| 1 | 1₹27.8 LAccepted-AOC | 1 | Accepted-AOC ok | |
| 2 | 2₹30.0 L+₹2.2 L (8.00%)Rejected-Finance 20 23 MANASKAMANA ROAD BANSBARI MORE PS ENGLISHBAZAR DT MALDA | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹31.2 L+₹3.4 L (12.2%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹35.5 L+₹7.7 L (27.7%)Rejected-Finance C O MANOJ KUMAR KESHRI MIRA SADAN ROAD NO 03 ANAND VIHAR NEAR WAXPOL FACTORY BOOTY MORE BUTI RANCHI JHARKHAND 834012 | RANCHI | RANCHI | JHARKHAND | 834012 | 4 | Rejected-Finance Not Lowest |
Tender Value
₹32.7 L
EMD Value
₹65,360
Closing Date
18 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
PROVN OF INDOOR BADMINTON COURT AT DIPATOLI MIL STN
2023_MES_590429_1
8000/1881/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹65,360
Yes
28 Jun 2023
20 Apr 2023
20 May 2023
20 Apr 2023
18 May 2023
4 May 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soils complete all as specified and directed.
Removing excavated soil/concrete beyound 5 km but n exc 15 km and and depositing where directed at level n exc 1.5 m above the starting point complete all as specified and directed.
M&L Plain cement concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundatins filling and mass concrete complete all as specified and directed.
M&L RCC (1:1 1/2:3) type A-1 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete compete all as specified and directed
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
Use and waste of formwork to sides and soffits of beams, lintels, chajja, shelves slabs including supports etc complete all as specified and directed.
M&L RCC (1:1 1/2:3) type A-1 using 20 mm graded stone aggregate for beams, lintels, chhajjas etc and the like complete all as specified and directed.
M&L for RCC (1:1 1/2:3) type A-1 (using 20 mm graded stone aggregate) as in columns, piers, pillars, posts and struts complete all as specified and directed.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel bars 6mm to 8 mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specifed and directed.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmen complete all as specified and directed.
S & F Mild steel bolts exc 12 mm and n exc 20 mm dia purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and directed.
M&L for two coat synthetic enamel paint on new steel surfaces over a coat of red oxide primer of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed.
M&L for cement plaster of 15 mm thick of 1:4 on fair faces of brick work or concrete surfaces on wall complete all as specifed and directed.
M&L for preparing old surfaces of walls and application of putty (any number of coats including smoothing using abrasive paper etc) and appling two coats of distemper oil emulsion over a coat of chalk whiting primer complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soil complete all as specified and directed.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for moorum/red bajri filling in foundations under floors or paving laid in layers n exc 30 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for 100 mm thick plain cement concrete type D2 1:4:8 (using 20 mm graded aggregates) complete all as specified and directed.
M&L for 40 mm thick plain cement concrete type B1 1:2:4 (using 20 mm graded granite stone aggregates) complete all as specifed and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in 1:6 CM complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C2 using 20 mm graded stone aggregate as in plinth protection complete all as specifed and directed.
Supplying, fabricating and fixing power coating of any colour (thickness or powder coatin not less than 50 micron), aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supplying, fabricating and fixing power coating of of any colour (thickness or powder coatin not less than 50 micron), aluminium door shutters, side hung type without sash bars. aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws, anodised aluminium fittings such as peg stays 150 mm long 1 nos, hinges type B21, 100 mm long 2 nos, suitable handle 1 nos complete all as specified and directed.
Supplying, fabricating and fixing power coating of of any colour (thickness or powder coatin not less than 50 micron), aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handle 2 nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
Anodised aluminium snap grid (anodised transprent or dyed to required shede according to IS: 1868 with minimum anodic coating of grade AC 15) of approved desion/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.
S&F 5.50 mm thick sheet glass ordinary quaility and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed.
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repairs brass chromium plated curtain rod 20 mm dia complete all as specified and directed.
S&F brass chromium plated curtain rod bracets for 20 mm dia complete all as specified and directed.
M&L in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed (ISI Marked) complete all as specified and directed.
S&F in repairs 3-4 mm thick, plan/designed (as approved by coptent authority), coloured aluminium composite panel as in wall cladding/roofing/paneling etc including necessary frame work and fittings and fixtures as per themanufacture's instructions complete all as specified and directed.
Supply and Installation of 4.5 mm sand finish BWF Approved pre-Game Line marking Badminton Court vinyl sport flooring playing area laid with suitable premium quality adhesiv 0.25 kg/sqm over the elastic base mat and jointed with PVC welding bar matching colour using hot air gun. 02. Supply and installation Non-Playing Area Badminton Court 4.5 mm Enlio Gem finish mat complete all as specified and directed.
Providind of Movable type Badminton post with tournament badminton net complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 44 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 44 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 44 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly complete all as specified and directed.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed complete all as specified and directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
M&L for submain complete with 2x2.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 2.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-53 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire.
Supply and fix MCB DB SPN 12 way double door with metal door suitabl for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed complete all as specified and directed at site.
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of incommer and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F MCB DP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F Environmental friendiy, enegry saving long life corrosion resistant, IP 66 protection, vertical surface mounting pressure die-cast aluminium housing (light engine) well glass liminaires with high power LED as light source of 70 watt complete all as specified and directed.
S&F LED building security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed.
S&F Energy saving environmental friendiy, long life, exclusive innovative die-cast aluminium IP 66 flood light, suitable for highlighting architectural facade and general purpose lighting of 210 watt complete all as specified and directed.
S&F LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed.
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M/s Mukesh and company
M/S Sweta Construction
M/S.R.S.Chauhan and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .