier/Hitachi/Blue Star/Samsung.
Supply, installed, testing & commissioning refrigerator electric driven 230 V AC 50 Hz capacity 308/310 Ltrs frost free, double door 5 star rated.Make LG ,Model No GL-T322PRZM, or equivalent in KELVINATOR/ SAMSUNG.
Supply , installation , commissioning of water cooler partially stainless steel, electric driven single phase having approx storage capacity 150 Ltrs and nominal cooling capacity 150 Ltrs.Make :- Voltas/ Blue Star/LG/SRIRAM Usha
M & L for power/sub main wiring with two runs of single core 6 sqmm size and one run of single core 2.5 sqmm (green colour as earth continuty conductor ) FRLS PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 6 sq mm single core copper conductor, one run of 2.5 Sq mm copper conductor & PVC conduit shall be measured as one unit length.)
Supply & Fixing split type air conditioner of capacity 1.5 TR,three star rated with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, star rated suitable for wall mounted,single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning , making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed.
S & F earth plug enclosure (plug and socket ) with MCB, SP 20 Amps.
S & F MCB SPN 32 Amps 240 volts in existing MCB DB .
S & F Factory made,universal bracket / wall mounting stand ,made with galvanized structural steel,high strenth,weather proof,powdeer coated,modular construction and not less than 5 Kg and suitable upto 2 TR capacity split type AC.
S & F wall mounted voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 140 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 5 KVA complete all as specified and directed. Make V Guard , Model No. VND - 500 or equivalent in Bluebird / AE/Microtech or any other sample approved by GE.
S & F auto change over unit with inbuilt timmer (programmable for operation between 01 hour to 24 hrs) having facility to operate alternatively two AC upto capacity 2.0 TR , commissioning and testing complete all as specified.
Cutting holes for gate in brick masonry walls built in cement mortar, panneled with plywood for inserting hold fasts, depth of embedded portion of hold fast exc 10 cm and n.exc 20 cm and making good in CM 1:3 including finishing to wall complete to match with the adjoining existing surface as directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete as specified & directed.
S&F unplasticised poly vinyl chloride coated (UPVC), pristine white colour, readymade window fixed woth fasterner contaning glazing and weather seal glass to be used double in 6mm thick clear glass with 12mm argon gas gap half fixed half openable of area exc 2 sqm but n exc 4 sqm each with and including necessary accessories as per manufacture's instructions complete all as specified and directed. Make:- Fenesta/Wintech .
Supplying,installation,testing,commissioning of LT panel board 3 phase 4 wire system outdoor type factory made free standing,floor mounting with suitable PCC foundation dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finnaly plyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip all as specified for the following:- (a) Incomming :- (i) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-400 Amp with CT's - 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Aluminium bus bar rating 300 Amps 3 phase neutral-01 set (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 Amps 16 KA 415 Volts 4 pole -03 Nos.
M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 4.00 M deep below GL with top edge of plate not less than 3.00 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mm and RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed.
Supplying,installation,testing & commissioning of LT panel board 3 phase 4 wire system outdoor type factory made free standing,floor mounting with suitable PCC foundation dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finnaly plyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip all as specified for the following:-. (a) Incomming :- (i) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -01 No. (ii) Digital type amp meter 0-400 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Copper bus bar rating 300 Amps 3 phase neutral-01 set (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCCB 100 Amps 25 KA 415 Volts 4 pole -02 Nos. (ii) MCCB 63 Amps 35 KA 415 Volts 4 pole -03 Nos.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in sof/loose soil as specified and directed.
M&L Hardcore of broken stone and boulders guage exc 63mm but n exc. 100 mm, deposited,spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surfaceas complete all as specified and directed.
M&L 100 mm thick Cement concrete type C-2,1:4:8 (40mm graded crushed stone aggregate) as in sub base of floor and paving all as specified and directed.
M&L 100 mm thick Cement concrete type B- 2,1:2:4 (40mm graded crushed stone aggregate) as in floor finishing the surface even and smooth with using extra cement.
M&L for PCC type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) for bed blocks and similar work as specified.
M&L steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS .1161-1979 grade St -240
S&F Roof trusses (framed), trussed, purlines, crane gantries, rails and fastenings and heavy bracket framing (Beam,tee angle,channel or flat sections) including distance pieces, cleats all as specified and directed.
S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of colour having tensile strengh of 550 Mpa as in roof covering /cladding to wall , fixed with self toping screws as specified
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor FRLS cable as earth continuity conductor and connected to common earth dolly, including metal flush box fabricated steel terminal box made out of 1.60 mm thick MS sheet concealed in walls, with modular white cover plate with frame for housing the switches, socket outlets, fan regulators with rigid non metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of 25mm dia, junction box 1 to 4 way suitable for 25mm dia conduit on high quality of acrylic/sunmica sheet to match the wall panelling in the building for installation of lights/project or any equipment., all as specified and as directed for One light/fan point controlled by one switch
All as per item above but one bell /buzzer point controlled by one push button independent.
All as per item above but one 3 pin switch socket outlet point 5 Amps on independent board
All as per item above but one 3 pin switch socket outlet point 5 Amps on same board.
All as per item above but 2.5 sqmm single core PVC insulated and unsheathed FRLS cable multistranded copper conductor for one 3 pin socket outlet 15 Amps on independent board.
S&F switch piano flush type single pole one way 5 Amp.
S&F electronic stepped type fan regulator.
S&F ceiling fan AC single phase 230 /240 Volts of size 1200 mm sweep, BEE 5 star rated and conneting up electrically including provision of cable from ceiling rose to connector or to the fan.Make:- Usha/Havells/orient/Luminous
S&F looking mirror size 135 cm x 400mm x 5mm thick mounted on10mm thick BWR ply wood and 20mm teak wood beading all around including necessary fixing acessories to fix in wall all as specified and directed. Make- Autal/Modigurd/Saint Gobin.
S&F 20mm dia alumnium curtain rod (Dropery rod) with coloured plastic coated fancy type nickle polished golden or silve colour as per samplecomplete all as specified as directed.
S&F coloured PVC coated fancy type brackets matching colour for fixing of 20mm dia dropery rod complete all as specified and directed.
S&F fancy type Knob nickle polished golden or silve colour for fixing of 20 mm dia dropery rod complete all as specified and directed.
M&L for point wiring with 4.0 sqmm FRLS PVC insulated and unsheathed copper cable 1100 volts grade stranded copper conductor cable drawn through and including PVC conduit conforms to IS: 9537 (Par-3) and ISI marked not less than 25 mm dia with concealed wiring system complete with all fittings and acessories including GI box of thickness 2.0 mm and hylem sheet cover of 3 mm thick for mounting of switches, sockets, regulators, etc and 4.0 sq mm stranded FRLS PVC insulated and unsheathed copper cable for earth continuity for one 3 pin socket outlet, 15 Amps on independent board for fixing single pole and neutral enclosure with a two pin and earth plug with socket with one single pole MCB. complete all as specified and directed.
S&F socket combination 3/6 pin 5/15 Amp universal type.
S&F MCB SP 6 to 32 Amps C curve 240 volts.
S&F steel water tubing 15 mm bore medium grade galvanized with all fittings such as bends, tees, nipples, elbows, reducers, etc, fixed complete to walls and ceilings or laid in floors all as specified and directed.
All as per item above but 20 mm dia.
S&F 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe all as specified and directed. Make- Essco or equivalent
Cutting holes into or through brick wall built in cement morter and making good in cement morter 1:3 or cement concrete 1:2:4 type B-1 as required, superficial area exc 150 Sqcm but nexc 400 sqcm.
S&F ceiling rose surface backlite 65X50 mm two to three terminals complete.
S&F exhaust fan AC single phase metallic 230 V of size 230 mm sweep Make:-Havells VentilairDSP or equivalent in BajajCrompton Greaves .
Ecxavation in post holes (or similer holes) each not exc 0.5 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm and getting out in soft/loose soil.
SOIL INVESTIGATION: Soil invenstigation as specified in PS (Depth of Bore 10 M) for following Bluildings at AF Station Gorakhpur :- (a) construction of multistory OTM Accn for LGS SEC and IMMLOS Server at AF Stn Gorakhpur. (b) OTM Accn for CBRN & SITC at AF Station Gorakhpur . (c) Pvon of fir exit ladder around SRE building at 17 Wing AF Stn Gorakhpur. Note :- (i) Any other info required shall also be furnished by soil Testing agency without extra cost. (ii) Quantity catered is tentative any may vary at the time of actual execution (iii) The quoted rates shall be inclusive of transportation loading unloading labour charges for each test for single instance including complete machinery, in case of repetition of test additional charges for transportation loading unloading labour charges etc shall not be adimissible. (iv) Soil investigation mentioned at S No. 67 and 68 of BOQ shalll be executed at AF Gorakhpur Station as specified in praticular specification under heading soil insvestigation. (v) Contractor's may quote rate considring above facts (vi) The work may be carried to bldg for OTM Accn for CBRN & SITC as per site requirement. (vii) Soil test result for above all the three buildings mentioned at (a), (b) & (c) shall be given in seprate folder in sextruplicate for each building.
SOIL INVESTIGATION: Soil invenstigation as specified in PS (Depth of Bore 6.0 M) for following Bluildings at AF Station Gorakhpur :- (a) construction of multistory OTM Accn for LGS SEC and IMMLOS Server at AF Stn Gorakhpur. (b) OTM Accn for CBRN & SITC at AF Station Gorakhpur . (c) Pvon of fir exit ladder around SRE building at 17 Wing AF Stn Gorakhpur. Note :- (i) Any other info required shall also be furnished by soil Testing agency without extra cost. (ii) Quantity catered is tentative any may vary at the time of actual execution (iii) The quoted rates shall be inclusive of transportation loading unloading labour charges for each test for single instance including complete machinery, in case of repetition of test additional charges for transportation loading unloading labour charges etc shall not be adimissible. (iv) Soil investigation mentioned at S No. 67 and 68 of BOQ shalll be executed at AF Gorakhpur Station as specified in praticular specification under heading soil insvestigation. (v) Contractor's may quote rate considring above facts (vi) The work may be carried to bldg for OTM Accn for CBRN & SITC as per site requirement. (vii) Soil test result for above all the three buildings mentioned at (a), (b) & (c) shall be given in seprate folder in sextruplicate for each building.
Takingdown copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittingsetc. Removing materials and making good disturbed surfaces of walls, floors etc
Taking down carefully unserviceable sub main wiring including conduit/casing patti etc.
Taking down unserviceable DBs any type carefully disconnecting and making good disturbed surfaces complete all as directed.
Taking down unserviceable MCB SP/SPN/Isolator of any rating & size.
S&F modular switch1 way 6A, 1 module
S&F modular switch1 way 16A, 1 module
S&F modular socket out let 6A 2/3 on combined 2 module
S&F modular socket out let 6A/16A-2/3 pin combined 2 module
S&F modular bell push 6 Amp, 01 module.
S&F call bell multi music type.
S&F modular fan step regulator electronic 2 modular type volts AC 50 HZ ,120 Watts,4step complete all as directed.
S&F SKY LUX LED 36 watt recess mounting 2x2 luminaire white poeder coated CRCA housing with high powder LEDs .Aluminium front frame with flat white high transmission acrylic cover with complete accessories all as specified and directed by engr-in charge.MAKE- BAJAJ CAT NO112642-BZRSQL 36WGZ1 WH
S&F MCB DB TPN 4 ways,with metal double door ,IP -43 protection suitable for MCB as incommer and MCB as out going,VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link of complete including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e directed by Engr-in charge.Make :Indo asian /ABB/Siemens/Merlin Gerin
S&F sheet metal enclosure distribution board SPN, 12 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including cutting chases to wall for fixing of DB. , Make - Indo asian or equivalent in ABB/ Siemens
S&F MCB Tripple pole and neutral, C curve 415 volts, 63 Amps, all as specified and as directed. Make - Indo asian or equivalent in ABB/ Siemens
S&F sheet metal enclosure with earth plug and socket 2 pin with MCB DP 20 Amp, 240 V, single phase for AC all as directed by Eng-in-charge. Make - Indo asian or equivalent in ABB/ Siemens
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall all as directed by Eng-in-charge.
M&L Sub main wiring complete with 2 runs of 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 Volts with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit of dia not less than 25 mm including all accessories fixed on surface/wall celing etc including provision of 1 run of 2.5 Sqmm FRLS PVC insulated unsheathed Cable with multistranded copper conductor as earth continuity. Note:-Two runs of cable, one run of earth continuity conductor and one run of PVC conduit pipe shall be measured as one unit.
Disconneting and taking down the electrical connection of ceiling fan/wall mounting fan with fan from existing location and cleaning, oiling, greasing and painting to reuse the same complete if necessary as required at site.
Hanging only ceiling fan/wall mouting fan and conneting up electrically including provision of cable from ceiling rose or connector to fan.
S&F GI tubing medium grade of 20 mm dia using as a down rod of ceiling fan upto appropiate height from ground surface with nut, bolts and washers and welding if necessay at site to fitment the ceiling fan through out of false ceiling downward to floor complete which obtained from dismantling complete all as specified and directed by Engr-in-Charge.
Taking down of existing indoor unit of split type airconditioner from anywhere with capacity of 1.5 TR/2 TR by disconnecting electrical connection from AC box / voltage stabilizer and indoor unit by removing copper tubes and recover the gas in vaccume compressore for reused and PVC pipes and keep aside for refixing the same at the place as directed by Engr-in-charge after carry out False/Ceiling & wall panelling work complete.
Fixing only indoor unit of split type Air Conditioner electrically driven, 230V, AC, 50 Hz of capacity 2.0 TR with high wall mounted type fan coil unit (FCU) to be fitted on wall with rawl plugs including making holes for inlet / output in the wall and making good existing surfaces including insulation of tubing with expanded polyethylene foam indulation tubing and making necessary connections including M&L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection throuth voltage stabilizers. Note :- (a) Wiring between FCU and condensing unit shall be deemed to incl in the unit rates quoted. (b) Required length of suitable size copper tubing from FCU to condensing unit shall deem to be included in the unit rates quoted by the contractor. (c) Gas to be filled at appropriate level which is deemed to included in unit rate quoted.
Taking down of voltage stabilizer wall mounting for automatic operation single phase, input voltage between 170 V to 250 V with out put voltage stabilized 230 V with accuracy +/- 2.5% Volt and keep aside for refixing the same after carry out fallse ceiling & wall panelling work complete all as specified and directed at site.
Fixing only voltage stabilizer wall mounting for automatic operation single phase, input voltage between 170 V to 250 V with out put voltage stabilized 230 V with accuracy +/- 2.5% Volt complete all as specified and directed at site.
Supply, laying, commissioning and testing LT XLPE armoured cable with aluminium conductor of size 16 sqmm 4 core including cable lugs, jointing materials etc., laid on wall for saddling or laid through GI pipe complete.
M/S Satyam Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .