Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
Refer Docs
Closing Date
12 Apr 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EE(CD-III), MZ-137, Main Building, IIT DELHI.
Name of work - Converting stores in front of Block III into safety unit offices in academic area at IIT Delhi Sub Head - Civil and Electrical work
2021_IIT_625504_1
IITD/WORKS(SP-3446)/2021
Open Tender
Civil Works
Works
30 days
IIT Delhi, Hauz Khas, New Delhi
As per tender document
15 documents required · 15 mandatory
₹500
ragistrar IIT Delhi
Exempted
16 Apr 2021
5 Apr 2021
13 Apr 2021
5 Apr 2021
12 Apr 2021
5 Apr 2021
90 days
Amount
1) Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
1.1) All kinds of soil
1.1.1) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
2) Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
2.1) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
2.1.1) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
3) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
3.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
5) Centering and shuttering including strutting, propping etc. and removal of form for
5.1) Suspended floors, roofs, landings, balconies and access platform
5.2) Lintels, beams, plinth beams, girders, bressumers and cantilevers
6) Edges of slabs and breaks in floors and walls
6.1) Under 20 cm wide
7) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
7.1) Thermo-Mechanically Treated bars of grade Fe-500D or more.
8) Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
9) Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant andtransported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommendedproportions as per IS:9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge.
9.1) All works above plinth level upto floor V level
10) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
10.1) Cement mortar 1:4 (1 cement : 4 coarse sand)
11) Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
11.1) Cement mortar 1:4 (1 cement :4 coarse sand)
12) Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
12.1) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
13) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
13.1) Fixed to steel windows/ alumiunm windows by screws
14) Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
15) Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
16) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
17) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
18) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
18.1) Twin rubber stopper
19) Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
20) Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
20.1) 1.0 mm thick
21) Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
21.1) With 12 mm mild steel U beading / aluminium snap beading
22) Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways(vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits,switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
23) Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.
24) Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing ofnecessary butt hinges and screws and applying a priming coat of approved steel primer.
24.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
25) Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
26) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
26.1) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
27) Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
27.1) Size of Tile 600x600 mm
28) Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
29) GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
30) 12 mm cement plaster of mix :
30.1) 1:4 (1 cement: 4 coarse sand)
31) 15 mm cement plaster on the rough side of single or half brick wall of mix :
31.1) 1:4 (1 cement: 4 coarse sand)
32) 6 mm cement plaster of mix :
32.1) 1:3 (1 cement : 3 fine sand)
33) Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
33.1) Two or more coats on new work
34) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
35) Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.
35.1) For door/ window/ clerestory window
36) Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
37) Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
38) Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
39) Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
39.1) Of area 3 sq. metres and below
40) Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
41) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
42) Providing and fixing soil, waste and vent pipes :
42.1) 100 mm dia
42.1.1) Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
43) Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
43.1) 100 mm dia pipe
44) Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :
44.1) For 100 mm dia pipe
45) Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
45.1) 100 mm dia pipe
45.1.1) Sand cast iron S&S as per IS - 3989
46) Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
46.1) Up to 300 mm dia
47) Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :
47.1) 100 mm dia pipe
48) Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :
48.1) 100 mm diameter pipe
48.2) Supplying pig lead at site of work.
49) Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting oflead and making into blocks, including stacking of pipes at site lead up to 50 metre:
49.1) 100 mm diameter C.I. pipe
50) Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :
50.1) 100 mm diameter
51) Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
51.1) 100 mm diameter S.W. pipe
52) Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
52.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
53) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
53.1) For fixed portion
53.1.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
54) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
54.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
55) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item):
55.1) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
56) Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:
56.1) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto300 mm height including rounding of junctions of walls and slabs.
56.1.1) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer in-charge
56.1) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved qualityin top layer of plaster and finally finishing the surface with trowelwith neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
56.1) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
56.1.1) With average thickness of 120 mm and minimum thickness at khurra as 65 mm
57) Providing and Fixing factory made single extruded WPC (Wood Polymer Composite ) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhensive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms ) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), minimum compressive strength 50 N/mm , modulus of elasticity 850 N/mm and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note : stainless steel piano hinges / soft close clip on concealed hinges and necessary S.S screws shall be paid seperately)
57.1) 18 mm Thick
58) Providing and fixing factory made single extruded WPC (Wood Polymer Composite ) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm , modulus of elasticity 850 N/mm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with tainless steel screws etc. all as per direction of Engineer-In-Charge. (Note: stainless steel screws shall be paid seperately)
58.1) 6 mm Thick
59) Providing and fixing 10 mm thick non-asbestos multipurpose cement board reinforced with cellulose fiber manufactured through autoclaving process (high pressure steam cured) as per IS: 14862 of Everest industries Ltd or equivalent make, over the existing MS frame work ( to be paid in basic items) with 25 mm counter sunk ribbed hard screws @ 200m center to center.
60) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make of Wire: Havells / Finolex / KEI / RR Kabel / Polycab)
60.1) Group-C
61) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Make of Wire: Havells / Finolex / KEI / RR Kabel / Polycab)
62) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Make of Wire: Havells / Finolex / KEI / RR Kabel / Polycab)
63) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (Make of Wire: Havells / Finolex / KEI / RR Kabel / Polycab)
63.1) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
63.2) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
63.3) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
63.4) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
63.5) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
64) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel conduit/ FRPVC Trunking as required. (Make of Wire: Havells / Finolex / Polycab / KEI / RR Kabel)
64.1) 3 x 2.5 sq. mm
64.2) 3 x 4 sq. mm
65) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (Make of Wire: Havells / Finolex / Polycab/ Delton/ RR Kabel))
66) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Make: Legrand / Havells Crabtree / L&T /Wipro North West / Schneider / GM/Anchor Roma))
66.1) 5/6 A Switch
66.2) 15/16 A Switch
66.3) 3 pin 5/6 A socket outlet
66.4) 6 pin 15/16 A socket outlet
66.5) Telephone socket outlet
67) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make: Legrand / Havells Crabtree / L&T /Wipro North West / Schneider / GM/Anchor Roma)
67.1) 1 or 2 Module (75mmX75mm)
67.2) 3 Module (100mmX75mm)
67.3) 6 Module (200mmX75mm)
67.4) 12 Module (200mmX150mm)
68) Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Make: Legrand / Havells Crabtree / L&T /Wipro North West / Schneider / GM/ Anchor Roma)
69) Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. (Make: Legrand / Havells Crabtree / L&T /Wipro North West / Schneider / GM)
70) Information socket - category 6-UTP - 1 module (Make: Legrand / Havells Crabtree / L&T /Wipro North West / Schneider / GM/Anchor Roma)
71) Supply and installation of recess mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 36 Watts, Output lumens not less then 3300lm; CCT not less then 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20. (Make: Philips/Wipro/Havells/Panasonic/Bajaj/Crompton/Osram/Halonix)
72) Supply and installation of surface mounting LED batten luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitaible for operating voltage and frequency: 130-300 V AC, 50 Hz; wattage not more then 20 Watts, Output lumens not less then 1800lm; CCT not less then 6500K; Length 4 feet; Normal surge protection 2.5kV; Powe factor not less then 0.9; Minimum IP protection 20. (Make: Philips/Wipro/Havells/Panasonic/Bajaj/Crompton/Osram/Halonix)
73) Supply and installation of wall mounting fan 400 mm sweep, suitable for operation on 230V, 50 Hz, AC Supply with inbuilt speed regulator etc. complete as requird etc. as required. (Make :- Havells / Crompton / USHA / Bajaj / Orient) Colour of fan shall be finallized by Engineer-in-Charge)
74) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Make :- Havells / Atomberg / Bajaj / Orient / Cromption/USHA)
75) Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams, including painting the exposed portion of loop, all as per standard design complete.
76) Supply and Installation of 250 mm sweep exhaust fan PVC body with louver shutter suitable for operation on 230V, 50 Hz, AC supply in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Make: Havells/ USHA/ Bajaj/ Orient/Cromption))
77) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. (Make: Havells/ Beldon/ D-Link/ Polycab)
77.1) 1 run of cable
77.2) 2 run of cable
78) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
78.1) 8 way , Double door
78.2) 16 way, Double door
79) Supplying and fixing 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
80) Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
81) Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (matter: AC / Normal / Emergency Power) etc. as required . (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
81.1) Single Pole, 10A
81.2) Single Pole, 16A
81.3) Single Pole, 25A
81.4) Double Pole, 16A
81.5) Double Pole, 32A
82) Supplying and fixing following rating, double pole, 240 V, MCB 'C' Series in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
83) Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
84) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SPN, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells
85) Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Make: Siemens/ L&T / Schneider / Legrand/ ABB/ C&S/ Havells)
85.1) For 8 way, Double door SPN MCBDB
85.2) For 14/16 way, Double door SPN MCBDB
86) Supplying, Installation, testing & commissioning of energy efficient LED Bulk Head light equipped with high brightness LED and energy efficient electronic driver with following features:- 130-300 Vac, 50Hz, wattage not more then 10 Watts, efficancy not less then 110 Lm/W, CCT 5700K, Nominal surge protection 2.5 kV, Power factor not less then 0.9, Minimum IP protection 66 etc. as required. (Make: Philips/Wipro/Havells/Panasonic/Bajaj/Crompton/Osram/Halonix)
87) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Less Credit of dismantled materials
88) Old flush door shutter of various thickness and sizes with fitting etc.
89) M.S angle iron & M.S bar
90) Cast iron pipe (Old LA pipe)
BASU DEV ROUT SANITATION
M/s S.K.Industries
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .