Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC NAGAR PANCHAYAT PATHARDEVA DEORIA | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.2 L+₹31,876.79 (2.30%)Rejected-Finance GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹14.3 L+₹37,434.79 (2.70%)Rejected-Finance 4 BY 8 BLOCK H NEAR VIJAY CHOWK EAST DELHI DELHI 110051 | EAST DELHI | DELHI | 110051 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.5 L+₹1.6 L (11.6%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹16.1 L+₹2.2 L (15.7%)Rejected-Finance NOT FOUND | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
7 Dec 2022, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA
SPECIAL REPAIR TO ROLE EQPT BAY AND CERTAIN TOILETS OF BPS IN KATRE LOOP AT AF STN SIRSA
2022_MES_560876_1
GE/SRA/T-51 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) SIRSA
As per Tender and NIT
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹43,000
Yes
29 Dec 2022
2 Nov 2022
9 Dec 2022
2 Nov 2022
7 Dec 2022
16 Nov 2022
2 Nov 2022 - 9 Nov 2022
Amount
B/R WORKS
Dismantling wall and ceiling boards (fibre, pulp, insulation board / slabs / blankets) any thickness, including cover fillets all as specified and as directed.
Supply and fix Anodised aluminium snap grid frame work of size 605 mm x 605 mm for false ceiling complete all as specified and directed.
Supply and fix for hangers 4 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed by EIC.
Supply and fix for 10 mm thick gypsum board ceiling fixed over snap grid as per manufactures instructions complete all as specified and directed by EIC.
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified & as directed.
Supply and fix Steel rolling shutters, (Laths thickness 1.00mm) without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear operated type with bevel gear box and crank handle
Supply and fix Safety lever locks mild steel with 4 levers for rolling shutters complete as specified & directed by EIC.
Supply and fix Ball bearing for rolling shutters complete as specified & directed by EIC.
Taking down chowkats or frames with shutters (without taking off shutters) of any description exc 1.50 Sqm but n.exc 4 Sqm each all as specified and directed by EIC.
Taking down chowkats or frames with shutters (without taking off shutters) of any description n. exc 1.50 Sqm each all as specified and directed by EIC.
Supply & Fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified & directed by EIC.
Supply & Fixing Factory made solid PVC moulded shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in the frame at site as per specification and all as specified & directed by EIC.
Supply and fix anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L 12mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, complete all as specified and as directed by EIC.
Supply & Fixing 105 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and directed by EIC
M&L one coat of black bituminous paint over surfaces of any description wood, steel, iron, concrete, brick, stone, etc. exc. 10cm in width or girth complete all as specified.
Supply & Fixing 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match
Supply & Fixing 100mm long cold rolled, mild steel butt hinges medium weight complete all as specified and directed by EIC.
Supply & Fixing 200mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed by EIC.
All as per item No 19 hereinbefore but 150 mm long complete all as specified and directed by EIC.
Supply & Fixing 150 mm long extruded aluminium alloy handle fabricated type anodised complete all as specified and directed by EIC.
All as per item No 21 hereinbefore but 125 mm long
Supply & Fixing 250 mm aluminium alloy anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section etc complete all as specified and directed by EIC.
All as per item No 23 hereinbefore but 200 mm long.
M&L in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and as directed.
S & F Mortice lock 4 levers, vertical type, size 100 mm made of brass all as specified and as directed.
S & F in repairs Mortice lock 4 levers, vertical type, size 100 mm made of brass all as specified and as directed.
Supply and fixing in repairs 4.0 mm thick sheet glass ordinary quality and fixed with oil putty n. exc. 0.5 sqm in each pane all as specified and directed by EIC.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 290 Gde E-165 all as specified and as directed by EIC.
Supply & Fixing Mild steel plain black sheet 1.00mm thick as in covering to door shut ters; covering to door chowkats (frames); chullah hoods; ducts; etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed by EIC.
Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in bed block to hold fast, filling in pressed steel chowkat, etc and similar work including necessary formwork complete all as specified and directed by EIC.
Supply and fix Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply and fix Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete complete all as specified and as directed.
Material and labour for preparing new or previously untreated steel or iron surfaces of any description not otherwise described exc. 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Material and labour for old painted steel or iron surfaces of any description not otherwise described exc. 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by EIC.
M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick (square /rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm screed bedding in cm 1:6 as in floors
M&L glazed coloured ceramic tiles 450 x 300m x 7mm thick on vertical surfaces of walls as dado etc set and joined in neat cement slurry and pointed in white or coloured cement over and including 10mm thick rendering in cm 1:4
M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.18 sqm but n. exc, 0.38 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm screed bedding in cm 1:6 as in floors
All as item no 40 here in before but on vertical surface as skirting over and incl 10 mm thick rendering in CM 1:4
Demolition of cement concrete (un-reinforced) in floors and paving not exceeding 15 cm thickness below or above ground level complete all as specified and as directed by EIC.
M&L Machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed bedding in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in cm 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by EIC.
M&L RCC 1:2:4, Type B1, using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by EIC.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for formwork to provide fair finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Taking down cement plaster/terrazzo finish on wall of any description hacking for key scrubbing down with water including racking out joints.
Material and labour for rendering (Internal) 15 mm thick in CM 1:6 on fair faces of the brick masonry surfaces and finished even and smooth without using extra cement complete all as specified and directed by EIC.
Material and labour for rendering (External) 15 mm thick in CM 1:4 on fair faces of the brick masonry surfaces and finished even and smooth without using extra cement complete all as specified and directed by EIC.
Material and labour for 4mm thick asbestos cement plain building boards, fixed to walls with screws complete all as specified and directed by EIC.
M&L for preparation of old plastered/ unplastered surface of wall and applying one coat of oil bound distemper
M&L for preparation of newly plastered/unplastered surface of wall and applying two coats of oil bound distemper over a coat of primer over wall care putty
M&L for preparation of old plastered/ unplastered surface of ceiling and applying one coat of oil bound distemper
M&L for preparation of old undecorated plastered/onplastered surface of wall and applying one coat of white wash as in ceiling
M&L for preparation of newly plastered/unplastered surface of wall and applying two coats of cement base paint (Camouflage/plain pattern) over a coat of primer with alkali resistant priming paint
M&L for complete removal of old plastered/unplastered surface of wall and applying two coats of cement base paint (Camouflage/plain pattern) over a coat of primer with alkali resistant priming paint
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed by EIC.
Material and labour for brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 using old size bricks complete all as specified and directed by EIC.
S & F in repairs Rotational moulded polyethylene water storage tanks of capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I all as specified and directed by EIC.
Taking down steel tubing 20mm bore and connection including cleaning for re-fixing.
Taking down steel tubing 15mm bore and connection including cleaning for re-fixing.
S & F GI tubing 20mm bore medium graded with all fitting complete to walls and ceilings or laid in floors.
S & F GI tubing 15mm bore medium graded with all fitting complete to walls and ceilings or laid in floors.
Refixing old steel tubing 15/20mm bore and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by EIC
Cutting chasses pining in brick walls and making good to facings where reqd and pointing in cement mortar 1:3 to ends or edges of sun, shade, shelves or for concealed water tubing exc 10cm but not exc 20cm girth
S & F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed by EIC.
S & F in repairs 15mm bore stop valve, cast copper alloy screwed down, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by EIC.
S&F in repair bib taps 15mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by EIC.
S&F in repairs 15 mm dia fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F in repairs Vitreous China half stall urinals, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; also providing and fixing flush pipe of suitable dia and length.
S&F in repairs vitreous china wash down water closet pan (Padestral Pattern) white with 'P' or 'S' trap excluding flushing cistern and flush pipe
S&F in repairs PVC valve less, symphonic action type flushing cistern of 10 litre capacity, low level with including bend pipe and connection to WC, brackets complete including taking down cistern
S&F PVC connection 15mm size with PTMT nuts, length 450 mm
S&F 32 mm dia Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) suitable for fixing to WHB waste coupling in suitable length
S&F in repairs vitreous china wash basin white with flat back size 550x400 incl brackets and waste fitting brass chromium plated with long screwed shanks and fly nuts 32 mm dia
S & F in repairs brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge .
S&F in repairs soap Dish any type fixed to plugs with chromium plated brass screws.
S&F PTMT grating doom 125 mm dia with/without waste hole min. weight 40 gms.
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long.
M&L Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron
M&L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors
M&L of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors
Supply only ERW or Induction butt weld M.S. Square tube black conforming to IS 1161-1979 grade Yst 240.
E/M WORKS
Taking down Point Wiring any type including Batten/PVC casing caping / PVC Conduit (Light, Fan, Socket or Power) but Incld Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and as directed.
M&L Point Wiring for light/fan/Bell point with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing sunken box of 2-3 mm thickness (as per Site requirement) for mounting Modular switches Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly. complete all as specified and as directed. Note- Sunken box will be same make as approved modular itmes Cable- Havells/KEI conduit Make- Kalinga/Finolex/ARG
Ditto as item No 3 additional light/fan point on same circuit complete all as specified and as directed.
Ditto as item No 3 but for 6 Amp Socket Outlet on Independent Board , complete all as specified and as directed.
Ditto as item No 3 but for 6 Amp Socket Outlet on Same Board , complete all as specified and as directed.
Ditto as item No 3 but for 16 Amp Socket Outlet on Independant Board , with 4 sqmm,1100 Volts 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 4 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in including PVC CONDUIT complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in including PVC CONDUIT complete all as specified and as directed.
M&L Flame Proof Sub-main Wiring with 2-Runs of 4.0 Sqmm Single Core, Halogen Free Flame Retardant (FRLSH) insulated, multi-stranded, unsheathed 1100 Volt grade Copper Conductor Cable and 1-Run of 2.5 Sqmm Earth Continuity Wire of Single Core, Halogen Free Flame Retardant (FRLSH) insulated, multi-stranded, unsheathed, 1100 Volt grade Copper Conductor Cable (Green Colour), drawn in/through including ERW/GI /steel CONDUIT, complete all as specified and as directed.
M&L Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm Single Core, Halogen Free Flame Retardant (FRLSH) insulated, multi-stranded, unsheathed 1100 Volt grade Copper Conductor Cable and 1-Run of 4.0 Sqmm Earth Continuity Wire of Single Core, Halogen Free Flame Retardant (FRLSH) insulated, multi-stranded, unsheathed, 1100 Volt grade Copper Conductor Cable (Green Colour), drawn in/through including ERW/GI CONDUIT, complete all as specified and as directed.
S&F modular Switch 1 way 6 Amp, 1 module , complete all as specified and as directed. Make- Havells ( Crabtree) / Indoasian/HPL
S&F modular Switch 1 way 16 Amp, 1 module , complete all as specified and as directed. Make- Havells ( Crabtree) / Indoasian/HPL
S&F modular Socket Outlet 6 &16 Amp 2/3 pin combined 2 module, complete all as specified and as directed. Make- Havells ( Crabtree) / Indoasian/HPL
S&F modular Socket Outlet 6 Amp 2/3 pin combined 2 module, complete all as specified and as directed. Make- Havells ( Crabtree) / Indoasian/HPL
S&F Modular Bell Push Button 6 Amp, 1 modular suitable for Call Bell and , complete all as specified and as directed Make Havells/HPL/Indoasian
S&F Call Bell Electric Single Pole, 230 Volt, AC supply, Ding Dong type and , complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and Fixing-in-repairs, complete all as specified and as directed.
S&F Modular white plate frame 3 Module complete all as specfied and as directed by engineer-in-charge.
S&F Modular white plate frame 6 Module complete all as specfied and as directed by engineer-in-charge.
S&F Modular Metal flush box 3 Module complete all as specfied and as directed by engineer-in-charge.
S&F Modular Metal flush box 6 Module complete all as specfied and as directed by engineer-in-charge.
S&F Modular Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type and Fixing-in-repairs, complete all as specified and as directed.
S&F Slim linear LED lightening fixture 20 watt LED batten T5, with fullbase of extruded aluminium section as acting as a heat sink with closed back, isolated driver, CRI>70, PF>0.9 system efficacy >100 lm/watt, operating voltage 170-240 volts, colour Temp 6500K, low heat generating LED ( Make of LED shall be Cree/Nechia/Osram) complete all aconnection required using 1.5 sqmm copper conductor multistrandedpvc unsheathed 2 core flecible cable from ceiling rose to fitting complte all as required and directed Note- (i) The contractor shall obtain LM 79 & LM 80 reports for thelight fittings from manufacturer for the lotto be supplied and submite to department (ii) Any touch up of the wall surface due to changing of fitting shall be done by contractor with similar surfavce finish without extra cost to the department. Make- Havells ( E-lite) LED Pride Plus( cat Part No- LHEXBLP7PN1W020) or equivalent make in Philips/Polycab
S&F Slim linear LED lightening fixture 9/10 watt LED batten T5, with fullbase of extruded aluminium section as acting as a heat sink with closed back, isolated driver, CRI>70, PF>0.9 system efficacy >100 lm/watt, operating voltage 170-240 volts, colour Temp 6500K, low heat generating LED ( Make of LED shall be Cree/Nechia/Osram) complete all aconnection required using 1.5 sqmm copper conductor multistrandedpvc unsheathed 2 core flecible cable from ceiling rose to fitting complte all as required and directed Note- (i) The contractor shall obtain LM 79 & LM 80 reports for thelight fittings from manufacturer for the lotto be supplied and submite to department (ii) Any touch up of the wall surface due to changing of fitting shall be done by contractor with similar surfavce finish without extra cost to the department. Make- Havells ( E-lite) LED Pride Plus( cat Part No- LHEXBLP7PN1W020) or equivalent make in Philips/Polycab
S&F Slim linear LED lightening fixture 05 wattLED batten, with isolated driver, CRI>70, PF>0.9 system efficacy >100 lm/watt, operating voltage 170-240 volts, colour Temp 6500K, low heat generating LED ( Make of LED shall be Cree/Nechia/Osram) complete all aconnection required using 1.5 sqmm copper conductor multistrandedpvc unsheathed 2 core flecible cable from ceiling rose to fitting complte all as required and directed Note- (i) The contractor shall obtain LM 79 & LM 80 reports for thelight fittings from manufacturer for the lotto be supplied and submite to department (ii) Any touch up of the wall surface due to changing of fitting shall be done by contractor with similar surfavce finish without extra cost to the department. Make- Havells ( E-lite) LED Pride Plus( cat Part No- LHEXBLP7PN1W005) or equivalent make in Philips/Polycab
S&F Decorative Ultra Modern LED 42W 2x2 Panel light, recessed mounted panel comprising inbuilt occupancy with photo sensor including driver complete all as specified and as directed. MAKE : HAVELLS Cat No VENUSNEOHE 2x2R42 WLED 840SMARTPLUS or equivalent make in Polycab/ philips
S&F 10 watt LED Bulk Head , IP66 protection, surface mounted, hexagonal type, backlit LED luminare CRI>70, PF>0.9 system efficacy >100 lm/watt, operating voltage 170-240 volts, colour Temp 6500K, low heat generating LED ( Make of LED shall be Cree/Nechia/Osram) complete all aconnection required all as required and directed Note- (i) The contractor shall obtain LM 79 & LM 80 reports for thelight fittings from manufacturer for the lotto be supplied and submite to department (ii) Any touch up of the wall surface due to changing of fitting shall be done by contractor with similar surfavce finish without extra cost to the department. Make- Havells ( HEXA 10W) Cat Part No- HEXAFT10WLED857SSYMBOPC or equivalent make in Philips/Polycab
S&F MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 6 kA, 50 Hz including Connecting up and Fixing-in-repairs, complete all as specified and as directed.MAKE :Schneider,C&S/Indoasian/HPL
S&F MCB Single Pole & Neutral, 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 6 kA, 50 Hz including Connecting up and Fixing-in-repairs, complete all as specified and as directed. MAKE :Schneider,C&S/Indoasian/HPL
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 63 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes and Fixing-in-repairs, complete all as specified and as directed MAKE: Schneider,L&T,Indoasian./Havells
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 32 Amp, 240 Volt and Connecting up including Fixing-in-repairs, complete all as specified and as directed. Make- Schneider/havells
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
YESH BUILDERS
AGGARWAL CONSTRUCTION CO.
M/s Satguru Traders
shiv shanker enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .