Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-Finance | L1 | Accepted-Finance Lowest rate quoted | |
| 2 | L2₹8.0 L+₹15,296 (1.94%)Rejected-Finance | L2 | Rejected-Finance Quoted rate not lowest | |
| 3 | L3₹8.1 L+₹19,056 (2.42%)Rejected-Finance | L3 | Rejected-Finance Quoted rate not lowest |
Tender Value
₹7.8 L
EMD Value
₹16,000
Closing Date
25 Sept 2020, 6:00 pmClosed
Superintending Engineer IV
Office of Superintending Engineer IV
Routine Breakdown maintenance and Fault rectification of Ash Water Recirculation System and Effluent Treatment Plant
2020_RVUNL_506278_1
T06/SE-IV/BTPS/CIMD-IV/2020-21
Open Tender
Electrical Works
Lump-sum
365 days
OTPS Obra
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Dy CAO CFA and BO BTPS OBRA SONEBHADRA
₹16,000
8 Oct 2020
29 Aug 2020
29 Sept 2020
29 Aug 2020
25 Sept 2020
29 Aug 2020
29 Aug 2020 - 25 Sept 2020
Amount
Routine checking & minor maintenance work of complete Electrical system installed in the AWRS & ETP. (01 Jobs per month)
Removal & Reinstallation/Replacement work of 0.4 KV, 130 KW rated Electrical motors of pumps installed in AWRS. a. Disconnection of 3 phase wiring (comprising star-delta starter connection) of motor and removal of motor from the pump. b. Replacement/Reinstallation of motor on the pump, checking of module, re-commissioning and trial run of motor.
Removal & Reinstallation/Replacement work of 0.4 KV, 30 KW Electrical motors of pumps installed in Effluent Treatment Plant. a. Disconnection of 3 phase wiring (comprising star-delta starter connection) of motor and removal of motor from the pump. b. Replacement/Reinstallation of motor on the pump, checking of module, re-commissioning and trial run of motor.
Removal & Re-installatio/Replacement work of 0.4 KV, 0.7KW to 5.5 KW Electrical motors of various small pumps installed in Effluent Treatment Plant. a. Disconnection of 3 phase wiring (comprising star-delta starter connection) of motor and removal of motor from the pump. b. Replacement/Reinstallation of motor on the pump, checking of module, re-commissioning and trial run of motor.
Servicing/preventive maintenance/ breakdown maintenance/ Replacement of Bearings, testing & trial run of 0.4 KV, rated upto 150 KW, Electrical motors installed in AWRS.
Servicing/preventive maintenance/ breakdown maintenance/ Replacement of Bearings, testing & trial run of 0.4 KV, 30 KW, Electrical motors installed in ETP.
Servicing/preventive maintenance/ breakdown maintenance/ Replacement of Bearings, testing & trial run of 0.4 KV, 0.7KW to 5.5 KW, Electrical motors. of various small pumps.
Servicing/Preventive maintenance/ Breakdown Maintenance testing of electrical modules of motors & incomer section upto 150 KW.
Work of Salvage/laying of L.T. power cable armoured PVC aluminium /copper conductor of sizes- 2C x 26 to 70 mm2 3C x 26 to 70 mm2 / 3.5C x 25 to 80 mm2
Work of End termination/Straight through Jointing/ Repair/Tapping of L.T. power cable armoured PVC Al/Cu conductor of sizes- 2C x 26 to 70 mm2 3C x 26 to 70 mm2 / 3.5C x 25 to 80 mm2
POWER ELECTRONICS CORPORATION
M/S Deen Dayal
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .